ASTM D5610-1994(2008) 752 Standard Guide for Defining Initial Conditions in Groundwater Flow Modeling《确定地下水流型初始条件的标准指南》.pdf
《ASTM D5610-1994(2008) 752 Standard Guide for Defining Initial Conditions in Groundwater Flow Modeling《确定地下水流型初始条件的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5610-1994(2008) 752 Standard Guide for Defining Initial Conditions in Groundwater Flow Modeling《确定地下水流型初始条件的标准指南》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5610 94 (Reapproved 2008)Standard Guide forDefining Initial Conditions in Ground-Water Flow Modeling1This standard is issued under the fixed designation D 5610; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers techniques and procedures used indefining initial conditions for modeling saturated ground-wate
3、rflow. The specification of initial conditions is an essential partof conceptualizing and modeling ground-water systems.1.2 This guide offers an organized collection of informationor a series of options and does not recommend a specificcourse of action. This document cannot replace education orexper
4、ience and should be used in conjunction with professionaljudgment. Not all aspects of this guide may be applicable in allcircumstances. This ASTM standard is not intended to repre-sent or replace the standard of care by which the adequacy ofa given professional service must be judged, nor should thi
5、sdocument be applied without consideration of a projects manyunique aspects. The word “Standard” in the title of thisdocument means only that the document has been approvedthrough the ASTM consensus process.2. Referenced Documents2.1 ASTM Standards:2D 653 Terminology Relating to Soil, Rock, and Cont
6、ainedFluidsD 5447 Guide for Application of a Ground-Water FlowModel to a Site-Specific ProblemD 5609 Guide for Defining Boundary Conditions inGround-Water Flow Modeling3. Terminology3.1 Definitions:3.1.1 aquifer, confinedan aquifer bounded above andbelow by confining beds and in which the static hea
7、d is abovethe top of the aquifer.3.1.2 conceptual modelan interpretation or working de-scription of the characteristics of the physical system.3.1.3 fluxthe volume of fluid crossing a unit cross-sectional surface area per unit time.3.1.4 ground-water flow modelan application of a math-ematical model
8、 to represent a ground-water flow system.3.1.5 hydraulic conductivity(field aquifer tests), the vol-ume of water at the existing kinematic viscosity that will movein a unit time under unit hydraulic gradient through a unit areameasured at right angles to the direction of flow.3.1.6 hydrologic condit
9、iona set of ground-water inflowsor outflows, boundary conditions, and hydraulic properties thatcauses potentiometric heads to adopt a distinct pattern.3.1.7 simulationone complete execution of the computerprogram, including input and output.3.1.8 transmissivitythe volume of water at the existingkine
10、matic viscosity that will move in a unit time under a unithydraulic gradient through a unit width of the aquifer.3.1.9 unconfined aquiferan aquifer that has a water table.3.1.10 For definitions of other terms used in this testmethod, see Terminology D 653.4. Significance and Use4.1 Accurate definiti
11、on of initial hydrologic conditions is anessential part of conceptualizing and modeling transientground-water flow, because results of a simulation may beheavily dependent upon the initial conditions.5. Initial Conditions5.1 Initial hydrologic conditions for a flow system arerepresented by the head
12、distribution throughout the flowsystem at some particular time corresponding to the antecedenthydrologic conditions in the aquifer system.3The specifiedheads can be considered reference heads; calculated changes inhead through time will be relative to these given heads, and thetime represented by th
13、ese heads becomes the reference time.As a convenience, this reference time is usually specified aszero time or initial time. Time is reckoned from this zero timeor initial time. In more formal terms, an initial condition giveshead as a function of position at t = 0; that is, h = f (x, y, z; t1This g
14、uide is under the jurisdiction ofASTM Committee D18 on Soil and Rockand is the direct responsibility of Subcommittee D18.21 on Ground Water andVadose Zone Investigations .Current edition approved Sept. 15, 2008. Published October 2008. Originallyapproved in 1994. Last previous edition approved in 20
15、02 as D 5610 94 (2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Franke, O. L., Reilly, T. E., and Ben
16、nett, G. D., “Definition of Boundary andInitial Conditions in the Analysis of Ground-Water Flow SystemsAn Introduc-tion,” Techniques of Water-Resources Investigations of the United States GeologicalSurvey, Book 3, Chapter B5, 1987.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, We
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便