ASTM F2753-2010 Standard Practice to Evaluate the Effect of Dynamic Rolling Load over Resilient Floor Covering System《评估动态滚动负荷对弹性地板覆盖系统的影响的标准实施规程》.pdf
《ASTM F2753-2010 Standard Practice to Evaluate the Effect of Dynamic Rolling Load over Resilient Floor Covering System《评估动态滚动负荷对弹性地板覆盖系统的影响的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2753-2010 Standard Practice to Evaluate the Effect of Dynamic Rolling Load over Resilient Floor Covering System《评估动态滚动负荷对弹性地板覆盖系统的影响的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2753 10Standard Practice toEvaluate the Effect of Dynamic Rolling Load over ResilientFloor Covering System1This standard is issued under the fixed designation F2753; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the determination of the effect ofdynamic rolling load over a resilient floor covering.1
3、.2 This practice is intended to be used by resilient, adhe-sive and underlayment manufacturers to measure the impact ofa dynamic rolling load over a specific product or a combinationof products.1.3 This practice may be used to evaluate the performanceof joints (sealed or welded) in the resilient flo
4、or covering.1.4 This practice may be used to aid in the diagnosis of aspecific assembly performance and provide comparative evalu-ation.1.5 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided f
5、or information onlyand are not considered standard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of
6、regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F141 Terminology Relating to Resilient Floor CoveringsF1482 Practice for Installation and Preparation of PanelType Underlayments to Receive Resilient Flooring3. Terminology3.1 Definitions used in this practice shall be in
7、 accordancewith Terminology F141.4. Significance and Use4.1 The effect of dynamic rolling load over resilient floorcovering system is important since the resistance reflects theability of a resilient floor covering system to properly performunder specific use or condition.4.2 Excessive rolling load
8、over an installed resilient floorcovering may cause floor covering system failures such asbond failure, delamination, and finish or coating deteriorations.4.3 The effect of dynamic rolling load shall be measured byqualitative evaluation comparing the tested assembly with astandard assembly.5. Appara
9、tus5.1 Rolling load simulator comparable or similar to theapparatus as described in Annex A1.6. Procedure6.1 Test Assembly:6.1.1 The test assembly shall have a minimum size of 12 in.(30.5 cm) by 24 in. (61.0 cm).6.1.2 The base substrate shall be rigid such as a concreteslab 4 in. (10 cm), a cementit
10、ious board or a34 in. (1.9 cm)plywood, panel type underlayments, (Practice F1482 providesadditional information), or others. Adhere the flooring testspecimen to the base substrate according to the manufacturersinstallation instructions.6.2 Testing:6.2.1 The test shall run at a temperature of 73 6 5F
11、 (2363C) and at 50 6 10 % relative humidity unless otherwisespecified.6.2.2 Install the wheel to be tested.6.2.3 After proper conditioning, the test assembly should beinstalled and fixed with clamps on the table. The assemblymust not move.6.2.4 Select the wheel path and the number of cycles.Usually
12、a series of 500 cycles is used.6.2.5 Place the required amount of auxiliary weights. Astarting weight of 100 lb (45.4 kg) is generally used to beginthe test.6.2.6 Turn ON the rolling load simulator.1This practice is under the jurisdiction of ASTM Committee F06 on ResilientFloor Coverings and is the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF27532010STANDARDPRACTICETOEVALUATETHEEFFECTOFDYNAMICROLLINGLOADOVERRESILIENTFLOORCOVERINGSYSTEM

链接地址:http://www.mydoc123.com/p-539393.html