《ASTM D2152-2017 Standard Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone Immersion《用丙酮浸渍法测定挤出聚氯乙烯(PVC)管和模制配件熔合充分性的标准试验.pdf》由会员分享,可在线阅读,更多相关《ASTM D2152-2017 Standard Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone Immersion《用丙酮浸渍法测定挤出聚氯乙烯(PVC)管和模制配件熔合充分性的标准试验.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2152 13D2152 17 An American National StandardStandard Test Method forAdequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC)Pipe and Molded Fittings by Acetone Immersion1This standard is issued under the fixed designation D2152; the number immediately following the designation indica
2、tes the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination o
3、f the adequacy of fusion of extruded rigid poly(vinyl chloride) (PVC) pipe andmolded fittings as indicated by reaction to immersion in anhydrous acetone.1.2 The values stated in inch-pound units are to be regarded as the standard except where instruments are calibrated in SI units.1.3 This standard
4、does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use.Specif
5、ic hazards statements are given in Annex A1.1.4 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World
6、 Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for Testing3. Significance and Use3.1 This test method is applicable only for distinguishing between inadequately fused and adequately fused PVC. The dif
7、ferencebetween thermally degraded and adequately fused PVC cannot be detected by this test method. Acetone immersion is not asubstitute for burst, impact, or other physical or chemical tests on PVC pipe or fittings and it, therefore, shall not be used as theonly test specification for purchasing of
8、PVC pipe and fittings. This test only detects inadequate fusion and does not determine theover-all quality of the PVC pipe or fittings.3.2 This test method is useful in determining whether inadequate fusion contributed to failure of PVC pipe or fittings in otherphysical or chemical tests, or in serv
9、ice.3.3 This test method is useful in evaluating the adequacy of PVC fusion obtained in process or materials trials.3.4 This test method determines adequacy of fusion on a single, relatively small specimen. This test method requires the useof a hazardous reagent which must be properly handled and di
10、sposed. Therefore, this test method may not be cost-effective toemploy as a routine quality control test.4. Apparatus4.1 ContainerEither individual, sealable containers for each specimen or one large, airtight container capable of holdingseveral specimens without touching one another.4.2 Hydrometer
11、and CylinderPrecision hydrometer, graduated in thousandths, with a minimum range of 0.780 to 0.790 g/mLand a cylinder large enough to immerse the hydrometer.4.3 ThermometerASTM 12C total immersion thermometer, range from 20C to 102C accurate to 0.2C, or equivalent.1 This test method is under the jur
12、isdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.25 on Vinyl BasedPipe.Current edition approved May 1, 2013Nov. 1, 2017. Published June 2013January 2018. Originally approved in 1963T. Last previous edition approved in 20102013 asD2152 95D
13、2152 13.(2010). DOI: 10.1520/D2152-13.10.1520/D2152-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This d
14、ocument is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions
15、as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. Uni
16、ted States15. Reagent5.1 AcetoneAmerican Chemical Society Reagent Grade, having a maximum density of 0.7857 g/mL at 25C.NOTE 1See Annex A1 for the safety and health precautions to be used with acetone.5.2 Prior to conducting the test, check the density of the acetone with a precision hydrometer to d
17、etermine its dryness. If thedensity of the acetone is greater than 0.78900.934 g/mL at 23C, (corresponding to approximately 1 %2 % water by mass (see Fig.X1.1), use fresh acetone or dry the wet acetone with a drying agent. Recheck the density of the fresh or dried acetone before using.NOTE 2Wet acet
18、one can be dried by thoroughly agitating it with at least 15 g of anhydrous calcium sulfate (CaSO4) for each gram of water present.NOTE 3The presence of water in the acetone reduces its sensitivity to differences in the degree of fusion of rigid poly(vinyl chloride) (PVC). It isimportant to dry the
19、acetone properly and conduct the test in a sealed container, because acetone rapidly absorbs moisture from the atmosphere.NOTE 4Round-robin testing between four laboratories showed that test results are not significantly altered with up to 2 % water by weight in theacetone.6. Sampling6.1 Specimens s
20、hall be taken from individual pipe sections, fittings, or remnant portions of pipe or fittings. Specimens shall betaken from locations which are to be evaluated for adequacy of fusion, or immediately adjacent to them.6.2 The number of individual specimens to be tested and their locations shall be ch
21、osen to be representative of the pipe orfittings being evaluated for adequacy of fusion.7. Test Specimens7.1 Size of SpecimenSpecimen shall be a size that is convenient to immerse in the test container but not less than 12 in. (13mm) in height. For small diameter pipe, the specimen shall be a comple
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD21522017STANDARDTESTMETHODFORADEQUACYOFFUSIONOFEXTRUDEDPOLYVINYLCHLORIDEPVCPIPEANDMOLDEDFITTINGSBYACETONEIMMERSION

链接地址:http://www.mydoc123.com/p-511092.html