ASTM UOP614-2018 Heptane or Toluene Insoluble Matter in Petroleum Oils Using Vacuum Filtration.pdf
《ASTM UOP614-2018 Heptane or Toluene Insoluble Matter in Petroleum Oils Using Vacuum Filtration.pdf》由会员分享,可在线阅读,更多相关《ASTM UOP614-2018 Heptane or Toluene Insoluble Matter in Petroleum Oils Using Vacuum Filtration.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、 IT IS THE USERS RESPONSIBILITY TO ESTABLISH APPROPRIATE PRECAUTIONARY PRACTICES AND TO DETERMINE THE APPLICABILITY OF REGULATORY LIMITATIONS PRIOR TO USE. EFFECTIVE HEALTH AND SAFETY PRACTICES ARE TO BE FOLLOWED WHEN UTILIZING THIS PROCEDURE. FAILURE TO UTILIZE THIS PROCEDURE IN THE MANNER PRESCRIB
2、ED HEREIN CAN BE HAZARDOUS. SAFETY DATA SHEETS (SDS) OR EXPERIMENTAL MATERIAL SAFETY DATA SHEETS (EMSDS) FOR ALL THE MATERIALS USED IN THIS PROCEDURE SHOULD BE REVIEWED FOR SELECTION OF THE APPROPRIATE PERSONAL PROTECTION EQUIPMENT (PPE). COPYRIGHT 1968, 1980, 2002, 2016, 2018 UOP LLC. All rights re
3、served. Nonconfidential UOP Methods are available from ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States. The UOP Methods may be obtained through the ASTM website, www.astm.org, or by contacting Customer Service at serviceastm.org, 610.832.9555 F
4、AX, or 610.832.9585 PHONE. Heptane or Toluene Insoluble Matter in Petroleum Oils Using Vacuum Filtration UOP Method 614-18 Scope This method is for the determination of either heptane or toluene insoluble material in petroleum oils. This method covers the range of 0.01 to 25 mass-% insolubles. Solid
5、 particulate materials interfere. More viscous or solid materials such as asphalts may be analyzed using this method but will require using a heated sonicating bath (up to 60C). The data provided by this method may be used as an index to coking tendency of petroleum oils when considering their suita
6、bility as charge stocks to cracking or other processes. Outline of Method A weighed sample is dispersed in ambient temperature solvent, either n-heptane or toluene, refluxed nominally at 80C for 2 hours, and filtered through a weighed glass microfiber filter using vacuum. Samples that cannot be comp
7、letely dispersed should not be analyzed by this method. The glass microfiber filter is dried at 100C and reweighed to obtain the weight of insoluble matter. Definition Asphaltenes are defined as the material present in oil fractions that is not soluble in light paraffinic solvents. They are fine, po
8、wdery, black-brown solids and are polymeric materials spanning a wide range of molecular weights. Their chemical composition is quite complicated. They appear to be closely associated with high molecular weight semi-polar naphthenic materials that require extended digestion time for separation. The
9、terms “heptane-insolubles”, “toluene-insolubles”, and “asphaltenes“ are often used synonymously. Apparatus References to catalog numbers and suppliers are included as a convenience to the method user. Other suppliers may be used, unless stated otherwise. Balance, readable to 0.0001 g Clamp, for ring
10、 stand and sample cylinders. minimum opening 38.1-mm, VWR International, Cat. No. C6088-12 Clamp holder, for ring stand and clamp, VWR International, Cat. No. C6088-2 Condenser, glass 300mm with 24/40 fittings, VWR, Cat. No. KT431500-2430 2 of 8 614-18 Cylinder, graduated, 250-mL, Fisher Scientific,
11、 Cat. No. 08-559EC Desiccator, to hold Petri dishes Dishes, Petri, borosilicate glass, 60-mm diameter, Fisher Scientific, Cat. No. 08-746A Electromantle with stirrer, 250ml, VWR, Cat. No. 33749-326 Filter apparatus (300-mL glass filter holder and 1-L filtering flask), VWR, Cat. No. KT953825-0000 Fin
12、denser, Heidolph Radleys, Model RR31100, 400mm long, Cat. No. 015610003 Flask, round bottom 250-mL with 24/40 fitting, VWR, Cat. No. 80068-778 Flask, Erlenmeyer, narrow neck, 250-mL, with penny head, ground-glass, standard taper stopper, Fisher Scientific, Cat No. 10-100E Forceps, stainless steel, w
13、ith flat, polished tips for handling filters, Millipore No. XX62 000 06 Hot plate, stirring, capable of 80C must have round base plate to work with Starfish Work Station, such as Heidolph MR Hei-Tec, Cat. No. 036110582 Oven, capable of operation at 100C Pipet, volumetric transfer, disposable, 2-mL,
14、Fisher Scientific, Cat. No. 13-650-2C Pump, vacuum, Welch Director Direct Drive Pump, Fisher Scientific, Cat. No. 01-115-4 Ring stand, with rectangular base, 140- x 229-mm with 610-mm rod, VWR International Cat. No. 470104-060 StarFish Work Station, Heidolph Radley, works with round-top stirring hot
15、 plates; includes base plate Cat. No. 015890020, monoblock for 250-mL flasks Cat. No. 015890070, rod support Cat. No. 015890410, 5-way clamp for Findenser Cat. No. 015892140 Stir bars, egg shape 1 inch x , VWR, Cat. No. 80062-140 Stir bar retriever, polyethylene, VWR, Cat. No. 80062-180 Tubing, Tygo
16、n, inch ID x inch OD, 1/16-inch wall, VWR International, Cat. No. 89403-882 Ultrasonic bath, heated, 1.5-L capacity, VWR, Cat. No. 89375-494 Wash Bottle, 500-mL, fluorinated HDPE, Fisher Scientific, Cat. No. 03-409-17B Reagents and Materials References to catalog numbers and suppliers are included a
17、s a convenience to the method user. Other suppliers may be used, unless stated otherwise. Desiccant, indicating Drierite, Fisher Scientific, Cat. No. 07-578-3A n-Heptane, 99% minimum purity, Honeywell Burdick there should be no sample left clinging to the bottom. If the sample is not completely disp
18、ersed, place the flask in the ultrasonic bath for 5 minutes. Use a ring stand and clamp to suspend the flask in the bath. Continue this procedure until the sample appears to be completely dispersed. The sample must be completely dispersed in the solvent or the test is invalid. 7. Place a stir bar in
19、 the flask, place flask into the monoblock which has been set on the hot plate, and connect the Findenser. Adjust the stir rate to maintain a moderate vortex, and set heating to achieve 80C, 5C. Apparatus set-up is pictured in Figure 1. An electromantle may also be used for heating/stirring, and wat
20、er-cooled condensers can be used in place of Findenser. See apparatus set-up in Figure 2. As a best practice use of an over-temperature device that will cut power if any of the positions exceed 100C is recommended. 8. Reflux the sample on the stirring hot plate for 2 hours. 9. Place a glass microfib
21、er filter disc (rough side up) in a clean, dry, previously numbered Petri dish and place both the petri dish and filter paper in the oven at 100C for 30 minutes to remove moisture. Remove from petri dish and filter paper from oven and place in a desiccator to cool. 10. Add about 180 mL of diluent so
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMUOP6142018HEPTANEORTOLUENEINSOLUBLEMATTERINPETROLEUMOILSUSINGVACUUMFILTRATIONPDF

链接地址:http://www.mydoc123.com/p-1244050.html