ASTM F1842-2002 Standard Test Method for Determining Ink or Coating Adhesion on Plastic Substrates for Membrane Switch Applications《测定薄膜开关的塑料基质上油墨或涂层粘附的标准试验方法》.pdf
《ASTM F1842-2002 Standard Test Method for Determining Ink or Coating Adhesion on Plastic Substrates for Membrane Switch Applications《测定薄膜开关的塑料基质上油墨或涂层粘附的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1842-2002 Standard Test Method for Determining Ink or Coating Adhesion on Plastic Substrates for Membrane Switch Applications《测定薄膜开关的塑料基质上油墨或涂层粘附的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1842 02Standard Test Method forDetermining Ink or Coating Adhesion on Plastic Substratesfor Membrane Switch Applications1This standard is issued under the fixed designation F 1842; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is based on existing Test MethodD 3359, with modifications to make it suita
3、ble for plasticsubstrates and membrane switches.1.2 Despite the problems associated with a tape test onplastic substrates, it is our belief that this is still one of the bestways to test ink and coating for adhesion for membrane switchapplications. In writing this test method we are addressingsevera
4、l of the objections to the test method that could affect itsprecision and repeatability on plastic substrates.1.3 These test methods cover whether the adhesion ofcoating or ink to a substrate is at an acceptable level. They donot distinguish between higher levels of adhesion, for whichmore sophistic
5、ated methods of measurement may be required.NOTE 1It should be recognized that differences in adherability of theink or coating surface can affect the results obtained with inks or coatingshaving the same inherent adhesion.1.4 In multicoat systems adhesion failure may occur be-tween coats, so that t
6、he adhesion of the coating system to thesubstrate is not determined.1.5 This test method is specifically designed for measuringadhesion of inks and coatings (films) that have a thickness of5 mil (125 microns) or less, on plastics such as polyester andpolycarbonate.1.6 This standard does not purport
7、to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:D 3359 T
8、est Methods for Measuring Adhesion by TapeTest23. Terminology3.1 membrane switcha momentary switching device inwhich at least one contact is on, or made of, a flexiblesubstrate.4. Summary of Test Method4.1 A lattice pattern with six cuts in each direction is madein the ink or coating to the substrat
9、e. Pressure sensitive tape isapplied over the lattice and then removed, and adhesion isevaluated by comparison with the descriptions and illustra-tions.5. Significance and Use5.1 If the ink or coating is to fulfill its function, it mustadhere to the substrate. Substrates and their surface preparatio
10、nhave a significant effect on the adhesion of inks or coatings.Therefore, a method of evaluating adhesion of inks or coatingsto different substrates or surface treatments, or of different inksor coatings to the same substrate and surface treatment, isuseful to the industry.5.2 The limitations of all
11、 adhesion methods and the specificlimitation of this test method to lower levels of adhesion shouldbe recognized before using it. The intra and interlaboratoryprecision of this test method is under evaluation.5.3 Printing area to be tested should be a solid area largeenough to include the entire cro
12、ss hatch pattern.6. InterferencesThe type of tape used should be compatible with the type ofinks used.7. Apparatus7.1 Cutting ToolA multiblade cutter having a cuttingedge angle between 15 and 30 degrees that will make six cutsat once that are 2 mm apart. It is of particular importance thatthe cuttin
13、g edges be in good condition.NOTE 2Dull cutting edges require more pressure on the tool, whichincreases the difficulty in controlling the depth of the cuts. Dull edges canalso rupture or chip the substrate, ink, or coating and thus yieldinconsistent or inaccurate results.1This practice is under the
14、jurisdiction of ASTM Committee F01 on Electronicsand is the direct responsibility of Subcommittee F01.18 on Membrane Switches.Current edition approved Dec. 10, 2002. Published February 2002. Originallyapproved in 1997. Last previous edition approved in 1997 as F 184297.2Annual Book of ASTM Standards
15、, Vol 06.01.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7.2 TapeOne inch (25 mm) wide clear or semitranspar-ent pressure sensitive tape with an adhesion strength agreedupon by the supplier and the user is needed. Because of theva
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF18422002STANDARDTESTMETHODFORDETERMININGINKORCOATINGADHESIONONPLASTICSUBSTRATESFORMEMBRANESWITCHAPPLICATIONS

链接地址:http://www.mydoc123.com/p-535820.html