ASTM E1130-2002e1 Standard Test Method for Objective Measurement of Speech Privacy in Open Offices Using Articulation Index《使用声音清晰度指数在敞开式办公室内对谈话保密性进行客观量度的标准试验方法》.pdf
《ASTM E1130-2002e1 Standard Test Method for Objective Measurement of Speech Privacy in Open Offices Using Articulation Index《使用声音清晰度指数在敞开式办公室内对谈话保密性进行客观量度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1130-2002e1 Standard Test Method for Objective Measurement of Speech Privacy in Open Offices Using Articulation Index《使用声音清晰度指数在敞开式办公室内对谈话保密性进行客观量度的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1130 02e1Standard Test Method forObjective Measurement of Speech Privacy in Open OfficesUsing Articulation Index1This standard is issued under the fixed designation E 1130; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revis
2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEFootnote 4 was added editorially in March 2002.INTRODUCTIONThis is one of a series of test methods for eva
3、luating the acoustical characteristics of open officeenvironments and the performance of acoustical components. Other proposed test methods in thisseries deal with the laboratory measurement of interzone attenuation of partial height space dividersand ceiling systems.1. Scope1.1 This test method des
4、cribes a means of measuring speechprivacy objectively between locations in open offices. This testmethod relies upon acoustical measurements, published infor-mation on speech levels, and standard methods for assessingspeech communication. This test method does not measure theperformance of individua
5、l open office components which affectspeech privacy; it measures the privacy which results from aparticular configuration of components (1, 2).21.2 This test method is intended to be a field test for themeasurement of speech privacy in actual open offices. How-ever, this test method could be used in
6、 an environmentarranged to simulate an open office.1.3 This test method could be adapted for use in other openplan spaces such as open plan schools. It could also be adaptedfor measuring the speech privacy between open plan andenclosed spaces or between fully enclosed spaces.1.4 This test method rel
7、ies upon the Articulation Indexwhich predicts the intelligibility of speech for a group oftalkers and listeners. While both the Articulation Index and thistest method can be expected to reliably predict average speechprivacy, neither predicts the specific degree of speech privacyafforded to particul
8、ar open office occupants.1.5 The values stated in SI units are to be regarded as thestandard. The inch-pound units in parentheses are for informa-tion only.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of
9、 this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:C 384 Test Method for Impedance and Absorption ofAcoustical Materials by the Impedance Tube Method3C 634 Terminology
10、Relating to Environmental Acoustics3E 1041 Guide for Measurement of Masking Sound in OpenOffices4E 1179 Specification for Sound Sources Used for TestingOpen Office Components and Systems32.2 ANSI Standards:5S1.4 Specification for Sound Level MetersS1.6 Preferred Frequencies and Band Numbers for Acou
11、s-tical MeasurementsS1.11 Specification for Octave, Half-Octave and One-ThirdOctave Band Filter Sets3. Terminology3.1 DefinitionsThe acoustical terminology used in thistest method is consistent with Terminology C 634. Of specialimportance are the terms average sound pressure level andarithmetic mean
12、 sound pressure level, both of which aredefined in Terminology C 634, and source point which isdefined in Specification E 1179.1This test method is under the jurisdiction of ASTM Committee E33 onEnvironmental Acoustics and is the direct responsibility of Subcommittee E33.02 onOpen Plan Spaces.Curren
13、t edition approved Jan. 10, 2002. Published February 2002. Originallypublished as E 1130 86. Last previous edition E 1130 90 (1994)e1.2The boldface numbers in parentheses refer to the list of references at the end ofthis test method.3Annual Book of ASTM Standards, Vol 04.06.4Discontinued. See 2001 A
14、nnual Book of ASTM Standards, Vol 04.06.5Available from American National Standards Institute, 11 W. 42nd St., 13thFloor, New York, NY 10036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4. Summary of Test Method4.1 Select two loca
15、tions in an open office environment,between which the speech privacy is to be measured. Designateone location as the talker or source location and the other as thelistener or measurement location. These locations should typifythe usual working positions of office occupants.4.2 All masking sound syst
16、ems and HVAC systems shall beoperating in their usual manner.4.3 At the listener location, measure the ambient soundpressure levels in each one-third octave-band from 200 to 5000Hz and the A-weighted sound level.4.4 Locate a qualified sound source at the talker locationand orient it toward the liste
17、ner location. Drive the source withpink or white noise at a level sufficient to increase the one-thirdoctave-band sound pressure levels at the measurement locationby at least 10 dB above the ambient over the entire frequencyrange of interest. The sound pressure levels produced by thesound source at
18、a 0.9-m (3-ft) reference position for a knownelectrical input will have been previously established (3).4.5 Measure the sound pressure levels in one-third octavebands at the listener location with the source on.4.6 Calculate the level reduction in each one-third octaveband, that is, the difference i
19、n sound pressure levels producedby the sound source at 0.9 m (3 ft) and at the listener location.4.7 Determine the speech spectra to be used. The normalvoice spectrum of male speech peaks from Table 1 must beused; optionally, additional spectra may be used.4.8 Calculate the one-third octave-band sou
20、nd pressurelevels for the speech spectrum at the listener location. This iscarried out by subtracting the measured level reductions fromthe speech spectrum.4.9 Calculate the signal-to-noise ratio in each one-thirdoctave band by subtracting the measured ambient and soundpressure levels from the calcu
21、lated speech levels at the listenerlocation.4.10 Calculate the Articulation Index in accordance withSection 11 using the one-third octave-band signal-to-noiseratios.4.11 Report the Articulation Index to two decimal places asthe measure of speech privacy.5. Significance and Use5.1 The speech privacy
22、between open offices is determinedby the degree to which intruding speech sounds from adjacentoffices exceed the ambient sound pressure levels at the listen-ers ear; a classic signal-to-noise ratio situation.5.2 The sound pressure levels at the listeners ear fromspeech in adjacent offices depend upo
23、n:5.2.1 The individual vocal effort and orientation of thetalker,5.2.2 The attenuation of speech signals due to distance orintervening barriers, and5.2.3 The reinforcement of speech signals due to reflectionsfrom office surfaces such as the ceiling, furniture panels, lightfixtures, walls, or windows
24、.5.3 The ambient sound pressure levels will usually becontrolled to mask intruding speech. This is accomplished bymeans of a masking sound system. However, in certainpositions and frequency ranges, heating, ventilating, or airconditioning equipment (HVAC) may contribute significantlyto ambient sound
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME11302002E1STANDARDTESTMETHODFOROBJECTIVEMEASUREMENTOFSPEECHPRIVACYINOPENOFFICESUSINGARTICULATIONINDEX

链接地址:http://www.mydoc123.com/p-527976.html