1、Designation: F2379 04 (Reapproved 2016) An American National StandardStandard Test Method forEnergy Performance of Powered Open Warewashing Sinks1This standard is issued under the fixed designation F2379; the number immediately following the designation indicates the year oforiginal adoption or, in
2、the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method evaluates the energy consumption ofpowered open warewashing sinks.
3、The food service operatorcan use these tests to evaluate and select a suitable washingdevice and understand its energy consumption.1.2 This test method applies to powered open warewashingsinks (powered sinks) with the following characteristics: alarge main water sink with electrically powered water
4、pump(s)and multiple high flow water nozzles. The unit may include gasor electric heaters to maintain water temperature. These pow-ered sinks are designed to run for predetermined cycle durationand accommodate pots and pans of various shapes and sizes aswell as cooking utensils. They are intended for
5、 stand alone useand require little supervision. The powered sink will be testedfor the following (where applicable):1.2.1 Maximum energy input rate (10.2),1.2.2 Preheat energy consumption and duration (10.3),1.2.3 Idle energy rate (10.4),1.2.4 Pilot energy rate, if applicable (10.5), and1.2.5 Washin
6、g cycle energy consumption (10.6).NOTE 1This test method applies only to the powered portion of theunit. Other compartments (sanitizing, rinsing, and so forth) are notevaluated.1.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalco
7、nversions to SI units that are provided for information onlyand are not considered standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health pract
8、ices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D3588 Practice for Calculating Heat Value, CompressibilityFactor, and Relative Density of Gaseous Fuels2.2 ANSI Standard:2000 International Fuel Gas Code32.3 ASHRAE Documents:ASHRA
9、E Guideline 2 (RA90) Engineering Analysis of Ex-perimental Data4ASHRAE 1993 Fundamentals Handbook43. Terminology3.1 Definitions:3.1.1 powered open warewashing sink, or powered sink,nan all-purpose, stainless steel water sink with electricallypowered water pump(s) and multiple high flow water nozzles
10、designed for cleaning pots, pans, and utensils. The mainwashing sink holds 60 to 100 gal of heated water. The unit mayor may not feature a scrapper sink, rinse tank, sanitizing tank,scrap table, or a drain table, or both.3.1.2 test method, na definitive procedure for theidentification, measurement,
11、and evaluation of one or morequalities, characteristics, or properties of a material, product,system, or service that produces test results.3.1.3 uncertainty, nmeasure of systematic and precisionerrors in specified instrumentation or measure of repeatabilityof a reported test result.3.2 Definitions
12、of Terms Specific to This Standard:3.2.1 energy input rate, npeak rate at which a poweredsink consumes energy (Btu/h or kW (kJ/h).1This test method is under the jurisdiction of ASTM Committee F26 on FoodService Equipment and is the direct responsibility of Subcommittee F26.06 onProductivity and Ener
13、gy Protocol.Current edition approved Oct. 1, 2016. Published November 2016. Originallyapproved in 2004. Last previous edition approved in 2010 as F2379 04 (2010).DOI: 10.1520/F2379-04R16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at servicea
14、stm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.4Available from American Society of Heating, Re
15、frigerating, and Air-Conditioning Engineers, Inc. (ASHRAE), 1791 Tullie Circle, NE, Atlanta, GA30329, http:/www.ashrae.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.2 idle energy rate, nthe rate of energy consumed(Btu/h or k
16、W (kJ/h) by the powered sink while holding ormaintaining a water-filled wash sink at the 115F (46C)setpoint.3.2.3 pilot energy rate, naverage rate of energy consump-tion (Btu/h) by a powered sinks continuous pilot (if appli-cable).3.2.4 preheat energy, namount of energy consumed by thepowered sink w
17、hile preheating the wash sink water from 70 65F (21 6 3C) to 115F (46C), with the control(s) set to acalibrated 115F (46C).3.2.5 preheat rate, naverage rate (F/min) at which thepowered sinks water is heated from 70 6 5F (21 6 3C) to115F (46C), with the control(s) set to a calibrated 115F(46C).3.2.6
18、preheat time, ntime required for the powered sinkwater to preheat from 70 6 5F (21 6 3C) to 115F (46C),with the control(s) set to a calibrated 115F (46C).3.2.7 washing energy, namount of energy consumed (Btuor kWh (kJ) during the powered sinks washing cycle.3.2.8 washing energy rate, naverage rate o
19、f energy con-sumption (Btu/h or kW (kJ/h) during the powered sinkswashing cycle.4. Summary of Test Method4.1 The powered sink under test is connected to the appro-priate metered energy supply. The measured energy input rateis determined and checked against the rated input beforecontinuing with testi
20、ng.4.2 The amount of cold (70 6 5F (21 6 3C) waterrequired to fill the main water sink to capacity is measured.4.3 The amount of energy and time required to preheat thepowered sinks wash sink from 70 6 5F (21 6 3C) to 115F(46C) is determined.4.4 The rate of idle energy consumption is determined with
21、the powered sink set to maintain 115F (46C) and the pumpmotor(s) switched off.4.5 Pilot energy rate is determined, when applicable, for gaspowered sinks.4.6 Washing cycle energy consumption is characterized fortwo different starting water temperatures: 70F (21C) and115F (46C).5. Significance and Use
22、5.1 The energy input rate test is used to confirm that thepowered sink is operating properly prior to further testing.5.2 Preheat energy and time can be useful to food serviceoperators to manage power demands and to know how quicklythe powered sink can be ready for operation when filled withcold wat
23、er.NOTE 2It is typically recommended that powered sinks be filled withhot water prior to use. This test is useful for operations that have a limitedsupply of domestic hot water and would need to use cold water to fill thesink to capacity.5.3 Idle energy rate and pilot energy rate can be used toestim
24、ate energy consumption during standby periods.5.4 Washing cycle energy consumption can be used by thefood service operator to estimate energy consumption duringoperating periods.6. Apparatus6.1 Barometer, for measuring absolute atmosphericpressure, to be used for adjustment of measured natural gasvo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF237920042016STANDARDTESTMETHODFORENERGYPERFORMANCEOFPOWEREDOPENWAREWASHINGSINKS 电动 开启 清洗 能量 性能 试验

链接地址:http://www.mydoc123.com/p-538550.html