ASTM F1473-2016 Standard Test Method for Notch Tensile Test to Measure the Resistance to Slow Crack Growth of Polyethylene Pipes and Resins《测量聚乙烯管和树脂抗裂缝缓慢扩展的切口拉伸试验用标准试验方法》.pdf
《ASTM F1473-2016 Standard Test Method for Notch Tensile Test to Measure the Resistance to Slow Crack Growth of Polyethylene Pipes and Resins《测量聚乙烯管和树脂抗裂缝缓慢扩展的切口拉伸试验用标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1473-2016 Standard Test Method for Notch Tensile Test to Measure the Resistance to Slow Crack Growth of Polyethylene Pipes and Resins《测量聚乙烯管和树脂抗裂缝缓慢扩展的切口拉伸试验用标准试验方法》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1473 13F1473 16Standard Test Method forNotch Tensile Test to Measure the Resistance to Slow CrackGrowth of Polyethylene Pipes and Resins1This standard is issued under the fixed designation F1473; the number immediately following the designation indicates the year oforiginal adoption or
2、, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method determines the resistance of polyethylene materials to slow c
3、rack growth under conditions specified within.NOTE 1This test method is known as PENT (Pennsylvania Notch Test) test.1.2 The test is generally performed at 80C and at 2.4 MPa, but may also be done at temperatures below 80C and with otherstresses low enough to preclude ductile failure and thereby eve
4、ntually induce brittle type of failure. Generally, polyethylenes willultimately fail in a brittle manner by slow crack growth at 80C if the stress is below 2.4 MPa.1.3 The test method is for specimens cut from compression molded plaques.2 See Appendix X1 for information relating tospecimens from pip
5、e.1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish
6、 appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D1600 Terminology for Abbreviated Terms Relating to PlasticsD4703 Practice for Compression Molding Thermoplastic Materials into Test Specimens, Pl
7、aques, or SheetsF412 Terminology Relating to Plastic Piping Systems3. Terminology3.1 Definitions are in accordance with Terminology F412. Abbreviations are in accordance with Terminology D1600, unlessotherwise indicated.3.2 Definitions:3.1.1 Definitions are in accordance with Terminology F412. Abbre
8、viations are in accordance with Terminology D1600, unlessotherwise indicated.3.2.1 brittle failurea pipe failure mode which exhibits no visible (to the naked eye) permanent material deformation(stretching, elongation, or necking down) in the area of the break (Terminology F412).3.3 Definitions of Te
9、rms Specific to This Standard:3.3.1 slow crack growththe slow extension of the crack with time.4. Summary of Test Method4.1 Specimens are prepared from compression molded plaques, precisely notched and then exposed to a constant tensile stressat elevated temperatures in air. Time on test is recorded
10、 for tests conducted against a minimum time before failure requirement orthe time to complete failure is recorded.1 This test method is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.40 on Test Methods.Current edition appro
11、ved Aug. 1, 2013Aug. 15, 2016. Published August 2013August 2016. Originally approved in 1997. Last previous edition approved in 20112013 asF1473 11.F1473 13. DOI: 10.1520/F1473-13.10.1520/F1473-16.2 Lu, X., and Brown, N., “A Test for Slow Crack Growth Failure in Polyethylene Under a Constant Load,”
12、Journal of Polymer Testing, Vol 11, pp. 309319, 1992.3 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This doc
13、ument is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as
14、 appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. Unite
15、d States1NOTE 2Minimum time before failure requirements are found in material or product specifications, codes, etc.5. Significance and Use5.1 This test method is useful to measure the slow crack growth resistance of molded plaques of polyethylene materials ataccelerated conditions such as 80C, 2.4-
16、MPa stress, and with a sharp notch.5.2 The testing time or time to failure depends on the following test parameters: temperature; stress; notch depth; and specimengeometry. Increasing temperature, stress, and notch depth decrease the time to failure. Thus, in reporting the test time or time tofailur
17、e, all the conditions of the test shall be specified.6. Apparatus6.1 Lever Loading Machine, with a lever arm ratio of about 5:1.The tensile load may also be applied directly using dead weightsor any other method for producing a constant load. The pull rods on the grips shall have universal action to
18、 prevent bending. Thegrips shall be serrated to prevent slippage. The load on the specimen shall be accurate to at least 60.5 %.6.2 Furnace, heated by ordinary incandescent light bulbs covered with aluminum foil or any other suitable heating element.6.3 Temperature Controller, shall be able to contr
19、ol the temperature within 60.5C with respect to the set point.6.4 Temperature-Measuring Device, a thermometer or a thermocouple which can measure the temperature with an accuracybetter than 0.5C.6.5 Timer, shall have an accuracy of at least 1 % and shall automatically stop when the specimen fails.6.
20、6 Alignment Jig, as shown in Fig. 1, which aligns the grips and the specimen when the specimen is being tightened in the grips.Alignment jigs which produce the same function may be used.6.7 Notching Machine , for notching the specimen is shown in Fig. 2 or other machines which produce the same resul
21、ts maybe used. The notching machine presses a razor blade into the specimen at a speed less than 0.25 mm/min. The depth of the notchis controlled within60.01 mm. The machine is designed so that the main notch and the side notches will be coplanar and the planeof the notching is perpendicular to the
22、tensile axis of the specimen. The thickness of the razor blade is approximately 0.2 mm.7. Precautions7.1 The load shall be carefully added to avoid shocking the specimen. When the specimen is inserted in the grips, bending andtwisting shall be avoided in order to prevent the premature activation of
23、the notch. Avoid exposure to fluids such as detergents.8. Test Specimens8.1 Specimens are machined from a compression molded plaque of the polyethylene material.8.2 Specimen GeometryA representative geometry for compression molded plaque specimens is shown in Fig. 3.8.3 Dimensional Requirements:8.3.
24、1 The side groove shall be 1.0 6 0.10 mm for all plaque thicknesses.FIG. 1 Alignment JigF1473 1628.3.2 The overall length is not critical except that the distance between the notch and the end of a grip should be more than 10mm. Thicker specimens should have a greater overall length so that the grip
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF14732016STANDARDTESTMETHODFORNOTCHTENSILETESTTOMEASURETHERESISTANCETOSLOWCRACKGROWTHOFPOLYETHYLENEPIPESANDRESINS

链接地址:http://www.mydoc123.com/p-534961.html