ASTM UOP791-2016 Sulfur Components in LPG Fractions by GC-SCD《气相色谱-硫化学发光检测法测定液化石油气组分中的硫组分》.pdf
《ASTM UOP791-2016 Sulfur Components in LPG Fractions by GC-SCD《气相色谱-硫化学发光检测法测定液化石油气组分中的硫组分》.pdf》由会员分享,可在线阅读,更多相关《ASTM UOP791-2016 Sulfur Components in LPG Fractions by GC-SCD《气相色谱-硫化学发光检测法测定液化石油气组分中的硫组分》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、 IT IS THE USERS RESPONSIBILITY TO ESTABLISH APPROPRIATE PRECAUTIONARY PRACTICES AND TO DETERMINE THE APPLICABILITY OF REGULATORY LIMITATIONS PRIOR TO USE. EFFECTIVE HEALTH AND SAFETY PRACTICES ARE TO BE FOLLOWED WHEN UTILIZING THIS PROCEDURE. FAILURE TO UTILIZE THIS PROCEDURE IN THE MANNER PRESCRIB
2、ED HEREIN CAN BE HAZARDOUS. SAFETY DATA SHEETS (SDS) OR EXPERIMENTAL SAFETY DATA SHEETS (ESDS) FOR ALL OF THE MATERIALS USED IN THIS PROCEDURE SHOULD BE REVIEWED FOR SELECTION OF THE APPROPRIATE PERSONAL PROTECTION EQUIPMENT (PPE). COPYRIGHT 1980, 1994, 2013, 2016 UOP LLC. All rights reserved. Nonco
3、nfidential UOP Methods are available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, USA. The UOP Methods may be obtained through the ASTM website, www.astm.org, or by contacting Customer Service at serviceastm.org, 610.832.9555 FAX, or 610.832.9585 P
4、HONE. Sulfur Components In LPG Fractions by GC-SCD UOP Method 791-16 Scope This method is for determining trace amounts of sulfur species in liquefied petroleum gases (LPG) streams using a gas chromatograph equipped with a sulfur chemiluminescence detector (GC-SCD). Individual components are determi
5、ned quantitatively from 0.1 to approximately 200 mass ppm sulfur. Higher concentrations of sulfur may be measured by modifying the instrument conditions to accomodate the increase in signal. Reference ASTM Practice D 1265, “Sampling Liquified Petroleum (LP) Gases (Manual Method),” ASTM Practice D 52
6、87, “Automatic Sampling of Gaseous Fuels,” ASTM Method D6667-14, “Standard Test Method for Determination of Total Volatile Sulfur in Gaseous Hydrocarbons and Liquefied Petroleum Gases by Ultraviolet Fluorescence” ASTM Method D6849-13, “Standard Practice for Storage and Use of Liquefied Petroleum Gas
7、 (LPG) in Sample Cylinders for LPG Test Methods” UOP Method 516, “Sampling of Gasolines, Distillate Fuels and C3-C4 Fractions” UOP Method 999, “Precision Statements in UOP Methods,” www.astm.org Outline of Method A reproducible sample volume is introduced into a gas chromatograph equipped with a fus
8、ed silica capillary column internally coated with methyl silicon, sulfur chemiluminescence detector (SCD) and control and quantitation software. The SCD is sulfur specific and responds to all sulfur compounds on an equimolar basis. The mass-ppm sulfur concentration of each sulfur component in an LPG
9、 sample is calculated using the gas chromatographic external standard method of quantitation. The total sulfur is then verified via ASTM method D6667. Apparatus References to catalog numbers and suppliers are included as a convenience to the method user. Other suppliers may be used. Chromatographic
10、column, 40 m x 0.32 mm ID fused silica capillary, Agilent J&W DB-Sulfur SCD, G3903-63002 2 of 9 791-16 Clamp, for ring stand and sample cylinders. minimum opening 38.1-mm, VWR International, Cat. No. C6088-12 Clamp holder, for ring stand and clamp, VWR International, Cat. No. C6088-2 Cylinder, for s
11、ample collection Sulfinert coated, DOT 3E 1800, 500 mL capacity, Restek Cat. No. 24133, Equip with two sulfinert valves, Restek Cat No. 21400, and 6900 kPa gague (1000 psi) Gas chromatograph, temperature programmable, built for capillary column chromatography utilizing a split injection system havin
12、g a deactivated glass injection port insert and equipped with a sulfur chemiluminescence detector (Agilent Model 8355 or equivalent) that will give a minimum peak height response of 10 times the background noise for 0.1 mass-ppm of a sulfur peak when run under recommended conditions Regulator, air,
13、two-stage, high purity, Matheson Trigas, Model 3810A-590 Regulator, hydrogen, two-stage, high purity, Matheson Trigas, Model 3810A-350 Ring stand, with rectangular base, 140- 229-mm with 610-mm rod, VWR International, Cat. No. 470104-060 Tubing, Sulfinert Treated, 1.59-mm (1/16-inch) OD, 0.030 mm ID
14、, Restek, Cat. No. 29230 Tubing, translucent, FEP Teflon, 3.2-mm (1/8-inch) OD, 1.6-mm (1/16-inch) ID, 3450 kPa (500 pisg), Thomas Scientific, Cat. No. 9567K20 Valve, injection, 2.0-L internal sample volume injector, stainless steel, UWP series, with 1.59-mm (1/16-inch) fittings, manual with standof
15、f, Valco Instruments, Cat. No. 2CI4UWE2 Valve, metering, 3.175-mm (1/8-inch), straight, stainless steel, Swagelok, Cat. No. SS-ORS2-V Reagents and Materials References to catalog numbers and suppliers are included as a convenience to the method user. Other suppliers may be used. Air, zero-gas Blend,
16、 LPG, calibration, certified standard, sulfur species in known concentrations in isobutane, size No. 3 treated aluminum cylinder, with eductor tube, pressurized with an inert gas to 1437 kPa gauge (210 psig), Matheson Gas Products (required for analysis of LPG streams). The calibration blend life is
17、 certified for 12 months by Matheson Gas Products The blend must be monitored regularly and replaced when changes in concentration or species present are noted. Gas Purifier, hydrogen, to remove oxygen and moisture from carrier gas, VICI Metronics, Cat. No. P200-1 Gas purifier, air (for detectors),
18、VICI Metronics, Cat. No. P400-1 Hydrogen, zero-gas, 99.95% minimum purity Procedure The analyst is expected to be familiar with general laboratory practices, the technique of gas chromatography, and the equipment being used. Dispose of all used reagents, materials, and samples in an environmentally
19、safe manner according to local regulations. 3 of 9 791-16 Sampling Obtain the sample by following the procedures described in ASTM Practice D 1265, “Sampling Liquified Petroleum (LP) Gases (Manual Method),” ASTM Practice D 5287, “Automatic Sampling of Gaseous Fuels,” UOP Method 516, “Sampling and Ha
20、ndling of Gasolines, Distillate Fuels, and C3-C4 Fractions,” or other reliable technique. Analysis must be performed as soon as possible after sampling to minimize sulfur adsorption on cylinder walls, and to minimize reactions that produce changes in the composition of sulfur compounds in the cylind
21、er. Cylinders must be lined with a Sulfinert coating to further prevent sulfur adsorption onto the cylinder walls. Chromatographic Technique 1. Install a gas purifier between the carrier gas source and the carrier gas inlet on the gas chromatograph Column life is signifigantly reduced if the gas pur
22、ifier is not used 2. Install the fused silica capillary column in the gas chromatograph according to the manufacturers specifications. 3. Install the injection valve in the carrier gas line just ahead of the injection port and connect the valve ports according to the manufacturers instructions (Figu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMUOP7912016SULFURCOMPONENTSINLPGFRACTIONSBYGCSCD 色谱 硫化 发光 检测 测定 液化 石油气 组分 中的 PDF

链接地址:http://www.mydoc123.com/p-540830.html