BS 7455-7-1992 Analysis of nickel alloys by flame atomic absorption spectrometry - Method for determination of aluminium《用火焰原子吸收光谱测定法对镍合金的分析 第7部分 铝含量的测定方法》.pdf
《BS 7455-7-1992 Analysis of nickel alloys by flame atomic absorption spectrometry - Method for determination of aluminium《用火焰原子吸收光谱测定法对镍合金的分析 第7部分 铝含量的测定方法》.pdf》由会员分享,可在线阅读,更多相关《BS 7455-7-1992 Analysis of nickel alloys by flame atomic absorption spectrometry - Method for determination of aluminium《用火焰原子吸收光谱测定法对镍合金的分析 第7部分 铝含量的测定方法》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS7455-7: 1992 ISO7530-7: 1992 Analysis of nickel alloys by flame atomic absorption spectrometry Part7: Method for determination of aluminium UDC 669.245:543.422:546.62BS7455-7:1992 This British Standard, having been prepared under the directionof the Non-ferrous Metals Standards Po
2、licy Committee, was published underthe authority of the Standards Board and comes intoeffect on 15 December1992 BSI12-1999 The following BSI references relate to the work on this standard: Committee reference NFM/10 Draft for comment91/41175DC ISBN 0 580 21422 2 Committees responsible for this Briti
3、sh Standard The preparation of this British Standard was entrusted by the Non-ferrous Metals Standards Policy Committee (NFM/-) to Technical Committee NFM/10, upon which the following bodies were represented: Association of Bronze and Brass Founders British Non-ferrous Metals Federation British Stee
4、l Industry Department of Trade and Industry (Laboratory of the Government Chemist) Engineering Equipment and Materials Users Association Institute of British Foundrymen London Metal Exchange Ministry of Defence Nickel Development Institute Non-ferrous Metal Stockists Stainless Steel Fabricators Asso
5、ciation of Great Britain Steel Casting Research and Trade Association Coopted members Amendments issued since publication Amd. No. Date CommentsBS7455-7:1992 BSI 12-1999 i Contents Page Committees responsible Inside front cover National foreword ii 1 Scope 1 2 Normative references 1 3 Principle 1 4
6、Reagents 1 5 Apparatus 1 6 Sampling and sample preparation 1 7 Procedure 2 8 Expression of results 3 9 Test report 3 Table 1 Nominal composition of test samples 3 Table 2 Results of statistical analysis 3 List of references Inside back coverBS7455-7:1992 ii BSI 12-1999 National foreword This Part of
7、 BS7455 has been prepared under the direction of the Non-ferrous Metals Standards Policy Committee. It is identical with ISO7530-7:1992 Nickel alloys Flame atomic absorption spectrometric analysis Part7:Determination of aluminium content, published by the International Organization for Standardizati
8、on (ISO). At present this British Standard consists of eight Parts all concerned with methods for flame spectrometric analysis of nickel alloys. Further International Standards are in preparation on the same subject and when available, these will be published as further Parts of this British Standar
9、d. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Cross-references International Standar
10、d Corresponding British Standard ISO5725:1986 BS5497 Precision of test methods Part1:1987 Guide for the determination of repeatability and reproducibility for a standard test method by inter-laboratory tests (Identical) ISO7530-1:1990 BS7455 Analysis of nickel alloys by flame atomic absorption spect
11、rometry Part1:1991 General requirements and sample dissolution (Identical) Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, pages1 to4, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments i
12、ncorporated. This will be indicated in the amendment table on the inside front cover.BS7455-7:1992 BSI 12-1999 1 1 Scope This part of ISO7530 specifies a flame atomic absorption spectrometric method for the determination of aluminium in the range of0,2%(m/m) to4%(m/m) in nickel alloys. Typicalcompos
13、itions of nickel alloys are given inAnnexB ofISO7530-1:1990. The general requirements concerning the apparatus, sampling, dissolution of the test sample, atomic absorption measurements, calculations and test report are given in ISO7530-1. 2 Normative references The following standards contain provis
14、ions which, through reference in this text, constitute provisions of this part of ISO7530. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this part of ISO7530 are encouraged to investigate the possibility of ap
15、plying the most recent editions of the standards indicated below. Members of IEC and ISO maintain registers of currently valid International Standards. ISO5725:1986, Precision of test methods Determination of repeatability and reproducibility for a standard test method by inter-laboratory tests. ISO
16、7530-1:1990, Nickel alloys Flame atomic absorption spectrometric analysis Part1: General requirements and sample dissolution. 3 Principle Dissolution of a test portion in acid, filtration and aspiration of the test solution into a nitrous oxide-acetylene flame of an atomic absorption spectrometer. C
17、ombustion of the filter from the acid dissolution and volatilization of silica with hydrofluoric acid. Fusion of the residue with potassium pyrosulfate, dissolution of the melt in dilute acid and aspiration of this second solution into a nitrous oxide-acetylene flame of an atomic absorption spectrom
18、eter. Measurement of the absorbance of the resonance line energy from the spectrum of aluminium and comparison with that of calibration solutions at a wavelength of309,3nm. Addition of the results found in both solutions. 4 Reagents In addition to the reagents listed in ISO7530-1, the following spec
19、ial reagents are required. 4.1 Hydrofluoric acid, 20 =1,15g/ml. WARNING Hydrofluoric acid is extremely irritating and corrosive to skin and mucous membranes, producing severe skin burns which are slow to heal. In the case of contact with skin, wash well with water and seek medical advice. 4.2 Potass
20、ium pyrosulfate (K 2 S 2 O 7 ), powder. 4.3 Potassium chloride (KCl), solution. Transfer48g of potassium chloride to a600ml beaker, dissolve in500ml of water and transfer to a1000ml one-mark volumetric flask. Make up to the mark with water and mix. 4.4 Aluminium, standard reference solution(1,000g/l
21、). Weigh, to the nearest0,001g,1,000g of aluminium metal of99,9% (m/m) minimum purity and transfer to a400ml beaker. Add a small drop of mercury,30ml of hydrochloric acid ( 20 =1,18g/ml) diluted1+1 and heat to complete dissolution. Filter the solution through a7cm rapid filter paper into a400ml beak
22、er. Wash the filter with100ml ofwarm water. Add85ml of hydrochloric acid ( 20 =1,18g/ml) to the filtrate, cool and transfer toa1000ml one-mark volumetric flask. Make up tothe mark with water and store in a polyethylene bottle. WARNING Mercury is highly poisonous and has an appreciable vapour pressur
23、e. It must be stored in strong, tightly closed containers. Liquid mercury must be transferred in such a manner that a spill can be contained and thoroughly cleaned up at once. CAUTION Discard the mercury in accordance with local regulations. 4.5 Aluminium, standard solution(100mg/l). Pipette100ml of
24、 the aluminium standard reference solution (4.4) into a1000ml one-mark volumetric flask and add90ml of hydrochloric acid ( 20 =1,18g/ml). Dilute to approximately800ml with water, cool, make up to the mark, mix and store in a polyethylene bottle. 5 Apparatus In addition to the apparatus specified in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS745571992ANALYSISOFNICKELALLOYSBYFLAMEATOMICABSORPTIONSPECTROMETRYMETHODFORDETERMINATIONOFALUMINIUM

链接地址:http://www.mydoc123.com/p-546816.html