ASTM D6045-2004 Standard Test Method for Color of Petroleum Products by the Automatic Tristimulus Method《自动三色法测定石油产品颜色的标准试验方法》.pdf
《ASTM D6045-2004 Standard Test Method for Color of Petroleum Products by the Automatic Tristimulus Method《自动三色法测定石油产品颜色的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6045-2004 Standard Test Method for Color of Petroleum Products by the Automatic Tristimulus Method《自动三色法测定石油产品颜色的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6045 04An American National StandardStandard Test Method forColor of Petroleum Products by the Automatic TristimulusMethod1This standard is issued under the fixed designation D 6045; the number immediately following the designation indicates the year oforiginal adoption or, in the cas
2、e of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the automatic determination ofcolor of a wide variety of petroleu
3、m products such as undyedmotor and aviation gasoline, aviation turbine fuels, naphthas,kerosine, pharmaceutical white oils, diesel fuel oils, heatingoils, and lubricating oils by the automatic tristimulus method.This test method correlates to Test Method D 156 and TestMethod D 1500 as calculated by
4、the instrumentation.NOTE 1With the appropriate sample handling, this test method wouldapply to petroleum waxes, but they were not used in the round robin, andthe precision of this test method with regard to waxes is unknown.1.2 This test method reports results in terms of Test MethodD 156 or Test Me
5、thod D 1500.1.3 This test method has a one-to-one correlation for theentire range of Test Method D 1500 ASTM Color and for therange from 0 to +30 for Test Method D 156 Saybolt color.1.4 This test method does not apply to solid samples,petroleum products containing dye, and petroleum productshaving e
6、xtreme fluorescence.1.5 This test method does not apply to cloudy samples. Suchsamples shall be filtered so they are clear before measuring.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard t
7、o establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 156 Test Method for Saybolt Color of Petroleum Prod-ucts (Saybolt Chromometer Method)D 1500 Test Method for ASTM Color of Petroleu
8、m Prod-ucts (ASTM Color Scale)D 2500 Test Method for Cloud Point of Petroleum ProductsD 4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsE 284 Terminology of AppearanceE 308 Practice for Computing the Colors of Objects byUsing the CIE System2.2 Energy Institute Standard:IP 17 Dete
9、rmination of ColourLovibond Tintometer33. Terminology3.1 Definitions:3.1.1 ASTM colorthe name of an empirical scale ofexpressing of the color of a petroleum liquid darker thanSaybolt color based on a scale of 0.5 (lightest) to 8.0 Dil(darkest) and determined by Test Method D 1500.3.1.2 CIEthe abbrev
10、iation for the French title of theInternational Commission on Illumination, or CommissionInternationale de lEclairage. E 2843.1.3 CIE Standard Illuminant CColorimetric illuminant,representing daylight with a correlated color temperature of6774 K, defined by the CIE in terms of a relative spectralpow
11、er distribution. E 2843.1.4 CIE 1931 standard observerideal colorimetric ob-server with color matching functions x(l), y(l), z(l) corre-sponding to a field of view subtending a 2 angle on the retina;commonly called the “2 Standard Observer.” E 2843.1.5 Saybolt colorthe name of an empirical scale for
12、expressing of the color of a clear petroleum liquid based on ascale of 16 (darkest) to +30 (lightest) and determined by TestMethod D 156.3.1.6 tristimulus valuesThe amounts of three specifiedstimuli required to match a color.3.1.6.1 DiscussionIn the CIE system, they are assignedthe symbols X, Y, and
13、 Z. E 2844. Summary of Test Method4.1 The sample is poured into the glass sample container,and the container is placed into the light path of the automaticinstrument.Atransmittance measurement is performed in orderto determine the CIE tristimulus values (under CIE Standard1This practice is under the
14、 jurisdiction of ASTM Committee D02 on PetroleumProducts and Lubricants and is the direct responsibility of Subcommittee D02.05 onProperties of Fuels, Petroleum Coke and Carbon Material.Current edition approved Nov. 1, 2004. Published November 2004. Originallyapproved in 1996. Last previous edition
15、approved in 2002 as D 604502.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Methods for Analysis Testing, a
16、vailable from Energy Institute, 61 NewCavendish St., London, WIG 7AR, U.K.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Illuminant C and the CIE 1931 Standard Observ
17、er) of thesample in question. These are then converted instrumentally bythe appropriate algorithm to Saybolt color or ASTM colorvalues.4.2 The color of the sample is reported in eitherTest MethodD 156 or Test Method D 1500 values, as appropriate.5. Significance and Use5.1 Determination of the color
18、of petroleum products is usedmainly for manufacturing control purposes and is an importantquality characteristic because color is readily observed by theuser of the product. In some cases the color may serve as anindication of the degree of refinement of the material.When thecolor range of a particu
19、lar product is known, a variation outsidethe established range may indicate possible contamination withanother product. However, color is not always a reliable guideto product quality and should not be used indiscriminately inproduct specifications.6. Apparatus6.1 Either instrument described in 6.1.
20、1 or 6.1.2 may beused in this test method.6.1.1 SpectrophotometerThe spectrophotometer used inthe measurement shall satisfy the following specifications:6.1.1.1 Wavelength Range380780 nm.6.1.1.2 Effective Wavelength WidthThe effective wave-length width of the radiant flux from the slit of the spectr
21、o-photometer shall be 10 6 2nmor56 1 nm.6.1.1.3 Linearity60.5 % of full scale. Photometricreproducibility60.2 %.6.1.1.4 Wavelength Accuracy61 nm.6.1.1.5 Geometrical ConditionsNormal illumination andcollection. The illumination light flux shall not include a raywhich has an angle of five or more degr
22、ees toward the centralline. The angle of the center line inclination of the illuminationflux shall be 0 6 2 toward the normal line of the samplesurface.6.1.1.6 The spectrophotometer shall have the capability tocompute tristimulus values (CIE XYZ) using CIE StandardIlluminant C and the CIE 1931 Stand
23、ard Observer.6.1.1.7 A spectrophotometer that gives results comparableto those of the instrument described in 6.1.1.1 through 6.1.1.6shall be satisfactory.6.1.2 Tristimulus Filter ColorimeterInstrument designedfor high precision color measurement of clear liquids. Theinstrument shall be capable of c
24、onverting the light transmittedby a sample (under normal illumination/normal detection) intotristimulus values (CIE XYZ) using the CIE Standard Illumi-nant C and the CIE 1931 Standard Observer using PracticeE 308. A correlation between measured tristimulus values andTest Method D 1500 and Test Metho
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD60452004STANDARDTESTMETHODFORCOLOROFPETROLEUMPRODUCTSBYTHEAUTOMATICTRISTIMULUSMETHOD 自动 三色 测定 石油

链接地址:http://www.mydoc123.com/p-521379.html