ASTM D5946-2017 red 6250 Standard Test Method for Corona-Treated Polymer Films Using Water Contact Angle Measurements《对电晕处理聚合物薄膜进行水接触角测量的标准试验方法》.pdf
《ASTM D5946-2017 red 6250 Standard Test Method for Corona-Treated Polymer Films Using Water Contact Angle Measurements《对电晕处理聚合物薄膜进行水接触角测量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5946-2017 red 6250 Standard Test Method for Corona-Treated Polymer Films Using Water Contact Angle Measurements《对电晕处理聚合物薄膜进行水接触角测量的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5946 09D5946 17Standard Test Method forCorona-Treated Polymer Films Using Water Contact AngleMeasurements1This standard is issued under the fixed designation D5946; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers measurement of the contact angle of water droplets on corona-treated polymer film sur
3、faces.NOTE 1This test method standard is identical to ISO 15989.1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It
4、 is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardizationestab
5、lished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD724 Test Me
6、thod for Surface Wettability of Paper (Angle-of-Contact Method) (Withdrawn 2009)3E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method2.2 ISO Standard:4ISO 15989 PlasticsFilm and SheetingMeasurement of Water-Contact Angle of Corona-Treated Films3. Terminol
7、ogy3.1 Definitions of Terms Specific to This Standard:3.1.1 static contact angle, (degrees), nthe angle between the substrate surface and the tangent line drawn to the dropletsurface at the three-phase point, when a liquid drop is resting on a plane solid surface.3.1.1.1 DiscussionContact angle valu
8、es can be determined as follows: (1) by analyzing an image of a droplet using various projection or reflectivedevices and measuring the contact angle directly with a protractor by using tangential alignment of a cursor line or the use ofreference alignment procedures (Test Method D724); or (2) by an
9、alyzing an image of a droplet using various projection orreflective devices and measuring the height and width on the substrate surface to calculate the contact angle as follows:52arctanH/R! (1)where: = contact angle,1 This test method is under the jurisdiction of ASTM Committee D20 on Plastics and
10、is the direct responsibility of Subcommittee D20.19 on Film, Sheeting, and MoldedProducts.Current edition approved April 1, 2009May 1, 2017. Published April 2009June 2017. Originally approved in 1996. Last previous edition approved in 20042009 asD5946 - 04.D5946 - 09. DOI: 10.1520/D5946-09.10.1520/D
11、5946-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standa
12、rd is referenced on www.astm.org.4 Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http:/www.ansi.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been
13、 made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.
14、*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1H = height of a droplets image, andR = half its width.3.1.1.2 DiscussionInstrumentation is also available that utilizes a
15、n image and directly determines the contact angle based on the calculation shownfor Method (2) of U.S. Patent No. 5,268,733.3.1.1.3 DiscussionMethod (1) may be biased due to the subjective nature of visually finding a tangent to the droplet image at the three-phase point;if Method (1) is to be used,
16、 the bias of each operators measurements shall be determined. Because Method (2) utilizes measureddimensions of the droplet, it would be expected to have less bias. Comparative analyses using these various procedures have notbeen conducted. Therefore, caution is recommended when comparing data obtai
17、ned from these different methods.3.1.1.4 DiscussionMethod (2) may not be applicable in special cases in which the contact angle is greater than 904. Summary of Test Method4.1 In this test method, drops of water are placed on the surface of a film sample, and the contact angle values are measuredand
18、then averaged.5. Significance and Use5.1 The ability of polymer films to retain inks, coatings, adhesives, etc. is primarily dependent on the character of their surfacesand can be improved by one of several surface-treating techniques. The electrical discharge treatment, such as corona treatment,has
19、 been found to increase the wetting tension of a polymer film. The stronger the treatment, the more actively the surface reactswith different polar interfaces. It is therefore possible to relate the contact angle of a polymer film surface to its ability to acceptand retain inks, coatings, adhesives,
20、 etc., if the ink, coating, or adhesive contains the polar functionalities. Contact angle in itselfis not a completely acceptable measure of ink, coating, or adhesive adhesion.5.2 The wetting tension of a polymer film belongs to a group of physical parameters for which no standard of accuracy exists
21、.The wetting tension of a polymer cannot be measured directly because solids do not change shape measurably in reaction to surfaceenergy. Many indirect methods have been proposed.5 Different test methods tend to produce different results on identical samples.Practical determination of a solids surfa
22、ce energy uses this interaction of the solid with test liquids.5.3 Although the level of surface treatment of polymer films has been traditionally defined in the industry in terms of dynes/cm(mN/m), these values are derived from a subjective interpretation of the observed test liquid behavior.5.4 Th
23、e following ranges of water contact angle values can be used as a guide for defining the level of surface treatment ofpolyolefins and many other polymer films with initial low surface energies:5 Wu, S., Polymer Interface and Adhesion, Marcel Dekker, Inc., New York, NY, 1982.D5946 172Marginal or no t
24、reatment 90Low treatment 85 to 90Medium treatment 78 to 84High treatment 71 to 77Very high treatment 715.4.1 The suitability of the test for specification acceptance, manufacturing control, and end use of polymer films will have tobe established through capability studies for each particular film an
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD59462017RED6250STANDARDTESTMETHODFORCORONATREATEDPOLYMERFILMSUSINGWATERCONTACTANGLEMEASUREMENTS

链接地址:http://www.mydoc123.com/p-521095.html