ASTM D7151-2015 0732 Standard Test Method for Determination of Elements in Insulating Oils by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES)《采用感应耦合等离子体发射光谱法 (ICP.pdf
《ASTM D7151-2015 0732 Standard Test Method for Determination of Elements in Insulating Oils by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES)《采用感应耦合等离子体发射光谱法 (ICP.pdf》由会员分享,可在线阅读,更多相关《ASTM D7151-2015 0732 Standard Test Method for Determination of Elements in Insulating Oils by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES)《采用感应耦合等离子体发射光谱法 (ICP.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7151 15Standard Test Method forDetermination of Elements in Insulating Oils by InductivelyCoupled Plasma Atomic Emission Spectrometry (ICP-AES)1This standard is issued under the fixed designation D7151; the number immediately following the designation indicates the year oforiginal adop
2、tion or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes the determination of metalsand contaminants i
3、n insulating oils by inductively coupledplasma atomic emission spectrometry (ICP-AES). The specificelements are listed in Table 1. This test method is similar toTest Method D5185, but differs in methodology, which resultsin the greater sensitivity required for insulating oil applica-tions.1.2 This t
4、est method uses oil-soluble metals for calibrationand does not purport to quantitatively determine insolubleparticulates. Analytical results are particle size dependent, andlow results are obtained for particles larger than severalmicrometers.21.3 This test method determines the dissolved metals (wh
5、ichcan originate from overheating or arcing, or both) and a portionof the particulate metals (which generally originate from awear mechanism). While this ICP method detects nearly allparticles less than several micrometers, the response of largerparticles decreases with increasing particle size beca
6、use largerparticles are less likely to make it through the nebulizer andinto the sample excitation zone.1.4 This test method includes an option for filtering the oilsample for those users who wish to separately determinedissolved metals and particulate metals (and hence, totalmetals).1.5 Elements pr
7、esent at concentrations above the upper limitof the calibration curves can be determined with additional,appropriate dilutions and with no degradation of precision.1.6 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.7 This sta
8、ndard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and to determine theapplicability of regulatory limitations prior to use.2. Referenced Documents2.1
9、 ASTM Standards:3C1109 Practice for Analysis of Aqueous Leachates fromNuclear Waste Materials Using Inductively CoupledPlasma-Atomic Emission SpectroscopyD923 Practices for Sampling Electrical Insulating LiquidsD1744 Test Method for Water in Liquid Petroleum Productsby Karl Fischer Reagent4D2864 Ter
10、minology Relating to Electrical Insulating Liq-uids and GasesD4307 Practice for Preparation of Liquid Blends for Use asAnalytical StandardsD5185 Test Method for Multielement Determination ofUsed and Unused Lubricating Oils and Base Oils byInductively Coupled Plasma Atomic Emission Spectrom-etry (ICP
11、-AES)E177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Terminology3.1 Definitions for general terms are found in TerminologyD2864.3.2 Definitions of Terms Specific to This Standa
12、rd:3.2.1 Babington-type nebulizer, na device that generatesan aerosol by flowing a liquid over a surface that contains anorifice from which gas flows at a high velocity.3.2.2 inductively-coupled plasma (ICP), na high-temperature discharge generated by flowing an ionizable gasthrough a magnetic field
13、 induced by a load coil that surroundsthe tubes carrying the gas.1This test method is under the jurisdiction of ASTM Committee D27 onElectrical Insulating Liquids and Gases and is the direct responsibility of Subcom-mitteeD27.03 on Analytical Tests.Current edition approved May 1, 2015. Published Jun
14、e 2015. Originallyapproved in 2005. Last previous edition approved in 2013 as D7151-13. DOI:10.1520/D7151-15.2Eisentraut, K. J., Newman, R. W., Saba, C. S., Kauffman, R. E., and Rhine, W.E., Analytical Chemistry, Vol 56, 1984.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orco
15、ntact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.Copyright ASTM International, 100 Barr H
16、arbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.3 linear response range, nthe elemental concentrationrange over which the calibration curve is a straight line, withinthe precision of the test method.3.2.4 profiling, na technique that determines the wave-length for which
17、 the signal intensity measured for a particularanalyte is a maximum.3.2.5 wear metal, nan element introduced into the oil bywear of oil-wetted parts.3.2.6 dissolved metal, na metallic element in the oil whichwill pass a 0.45 m filter.4. Summary of Test Method4.1 A weighed portion of a thoroughly hom
18、ogenized insu-lating oil is diluted by weight with kerosine or other suitablesolvent. Standards are prepared in the same manner. Aninternal standard may be added to the solutions to compensatefor variations in test specimen introduction efficiency. Thesolutions may be introduced to the ICP instrumen
19、t by aperistaltic pump. If free aspiration is used, an internal standardshall be used. By comparing emission intensities of elements inthe test specimen with emission intensities measured with thestandards, the concentrations of elements in the test specimenare calculated.5. Significance and Use5.1
20、This test method covers the rapid determination of 12elements in insulating oils, and it provides rapid screening ofused oils for indications of wear. Test times approximateseveral minutes per test specimen, and detectability is in the 10through 100 g/kg range.5.2 This test method can be used to mon
21、itor equipmentcondition and help to define when corrective action is needed.It can also be used to detect contamination such as fromsilicone fluids (via Silicon) or from dirt (via Silicon andAluminum).5.3 This test method can be used to indicate the efficiency ofreclaiming used insulating oil.6. Int
22、erferences6.1 SpectralCheck all spectral interferences expectedfrom the elements listed in Table 1. Follow the ICP manufac-turers operating guide to develop and apply correction factorsto compensate for the interferences. To apply interferencecorrections, all concentrations must be within the previo
23、uslyestablished linear response range of each element listed inTable 1.6.1.1 Spectral interferences can usually be avoided byjudicious choice of analytical wavelengths. When spectralinterferences cannot be avoided, the necessary corrections shallbe made using the computer software supplied by the IC
24、Pmanufacturer or the empirical method given in Test MethodC1109 or by Boumans.56.1.2 Interference correction factors can be negative ifoff-peak background correction is employed for an element. Anegative correction factor can result when an interfering line isencountered at the background correction
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD715120150732STANDARDTESTMETHODFORDETERMINATIONOFELEMENTSININSULATINGOILSBYINDUCTIVELYCOUPLEDPLASMAATOMICEMISSIONSPECTROMETRYICPAES

链接地址:http://www.mydoc123.com/p-524631.html