NAVY MIL-I-60284 B-1992 INITIATOR CARTRIDGE ACTUATED DELAY M32A1 ASSEMBLY《 M32A1火药驱动起始延迟装置》.pdf
《NAVY MIL-I-60284 B-1992 INITIATOR CARTRIDGE ACTUATED DELAY M32A1 ASSEMBLY《 M32A1火药驱动起始延迟装置》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-I-60284 B-1992 INITIATOR CARTRIDGE ACTUATED DELAY M32A1 ASSEMBLY《 M32A1火药驱动起始延迟装置》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-I-60284B 23 9999906 05093384-Ei I INCH-POUND I MIL-1-602 84B 17 March 1992 SUPERSEDING 30 October 1968 MIL-1-60284A(MU) MILITARY SPECIFICATION INITIATOR, CARTRIDGE ACTUATED, DELAY, M32A1 ASSEMBLY mis speccation is approved for use by all Depamnts and Agencies of the DeparMent of Defense. 1. SCOP
2、E 1.1 Scope. This specification covers the requirements for the M32A1 Delay Cartridge Actuated Initiator Assembly (see 6.1). 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications and standards. The following specifications and standards form a part of this document to the extent spe
3、cified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DODISS) and supplements thereto, cited in the solicitation (see 6.2). SPECIFICATIONS MILITARY MIL-A-2550 Amunition, General Speci
4、fication For MIL-1-14803 Initiator, Cartridge Actuated, Delay, M30A1, M32A1, M92, M43A1, and M120 Remanufactured Metal Parts Assembly MIL-1-605 15 Initiator, Cartridge Actuated, M30A1, M32A1, M43A1, M92, and M120 Metal Parts Assembly Beneficial comments (recommendations, additions, deletions) and an
5、y pertinent dafa which may be of use in improving this document should be dressed to: Commander, Indian Head Division, Naval Surface Warfare Center, Standardization Branch (Code 3730), 101 Strauss Avenue, Indian Head, MD 20640-5035, by using the Standardization Document improvement Proposal (DD Form
6、 1426) appearing at the end of this document or by sending a letter. AMSC NIA FSC 1377 DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-I-bO24B 33 = 9999906 0509339
7、b m MIL-I40284B STANDARDS MILITARY MIL-STD-105 Sampling Procedures And Tables For Inspection By Attributes MIL-STD-109 Quality Assurance Terms And Definitions MIL-STD453 Inspection, Radiographic MIL-STD-1168 Ammunition Lot Numbering MS28741 Hose Assembly, Detachable End Fitting, Medium Pressure (Unl
8、ess otherwise indicated, copies of federal and military specifications and standards are available from Standardization Documents Order Desk, Bldg. 4D, 700 Robbins Avenue, Philadelphia, PA 191 11-5094.) 2.1.2 Other Government documents, drawings, and publications. The following Government drawings f
9、orm a part of this specification to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation (see 6.2). DRAWINGS Naval Surface Warfare Center, Indian Head (CAGE Codes 19200 and 19203) 85933 12 Cartridge, Delay, M93 Assembly DL8595409 Initiator, Cartridg
10、e Actuated, Delay, M32A1 Assembly 8798142 Box, Packing, Ammunition, For Initiator, Cartridge Actuated, Delay, M10, M30A1, M31, M32A1, M42, M43A1, M72, M92, or M114 8798143 Box, Fiberboard (Inner), Packing, Ammunition, For Initiator, Cartridge Actuated, Delay, M10, M30A1, M31, M32A1, M42, M43A1, M72,
11、 M92, or M114 92 16933 Box, Fiberboard (Outer), Alternative, Packing Ammunition, for Initiator, Cartridge Actuated, Delay, M10, M30A1, M31, M32A1, M42, M43A1, M72, M92, or M114 (Application for copies should be addressed to: Commander, Indian Head Division, Naval Surface Warfare Center, Attn: Data C
12、ontrol Branch (Code 3720), Indian Head, MD 20640-5035.) 2.2 Order of precedence. In the event of a conflict between the text of this-document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unl
13、ess a specific exemption has been obtained. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-I-60284B 33 9999906 0509340 2 MIL-1-602 84B 3. REQUIREMENTS 3.1 Materiais. Ail materials used in the manufacture of the initiators shall conform to the
14、specifications referred to on the respective drawings unless specific approval in writing covering a departure therefrom has been obtained from the cognizant Navy design activity prior to manufacture. When alternate materials or methods of manufacture are specified on the drawings, the bidders selec
15、tions shall be clearly stated in the proposal. 3.2 Components. 3.2.1 Primary components. For the purpose of this specification, the M93 delay cartridge (Drawing 85933 12) is defined as a primary component. Only primary components from a single lot shall be used in a production lot of initiators; how
16、ever, one primary component production lot may be used in more than one initiator production lot. 3.2.2 Component parts. All component parts shall meet the applicable requirements of MIL-I- 14083 or MIL-1-60515 prior to assembly. 3.3 Breakaway torque. The chamber and cap of each assembled initiator
17、shall withstand a breakaway torque application of 400 inch-pounds without loosening or deformation (see 4.3.1). 3.4 Residual magnetism. The initiator shall not deflect the indicator of the compass more than five I) degrees in either direction (see 4.3.2). 3.5 Firing pin release. The firing pin of th
18、e assembled initiator, less safety pin, cartridge, cartridge retainer, and chamber shall release from the cocked position when the application of an axial load of 20 to 35 pounds has withdrawn the initiator pin 314 inch, maximum (see 4.2.3.3). 3.6 Initiator pin security. The initiator pin of the ass
19、embled initiator, less cartridge, cartridge retainer, and chamber shall not withdraw beyond the safety pin when subjected to an axial load of 200 to 220 pounds. Application of the load shall cause no deformation of the safety pin (see 4.2.3.4). 3.7 Radiographic examination. Each initiator assembly s
20、hall be radiographically examined for defects (see 4.3.5). 3.8 Functional. 3.8.1 Ballistics. Initiators loaded with cartridges from one accepted lot and temperature conditioned shall perform within the pressure values and delay times (see 6.4.1) specified in table I. Pressure values shall be recorde
21、d at the end of 15 feet of aircraft hose, assembly number MS28741-4, and a pressure chamber with a volume of 1 cubic inch. 3.8.1.1 Initiation. The initiator shall be fired by a source delivering an output pressure of 700 +25, -0 pounds per square inch gage (psig) at 70 f 5F. 3.8.2 Misfires. There sh
22、all be no misfires. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-I-60284B 33 9999906 0509343 4 m MIL-Id0284B 3.8.3 Mechanical failures. The initiator shall function without mechanical failure (see 6.4.2). TABLE I. Pressure values. Temperatur
23、e (Op) Pressure Sig) Ignition delay time, seconds Minimum Maximum -6Ot0 -70 500 1250 1.00 + 0.30, -0,20 65 to 75 600 1500 1.00 + 0.30, -0.20 195 to 205 800 1800 1.00 + 0.30, -0.20 3.9 Workmanship. Initiators shall be free of cracks, splits, or other defects which might prevent proper mating with con
24、necting parts or proper functioning of the device. 3.9.1 Metal defects. All components shall be free from cracks, splits, cold shuts, inclusions, porosity, or any similar defect. 3.9.2 Burr. No part shall have a burr which might interfere with the assembly or function of the item or which might be i
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILI60284B1992INITIATORCARTRIDGEACTUATEDDELAYM32A1ASSEMBLYM32A1 火药 驱动 起始 延迟 装置 PDF

链接地址:http://www.mydoc123.com/p-979921.html