ASTM D4780-2012 Standard Test Method for Determination of Low Surface Area of Catalysts and Catalyst Carriers by Multipoint Krypton Adsorption《用多点氪吸附法测定催化剂及催化剂载体的低表面面积的标准试验方法》.pdf
《ASTM D4780-2012 Standard Test Method for Determination of Low Surface Area of Catalysts and Catalyst Carriers by Multipoint Krypton Adsorption《用多点氪吸附法测定催化剂及催化剂载体的低表面面积的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4780-2012 Standard Test Method for Determination of Low Surface Area of Catalysts and Catalyst Carriers by Multipoint Krypton Adsorption《用多点氪吸附法测定催化剂及催化剂载体的低表面面积的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4780 12Standard Test Method forDetermination of Low Surface Area of Catalysts andCatalyst Carriers by Multipoint Krypton Adsorption1This standard is issued under the fixed designation D4780; the number immediately following the designation indicates the year oforiginal adoption or, in
2、the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the specificsurface area of catalysts a
3、nd catalyst carriers in the range from0.05 to 10 m2/g. A volumetric measuring system is used toobtain at least three data points which fall within the linear BETregion.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This
4、 standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents
5、2.1 ASTM Standards:2D3663 Test Method for Surface Area of Catalysts andCatalyst CarriersD3766 Terminology Relating to Catalysts and CatalysisE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE456 Terminology Relating to Quality and StatisticsE691 Practice for Conducting an Int
6、erlaboratory Study toDetermine the Precision of a Test Method3. Terminology3.1 DefinitionsConsult Terminology D3766.3.2 Symbols:PH1= initial helium pressure, torr.PH2= helium pressure after equilibration, torr.TH1= temperature of manifold at initial heliumpressure, C.TH2= temperature of manifold aft
7、er equilibration,C.P1= initial Kr pressure, torr.T81= manifold temperature at initial Kr pressure,K.T1= manifold temperature at initial Kr pressure,C.P2= Kr pressure after equilibration, torr.T82= manifold temperature at P2,K.T2= manifold temperature at P2, C.Po,N= liquid nitrogen vapor pressure, to
8、rr.Po,krypton= calculated krypton vapor pressure, torr.T8s= liquid nitrogen temperature, K.X = relative pressure, P2/Po,krypton.Vd= volume of manifold, cm3.Vs= the apparent dead-space volume, cm3.Ws= weight of sample, g.W1= tare weight of sample tube, g.W2= weight of sample plus tare weight of tube,
9、 g.Vds= volume of krypton in the dead space, cm.3V1= See 11.3.5.V2= See 11.3.6.Vt= See 11.3.7.Va= See 11.3.9.Vm= See 11.6.4. Summary of Test Method4.1 A catalyst or catalyst carrier sample is degassed byheating in vacuum to remove absorbed vapors from thesurface. The quantity of krypton adsorbed at
10、various lowpressure levels is determined by measuring pressure differen-tials after introduction of a fixed volume of krypton to thesample at liquid nitrogen temperature.The specific surface areais then calculated from the sample weight and adsorption datausing the BET equation.5. Significance and U
11、se5.1 This test method has been found useful for the determi-nation of the specific surface area of catalysts and catalystcarriers in the range from 0.05 to 10 m2/g for materials1This test method is under the jurisdiction of ASTM Committee D32 onCatalysts and is the direct responsibility of Subcommi
12、ttee D32.01 on Physical-Chemical Properties.Current edition approved May 1, 2012. Published July 2012. Originally approvedin 1988. Last previous edition approved in 2007 as D478095(2007). DOI:10.1520/D4780-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Custom
13、er Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.specification, manufacturing control,
14、 and research and devel-opment in the evaluation of catalysts. The determination ofsurface area of catalysts and catalyst carriers above 10 m2/g isaddressed in Test Method D3663.6. Apparatus6.1 Aschematic diagram of the apparatus is shown in Fig. 1.It may be constructed of glass or of metal and may
15、operatemanually or automatically. It has the following features:6.1.1 Vacuum System, capable of attaining pressures below10-4torr (1 torr = 133.3 Pa). This will include a vacuum gage(not shown in Fig. 1). Access to the distribution manifold isthrough the valve V.6.1.2 Distribution Manifold, having a
16、 volume between 5and 40 cm3(Vd) known to the nearest 0.01 cm3. This volume isdefined as the volume between the stopcocks or valves and itincludes the volume within the pressure gage.6.1.3 Constant Volume Gages, capable of measuring 1 to 10torr to the nearest 0.001 torr and 0 to 1000 torr to the near
17、esttorr (1 torr = 133.3 Pa).6.1.4 Valve (H), from the helium supply to the distributionmanifold.6.1.5 Valve (K), from the krypton supply to the distributionmanifold.6.1.6 Sample Tube(s), with volume between 5 cm3and 25cm3, depending on the application. The sample tube(s) may beconnected to the distr
18、ibution manifold with standard taperjoints, glass-to-glass seals, or compression fittings.NOTE 1Modern commercial instruments may employ simple tubeswith volumes outside of this range, and may be capable of testing multiplesamples simultaneously rather than separately as stated in 9.1.6.1.7 Dewar Fl
19、ask(s) for immersion of the sample tube(s)in liquid nitrogen. The nitrogen level should be fixed at aconstant height by means of an automatic level controller ormanually refilled to a predetermined mark on the sampletube(s) about 30 to 50 mm below the distribution manifoldconnectors.6.1.8 Thermomete
20、r for measuring the temperature of thedistribution manifold (T1(i)orT2(i) in degrees Celsius. (Al-ternatively, the distribution manifold may be thermostatted afew degrees above ambient to obviate the necessity of record-ing this temperature.)6.1.9 Heating Mantle(s) or Small Furnace(s) for eachsample
21、 tube to allow outgassing samples at elevated tempera-tures.6.1.10 Laboratory Balance with 0.1 mg (107kg) sensitiv-ity.6.1.11 Thermometer for measuring the temperature of theliquid nitrogen bath (T8s(i) in kelvins. This will preferably bea nitrogen vapor-pressure-thermometer that gives Po,Ndirectlya
22、nd has greater precision, or a resistance thermometer fromwhich Po,Nvalues may be derived.7. Reagents7.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytica
23、l Reagents of the American Chemical Society,where such specifications are available.3Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.7.2 Helium Gas, at least 99.9 % pure.7.3
24、Krypton Gas, at least 99.9 % pure.7.4 Liquid Nitrogen, of such purity that the saturation vaporpressure Po,Nis not more than 20 torr above barometricpressure. A fresh daily supply is recommended.8. ProcedureSample Preparation and Degassing8.1 Select a sample tube of the desired size. A 5 cm3tube isp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD47802012STANDARDTESTMETHODFORDETERMINATIONOFLOWSURFACEAREAOFCATALYSTSANDCATALYSTCARRIERSBYMULTIPOINTKRYPTONADSORPTION

链接地址:http://www.mydoc123.com/p-517957.html