1、Designation: D3375 16D3375 18Standard Test Method forColumn Capacity of Particulate Mixed Bed IonExchange Materials1This standard is issued under the fixed designation D3375; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、 of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the performance of particulate mixed bed ion exchange materials in th
3、eregenerated form when used for deionization. It is intended for use in testing unused mixed bed materials and samples ofregenerated mixed beds from operating units.1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversionsto inch-p
4、ound units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety safety, health, and health
5、environmental practices and determine theapplicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standa
6、rds, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D1125 Test Methods for Electrical Conductivity and Resistivity of WaterD1129 Terminology Relating to WaterD1193 Specification for Reagent Water
7、D1293 Test Methods for pH of WaterD1782 Test Methods for Operating Performance of Particulate Cation-Exchange MaterialsD2687 Practices for Sampling Particulate Ion-Exchange Materials3. Terminology3.1 DefinitionsFor definitions of terms related to water, refer to Terminology D1129.4. Summary of Test
8、Method4.1 This test method consists of exhausting a column of regenerated mixed bed ion exchange material to a specific end pointwith an influent solution of known composition and volume.5. Significance and Use5.1 This test method can be used to evaluate unused mixed bed ion exchange materials for c
9、onformance to specifications. Whena representative sample of the mixed bed can be obtained from an operating unit, this test method can be used to evaluate theregeneration efficiency by comparison with the same data obtained with new material from the same manufactured lots, or retainedsamples of th
10、e in-place products.5.2 This test method provides for the calculation of capacity in terms of the volume of water treated to a conductivity end point.1 This test method is under the jurisdiction of ASTM Committee D19 on Water and is the direct responsibility of Subcommittee D19.08 on Membranes and I
11、on ExchangeMaterials.Current edition approved July 1, 2016May 1, 2018. Published July 2016May 2018. Originally approved in 1975. Last previous edition approved in 20072016 asD3375 95a (2007).D3375 16. DOI: 10.1520/D3375-16.10.1520/D3375-18.2 For referencedASTM standards, visit theASTM website, www.a
12、stm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what
13、changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the o
14、fficial document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.3 The test method as written assumes that the cation exchange material has been regenerated to the hydrogen form with acidand the anion exchange material has been rege
15、nerated with alkali to the hydroxide or free-base form. In certain applications acation exchange material in the potassium, ammonium, or other monovalent form may be encountered. Such materials may betested following this procedure using Test Water A (Test Methods D1782) as the influent and substitu
16、ting the hardness end point(Test Methods D1782) for the end points prescribed herein.5.4 In most cases the product tested will be properly mixed and will contain the correct proportions of anion and cationexchange materials. However, if the pH as well as the conductivity of the effluent is measured,
17、 the test method will indicate whichof the components is present in excess; an acid effluent at breakthrough indicating an excess of regenerated cation exchange groupsand an alkaline effluent an excess of regenerated anion exchange groups. In such cases the volumes of the two components obtainedin t
18、he final backwash will indicate whether this imbalance arises from improper regeneration or from an improper ratio of the twocomponents. It should be noted, however, that not all units are charged with a balanced ratio of anion-exchanging andcation-exchanging groups. Hence, wherever possible, a fiel
19、d sample should be evaluated in comparison with a retained sample ofthe original charge.5.5 This test method provides for the calculation of capacity on either a wet weight basis or a volume basis. Although suchmaterials are normally bought and sold in terms of cubic feet, they are actually packaged
20、 in wet pounds.Therefore, it is the capacityon a wet weight basis that is directly correlatable to the amount of material in a given shipment.5.6 Calculation of a volume capacity is based on the exhausted, separated volume of the components after backwashing andresettling the bed. This volume is cho
21、sen because it is difficult, if not impossible, to pack a sample of regenerated mixed bedmaterial in a small-diameter column reproducibly.5.7 This test method may be used to test mixed bed resin cartridges. In such cases the flow rate of test water and the frequencyof sampling must be varied to comp
22、ensate for the approximate volume of resin in the test sample. The test as written assumes aresin volume of approximately 330 mL.6. Apparatus6.1 Test Assembly (Fig. 1), consisting of the following:6.1.1 Column, transparent supported 2.5 6 0.25-cm (1 6 0.1-in.) inside diameter and approximately 150 c
23、m (60 in.) long. Thebottom of the column shall be closed and provided with an outlet of about 6-mm inside diameter. Connections shall be providedat the top and the bottom for the admission and removal of the exhausting solution as described in 7.4. Adequate means ofregulating and measuring flow shal
24、l be provided. Support for the sample shall be provided so that the distance from the sampleto the column outlet is at least 5 cm. Calibrate the column in such a manner that the volume readings required by the test methodcan be made. Make all calibration measurements at 25 6 5C.6.1.2 Sample Support,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD33752018STANDARDTESTMETHODFORCOLUMNCAPACITYOFPARTICULATEMIXEDBEDIONEXCHANGEMATERIALSPDF

链接地址:http://www.mydoc123.com/p-514684.html