ASTM D5495-2003(2011) Standard Practice for Sampling With a Composite Liquid Waste Sampler (COLIWASA)《混合废水液体采样器(COLIWASA)采样检查的标准操作规程》.pdf
《ASTM D5495-2003(2011) Standard Practice for Sampling With a Composite Liquid Waste Sampler (COLIWASA)《混合废水液体采样器(COLIWASA)采样检查的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5495-2003(2011) Standard Practice for Sampling With a Composite Liquid Waste Sampler (COLIWASA)《混合废水液体采样器(COLIWASA)采样检查的标准操作规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5495 03 (Reapproved 2011)Standard Practice forSampling With a Composite Liquid Waste Sampler(COLIWASA)1This standard is issued under the fixed designation D5495; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice describes the procedure for samplingliquids with the composite liquid waste sampler, or “COLI-WASA.
3、” The COLIWASA is an appropriate device for obtain-ing a representative sample from stratified or unstratifiedliquids. Its most common use is for sampling containerizedliquids, such as tanks, barrels, and drums. It may also be usedfor pools and other open bodies of stagnant liquid.NOTE 1Alimitation
4、of the COLIWASAis that the stopper mechanismmay not allow collection of approximately the bottom inch of material,depending on construction of the stopper.1.2 The COLIWASA should not be used to sample flowingor moving liquids.1.3 The values stated in SI units are to be regarded asstandard. No other
5、units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety problems, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of r
6、egulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D4687 Guide for General Planning of Waste SamplingD5088 Practice for Decontamination of Field EquipmentUsed at Waste SitesD5283 Practice for Generation of Environmental Data Re-lated to Waste Management Activities: Quality
7、 Assuranceand Quality Control Planning and ImplementationD5743 Practice for Sampling Single or Multilayered Liq-uids, With or Without Solids, in Drums or Similar Con-tainersD6232 Guide for Selection of Sampling Equipment forWaste and Contaminated Media Data Collection Activities3. Summary of Practic
8、e3.1 A clean device is slowly lowered into the liquid to besampled. After it has filled, the bottom of the sampling tube isclosed and the device is retrieved. The contents are subse-quently discharged into a sample container.4. Significance and Use4.1 This practice is applicable to sampling liquid w
9、astes andother stratified liquids. The COLIWASA is used to obtain avertical column of liquid representing an accurate cross-sectionof the sampled material. To obtain a representative sample ofstratified liquids, the COLIWASA should be open at both endsso that material flows through it as it is slowl
10、y lowered to thedesired sampling depth. The COLIWASA must not be loweredwith the stopper in place. Opening the stopper after the tube issubmerged will cause material to flow in from the bottom layeronly, resulting in gross over-representation of that layer.4.2 This practice is to be used by personne
11、l acquiringsamples.4.3 This practice should be used in conjunction with GuideD4687 which covers sampling plans, safety, QA, preservation,decontamination, labeling and chain-of-custody procedures;Practice D5088 which covers decontamination of field equip-ment used at waste sites; Practice D5283 which
12、 covers projectspecifications and practices for environmental field operations,and Practice D5743 which covers drum sampling5. Sampling Equipment5.1 COLIWASAs are available commercially with differenttypes of stoppers and locking mechanisms, but they all operateusing the same principle. They can als
13、o be constructed frommaterials such as polyvinylchloride (PVC), glass, metal, orpolytetrafluoroethylene (PTFE). A traditional model of theCOLIWASAis shown in Fig. 1 de Vera et al.3 ,4; however, the1This practice is under the jurisdiction of ASTM Committee D34 on WasteManagement and is the direct res
14、ponsibility of Subcommittee D34.01.03 onSampling Equipment.Current edition approved July 1, 2011. Published September 2011. Originallyapproved in 1994. Last previous edition approved in 2007 as D5495-03 (2007).DOI: 10.1520/D5495-03R11.2For referenced ASTM standards, visit the ASTM website, www.astm.
15、org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3de Vera, E. R., Simmons, B. P., Stephens, R. C., and Storm, D. L., “Samplersand Sampling Procedures for Hazardous Waste Strea
16、ms,” EPA-600/2-80-018,January 1980.4Ford, P. J., Turina, P. J., and Seeley, D. E., “Characterization of HazardousWaste SitesAMethods Manual: Volume II,”Available Sampling Methods, SecondEdition, EPA-600/4-84-076, December 1984.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West C
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便