ASTM E136-2009a 9375 Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750&176 C.pdf
《ASTM E136-2009a 9375 Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750&176 C.pdf》由会员分享,可在线阅读,更多相关《ASTM E136-2009a 9375 Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750&176 C.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E136 09aAn American National StandardStandard Test Method forBehavior of Materials in a Vertical Tube Furnace at 750C1This standard is issued under the fixed designation E136; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revi
2、sion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This fire-test-resp
3、onse test method covers the determi-nation under specified laboratory conditions of combustioncharacteristics of building materials. It is not intended to applyto laminated or coated materials.1.2 This test method references notes and footnotes thatprovide explanatory information. These notes and fo
4、otnotes,excluding those in tables and figures, shall not be considered asrequirements of this test method.1.3 The values stated in SI units are to be regarded asstandard. The values given in parentheses are for informationonly.1.4 Limitations of the test method are discussed in 1.1 andAnnex A1.1.5 T
5、his standard is used to measure and describe theresponse of materials, products, or assemblies to heat andflame under controlled conditions, but does not by itselfincorporate all factors required for fire-hazard or fire-riskassessment of the materials, products, or assemblies underactual fire condit
6、ions.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.7 Fire t
7、esting is inherently hazardous. Adequate safe-guards for personnel and property shall be employed inconducting these tests.2. Referenced Documents2.1 ASTM Standards:2D1929 Test Method for Determining Ignition Temperatureof PlasticsD3174 Test Method for Ash in the Analysis Sample of Coaland Coke from
8、 CoalE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE176 Terminology of Fire Standards2.2 ISO Standard:3ISO 1182 Noncombustibility Test for Building MaterialsISO 13943 Fire Safety-Vocabulary2.3 Other Standard:BS 476 Combustibility Test of Materials33. Terminology3.1 Definiti
9、onsFor definitions of terms found in this testmethod, refer to Terminology E176 and ISO 13943. In case ofconflict, the definitions given in Terminology E176 shallprevail.4. Summary of Test Method4.1 This test method uses a furnace consisting of a ceramictube containing an electric heating coil to ex
10、pose buildingmaterials to a temperature of 750C (1382F) until failureoccurs or for at least 30 min.4.2 The furnace consists of two concentric vertical refrac-tory tubes.4.3 Thermocouples are used to assess the temperature in-creases resulting from combustion of the building material.4.4 Visual obser
11、vation is used to assess the occurrence offlaming.5. Significance and Use5.1 While actual building fire exposure conditions are notduplicated, this test method will assist in indicating thosematerials which do not act to aid combustion or add appre-ciable heat to an ambient fire.5.2 Materials passin
12、g the test are permitted limited flamingand other indications of combustion.6. Apparatus6.1 The test apparatus, as shown in Fig. 1, shall consistprimarily of the following:1This test method is under the jurisdiction of ASTM Committee E05 on FireStandards and is the direct responsibility of Subcommit
13、tee E05.23 on Combustibil-ity.Current edition approved Oct. 15, 2009. Published November 2009. Originallyapproved in 1958. Last previous edition approved in 2009 as E136 09. DOI:10.1520/E0136-09A.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at
14、 serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Bar
15、r Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.1.1 Refractory TubesTwo concentric, refractory tubes,76 and 102 mm (3 and 4 in.) in inside diameter and 210 to 250mm (812 to 10 in.) in length, with axes vertical, and with heatapplied by electric heating coils outside of
16、 the larger tube. Acontrolled flow of air is admitted tangentially near the top ofthe annular space between the tubes and passes to the bottomof the inner tube. The outer tube rests on a refractory bottomand the inner tube rests on three spacer blocks so as to afforda total opening under the inner t
17、ube equal to or greater than thatof the annular space. The refractory bottom plate has aremovable plug for cleaning.6.1.2 Transparent CoverA transparent cover of heat-resistant glass or other transparent material shall be providedover the top of the inner tubes. The cover shall have a circularopenin
18、g 28.7 6 0.8 mm (118 6132 in.) centered over the axisof the tubes. This opening has an area of 645 mm2(1.0 in.2).The cover shall be in two equally-sized, movable parts.6.1.3 Thermocouples and an automatically recording deviceshall be provided. The thermocouples shall be located asfollows:6.1.3.1 The
19、rmocouple T1is located in the center of the airspace between the two concentric, refractory tubes; approxi-mately 204 mm (8 in.) down from the top of the 102-mm(4-in.) diameter tube (Note 1).6.1.3.2 Thermocouple T3is located at the approximategeometric center of the specimen.6.1.3.3 Thermocouple T4i
20、s located on the surface, incontact with the test specimen; in the same horizontal plane asT3.6.1.3.4 Thermocouples T1, T3and T4shall have a timeconstant (time to reach 63.2 % of the furnace air temperature of750C (1382F) of 5 to 10 s (Note 2).NOTE 1Thermocouple T1is used for better regulation of th
21、e tempera-ture of the air in the furnace space.NOTE 2Ungrounded, metallic-sheathed thermocouples of 1-mm di-ameter have been found to meet the time constant requirements.6.2 Specimen HolderThe specimen holder for solid testspecimens shall be as shown in Fig. 2.6.2.1 Test specimens in granular or pow
22、der form shall becontained in thin-wall, open-top vessels of inert materialswhose outside dimensions conform to the test specimen shapeand maximum size specified in 7.1. These vessels shall havewalls of either solid or mesh construction.6.3 Test Specimen LocationDuring the test, the geometriccenter
23、of the test specimen shall be located at the geometriccenter 63mm(618 in.) of the 76-mm (3-in.) diameter tube.7. Test Specimens7.1 All test specimens shall be 38 by 38 by 51 6 2.5 mm(1.5 by 1.5 by 2.0 6 0.1 in.).7.2 The test specimens shall be dried at 60 6 3C(140 6 5F) for not less than 24 h but no
24、 more than 48 h.NOTEInch-Pound Equivalentsin. 3 4 6 10 1034 1in.2No. 16 Awgmm 76 102 152 254 273 6.4 cm21.29FIG. 1 Cross Section of Furnace AssemblyE136 09a27.3 Test specimens shall then be placed in a desiccator tocool at least 1 h before testing.7.4 Not less than four identical specimens shall be
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME1362009A9375STANDARDTESTMETHODFORBEHAVIOROFMATERIALSINAVERTICALTUBEFURNACEAT750176CPDF

链接地址:http://www.mydoc123.com/p-526953.html