ASTM D7565 D7565M-2010 5000 Standard Test Method for Determining Tensile Properties of Fiber Reinforced Polymer Matrix Composites Used for Strengthening of Civil Structures《测定土木建筑增.pdf
《ASTM D7565 D7565M-2010 5000 Standard Test Method for Determining Tensile Properties of Fiber Reinforced Polymer Matrix Composites Used for Strengthening of Civil Structures《测定土木建筑增.pdf》由会员分享,可在线阅读,更多相关《ASTM D7565 D7565M-2010 5000 Standard Test Method for Determining Tensile Properties of Fiber Reinforced Polymer Matrix Composites Used for Strengthening of Civil Structures《测定土木建筑增.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7565/D7565M 10Standard Test Method forDetermining Tensile Properties of Fiber Reinforced PolymerMatrix Composites Used for Strengthening of CivilStructures1This standard is issued under the fixed designation D7565/D7565M; the number immediately following the designation indicates theye
2、ar of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes the requirements for sampl
3、epreparation, tensile testing, and results calculation of flat fiberreinforced polymer (FRP) composite materials used for thestrengthening of structures made of materials such as metals,timber, masonry, and reinforced concrete. The method may beused to determine the tensile properties of wet lay-up
4、andpre-impregnated FRP composites fabricated on site or manu-factured in a factory setting. The FRP composite may be ofeither unidirectional (0-degrees) or cross-ply (0/90 type) rein-forcement. For cross-ply laminates, the construction may beachieved using multiple-layers of unidirectional fibers at
5、 either0 or 90 degrees, or one or more layers of stitched or woven0/90 fabrics. The composite material forms are limited tocontinuous fiber or discontinuous fiber-reinforced compositesin which the laminate is balanced and symmetric with respectto the test direction. The method only covers the determ
6、inationof the tensile properties of the FRP composite material. Othercomponents used to attach the FRP material to the substrate,such as the primer, putty, and adhesive in externally bondedstrengthening systems, are excluded from the sample prepara-tion and testing detailed in this document. This te
7、st methodrefers to Test Method D3039/D3039M for conduct of the tests.1.2 The values stated in either SI units or inch-pound unitsare to be regarded as standard. Within the text, the inch-poundunits are shown in brackets. The values stated in each systemare not exact equivalents; therefore, each syst
8、em must be usedindependently of the other. Combining values from the twosystems may result in nonconformance with the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish a
9、ppro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D883 Terminology Relating to PlasticsD3039/D3039M Test Method for Tensile Properties ofPolymer Matrix Composite MaterialsD3878 Terminology for Co
10、mposite MaterialsD5229/D5229M Test Method for Moisture AbsorptionProperties and Equilibrium Conditioning of Polymer Ma-trix Composite MaterialsD5687/D5687M Guide for Preparation of Flat CompositePanels with Processing Guidelines for Specimen Prepara-tionE6 Terminology Relating to Methods of Mechanic
11、al TestingE122 Practice for Calculating Sample Size to Estimate,With Specified Precision, the Average for a Characteristicof a Lot or ProcessE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE456 Terminology Relating to Quality and Statistics3. Terminology3.1 DefinitionsTermin
12、ology D3878 defines terms relatingto high-modulus fibers and their composites. TerminologyD883 defines terms relating to plastics.Terminology E6 definesterms relating to mechanical testing. Terminology E456 andE177 define terms relating to statistics. In the event of aconflict between terms, Termino
13、logy D3878 shall have prece-dence over the other standards.3.2 Definitions of Terms Specific to This Standard:3.2.1 screed, vto move a flat rule along the top of asaturated laminate to level the top of the laminate andsimultaneously remove excess resin.3.2.2 shop-manufactured FRP composite, nan FRP
14、com-posite material manufactured under controlled conditions usingan automated process in a factory, typically with tight controlover the volume fractions and alignment of fibers, matrix, and1This test method is under the jurisdiction of ASTM Committee D30 onComposite Materials and is the direct res
15、ponsibility of Subcommittee D30.05 onStructural Test Methods.Current edition approved April 1, 2010. Published May 2010. Originallyapproved in 2009. Last previous edition approved in 2009 as D7565/D7565M 09.DOI: 10.1520/D7565_D7565M-10.2For referenced ASTM standards, visit the ASTM website, www.astm
16、.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.voids in t
17、he material as well as the cross-sectional geometry.For strengthening applications, shop-manufactured FRP com-posites are typically bonded to the substrate subsequent to thefabrication of the composite reinforcement3.2.3 wet lay-up FRP composite, nan FRP compositematerial fabricated by manually impr
18、egnating dry fibers with amatrix of polymeric resin. Semi-automated processes such asmachine-aided wetting of fabrics before placement or vacuum-aided impregnation of laminates after placement are consideredpart of wet lay-up FRP. For civil infrastructure strengtheningapplications, the degree of con
19、trol over the volume fractions offibers, matrix, and voids as well as the overall cross-sectionalgeometry in wet lay-up FRP composites may be less than thatfor shop-manufactured composites on account of the manualprocess. For strengthening applications, wet lay-up FRP com-posites are typically appli
20、ed to the substrate at the same timethe dry fiber is impregnated. The impregnating resin acts as thesaturant for the FRP composite and as the bonding agentbetween the composite reinforcement and the substrate. Wetlay-up specimens may be fabricated in either a field or alaboratory setting.3.3 Symbols
21、:3.3.1 CVsample coefficient of variation.3.3.2 F*force carrying capacity of FRP laminate per unitwidth.3.3.3 K*stiffness of FRP laminate per unit width.3.3.4 Lgextensometer gage length.3.3.5 nnumber of specimens.3.3.6 Pforce carried by test coupon.3.3.7 Pmaxmaximum tensile force.3.3.8 sn1sample stan
22、dard deviation.3.3.9 wcoupon width.3.3.10 xItest result for an individual coupon from thesample population for a given property.3.3.11 xmean or average (estimate of mean) of a samplepopulation for a given property.3.3.12 snormal stress.4. Summary of Test Method4.1 Flat FRP specimens are prepared usi
23、ng a wet lay-upfabrication procedure or cut from a shop-manufactured lami-nate. For testing purposes, wet lay-up material may be preparedin a laboratory or field setting, as the testing objectives dictate.The testing of the specimens is carried out according to theprovisions of Test Method D3039/D30
24、39M. The ultimate forceper unit width of the material is determined from the maximumforce carried before failure. If the load-strain response of thematerial is monitored with strain gages or extensometers, thenthe stiffness of the material per unit width and the ultimatetensile strain of the materia
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7565D7565M20105000STANDARDTESTMETHODFORDETERMININGTENSILEPROPERTIESOFFIBERREINFORCEDPOLYMERMATRIXCOMPOSITESUSEDFORSTRENGTHENINGOFCIVILSTRUCTURES

链接地址:http://www.mydoc123.com/p-525812.html