ASTM D6855-2017 1875 Standard Test Method for Determination of Turbidity Below 5 NTU in Static Mode《用静态法测定5NTU下浊度的标准试验方法》.pdf
《ASTM D6855-2017 1875 Standard Test Method for Determination of Turbidity Below 5 NTU in Static Mode《用静态法测定5NTU下浊度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6855-2017 1875 Standard Test Method for Determination of Turbidity Below 5 NTU in Static Mode《用静态法测定5NTU下浊度的标准试验方法》.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6855 17Standard Test Method forDetermination of Turbidity Below 5 NTU in Static Mode1This standard is issued under the fixed designation D6855; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision
2、. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the static determination ofturbidity in water (see 4.1).1.2 This test method is applicable to the measurem
3、ent ofturbidities under 5.0 nephelometric turbidity units (NTU).1.3 This test method was tested on municipal drinkingwater, ultra-pure water, and low turbidity samples. It is theusers responsibility to ensure the validity of this test method forwaters of untested matrices.1.4 This test method uses c
4、alibration standards are definedin NTU values, but other assigned turbidity units are assumedto be equivalent.1.5 This test method assigns traceable reporting units to thetype of respective technology that was used to perform themeasurement. Units are numerically equivalent with respect tothe calibr
5、ation standard. For example, a 1.0 NTU formazinstandard is also equal to a 1.0 FNU standard, a 1.0 FNRUstandard, and so forth.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish ap
6、pro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.Refer to the MSDSs for all chemicals used in this test method.1.7 This international standard was developed in accor-dance with internationally recognized principles on stan
7、dard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D1129 Terminology Relating to WaterD1192 Guid
8、e for Equipment for Sampling Water and Steamin Closed Conduits (Withdrawn 2003)3D1193 Specification for Reagent WaterD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3370 Practices for Sampling Water from Closed ConduitsD5847 Practice for Wri
9、ting Quality Control Specificationsfor Standard Test Methods for Water AnalysisD7315 Test Method for Determination of Turbidity Above 1Turbidity Unit (TU) in Static ModeE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 Other Referenced Standards:U.S.
10、 EPA Method 180.1 Methods for Chemical Analysis ofWater and Wastes, Turbidity4ISO 7027 Water Qualityfor the Determination of Turbid-ity53. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this standard, refer toTerminology D1129.3.2 Definitions of Terms Specific to This Standard:3.2
11、.1 calibration turbidity standard, na turbidity standardthat is traceable and equivalent to the reference turbiditystandard to within statistical errors.3.2.1.1 DiscussionCalibration turbidity standards includecommercially prepared 4000 NTU formazin, stabilized for-mazin (see 9.2.3), and styrenedivi
12、nylbenzene (SDVB) (see1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.07 on Sediments,Geomorphology, and Open-Channel Flow.Current edition approved Nov. 1, 2017. Published November 2017. Originallyapproved in 2003. Last p
13、revious edition approved in 2012 as D6855 12. DOI:10.1520/D6855-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM we
14、bsite.3The last approved version of this historical standard is referenced onwww.astm.org.4Available from United States Environmental ProtectionAgency (EPA), WilliamJefferson Clinton Bldg., 1200 Pennsylvania Ave., NW, Washington, DC 20460,http:/www.epa.gov.5Available from International Organization
15、for Standardization (ISO), ISOCentral Secretariat, BIBC II, Chemin de Blandonnet 8, CP 401, 1214 Vernier,Geneva, Switzerland, http:/www.iso.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 194
16、28-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Techn
17、ical Barriers to Trade (TBT) Committee.19.2.4). These standards may be used to calibrate the instrument.Calibration standards may be instrument specific.3.2.2 calibration verification standards, ndefined stan-dards used to verify the accuracy of a calibration in themeasurement range of interest.3.2.
18、2.1 DiscussionThese standards may not be used toperform calibrations, only calibration verifications. Includedstandards are opto-mechanical light scatter devices, gel-likestandards, or any other type of stable liquid standard. Calibra-tion verification standards may be instrument specific.3.2.3 neph
19、elometric turbidity measurement, nthe mea-surement of light scatter from a sample in a direction that is at90 with respect to the centerline of the incident light path.3.2.3.1 DiscussionUnits are NTU (nephelometric turbid-ity units); when ISO 7027 technology is employed units are inFNU (formazin nep
20、helometric units).3.2.4 ratio turbidity measurement, nthe measurement de-rived through the use of a nephelometric detector that serves asthe primary detector and one or more other detectors used tocompensate for variation in incident light fluctuation, straylight, instrument noise, or sample color.3
21、.2.5 reference turbidity standard, na standard that issynthesized reproducibly from traceable raw materials by theuser.3.2.5.1 DiscussionAll other standards are traced back tothis standard. The reference standard for turbidity is formazin(see 9.2.2).3.2.6 seasoning, nthe process of conditioning labw
22、arewith the standard to be diluted to a lower value.3.2.6.1 DiscussionThe process reduces contamination anddilution errors. See Appendix X2 for the suggested procedure.3.2.7 stray light, nall light reaching the detector other thanthat contributed by the sample.3.2.7.1 DiscussionExamples: ambient lig
23、ht leakage, inter-nal reflections and divergent light in optical systems.3.2.8 turbidimeter, nan instrument that measures lightscatter caused by particulates within a sample and converts themeasurement to a turbidity value.3.2.8.1 DiscussionThe detected light is quantitativelyconverted to a numeric
24、value that is traced to a light-scatterstandard.3.2.9 turbidity, nan expression of the optical properties ofa sample that causes light rays to be scattered and absorbedrather than transmitted in straight lines through the sample.3.2.9.1 DiscussionTurbidity of water is caused by thepresence of suspen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD685520171875STANDARDTESTMETHODFORDETERMINATIONOFTURBIDITYBELOW5NTUINSTATICMODE 静态 测定 NTU 浊度 标准 试验

链接地址:http://www.mydoc123.com/p-523784.html