1、Designation: D61 15Standard Test Method forSoftening Point of Pitches (Cube-in-Water Method)1This standard is issued under the fixed designation D61; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last revision. A numb
2、er in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of the soft-ening point of pitches below 176 F (80 C). Pitches of highersoftening point should b
3、e tested by Test Method D2319 or TestMethod D3104.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard does not purport
4、to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D140 Pr
5、actice for Sampling Bituminous MaterialsD2319 Test Method for Softening Point of Pitch (Cube-in-Air Method)D3104 Test Method for Softening Point of Pitches (MettlerSoftening Point Method)E1 Specification for ASTM Liquid-in-Glass ThermometersE563 Practice for Preparation and Use of an Ice-Point Batha
6、s a Reference TemperatureE1137 Specification for Industrial Platinum Resistance Ther-mometersE2251 Specification for Liquid-in-Glass ASTM Thermom-eters with Low-Hazard Precision LiquidsE2877 Guide for Digital Contact Thermometers3. Terminology3.1 Definitions:3.1.1 Digital Contact Thermometer (DCT),
7、nan electronicdevice consisting of a digital display and associated tempera-ture sensing probe.3.1.1.1 DiscussionThis device consists of a temperaturesensor connected to a measuring instrument; this instrumentmeasures the temperature-dependent quantity of the sensor,computes the temperature from the
8、 measured quantity, andprovides a digital output or display, or both, of the temperature.The temperature sensing probe is in contact with the materialwhose temperature is being measured. This device is some-times referred to as a digital thermometer.NOTE 1Portable electronic thermometers (PET) is an
9、 acronym some-times used to refer to a subset of the devices covered by this definition.4. Summary of Test Method4.1 Two cubes of pitch, supported on wire hooks, are heatedat a controlled rate in water in a glass container. The softeningpoint is defined as the mean of the temperatures at which thecu
10、bes sag downwards a distance of 25 mm.5. Significance and Use5.1 Pitch does not go through a solid-liquid phase changewhen heated, and therefore it does not have a true meltingpoint. As the temperature rises, pitch softens and becomes lessviscous. The softening point is arbitrarily defined and shall
11、 beestablished by a closely controlled method which shall becarefully followed if test results are to be reproducible.5.2 This test is useful in determining the consistency ofpitch as one element in establishing the uniformity of ship-ments or sources of supply.6. Apparatus6.1 MoldA mold suitable fo
12、r forming two12 in.(12.7 mm) cubes of pitch, having cylindrical core pins 12gauge (2.05 mm) in diameter located in the base plate of theassembly to produce accurately centered suspension holes inthe cubes. (See Fig. 1.)6.2 HooksTwo L-shaped hooks, made of 12 gauge(2.05 mm) copper wire. The foot of t
13、he hook shall be 1 in.(25 mm) long and at a right angle to the upright portion forinsertion into the center hole of the pitch cube.6.3 ContainerA glass vessel that can be heated, not lessthan 85 mm in diameter and 105 mm deep. (Astandard 600 mLlow-form beaker meets these requirements).1This test met
14、hod is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricantsand is the direct responsibility ofSubcommittee D02.05 on Properties of Fuels, Petroleum Coke and Carbon Material.Current edition approved July 1, 2015. Published July 2015. Originally approvedin 19
15、19. Last previous edition approved in 2010 as D61 75 (2010). DOI:10.1520/D0061-15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary pag
16、e onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16.4 Temperature Measuring DeviceUse either a calibratedDCT meeting the requirements described in 6.4
17、.1 or liquid-in-glass thermometers described in 6.4.2. A DCT or calibratedliquid-in-glass thermometer shall be used as the thermometerfor temperature measurement independent of the instrumentstemperature control, and shall be located in the thermowell.NOTE 2The display device and sensor must be corr
18、ectly paired.Incorrect pairing will result in temperature measurement errors andpossibly irreversible damage to the electronics of the display.FIG. 1 Apparatus for Cube-in-Water MethodD611526.4.1 Digital Contact Thermometer Requirements:Criteria RequirementsDCT E2877 Class E, MinimumTemperature rang
19、e 2 C to 80 CDisplay resolution 0.1 CSensor type PRT, thermistor, Type E or T thermocoupleSensor, sheath Metal or glassSensor length Less than 12 mm in lengthImmersion depth 76 mmDisplay accuracy 0.2 C for combined probe and sensorResponse time Less than or equal to 30 s as defined in Specifica-tion
20、 E1137Drift Less than 0.2 C per yearCalibration error Less than 0.2 C over the range of intended useCalibration range 2 C to 80 CCalibration data 4 data points evenly distributed over the rangeand included in calibration reportCalibration report From a calibration laboratory with demonstratedcompete
21、ncy in temperature calibration which istraceable to a national calibration laboratory ormetrology standards body6.4.1.1 The DCT calibration drift shall be checked at leastannually by either measuring the ice point or against areference thermometer in a constant temperature bath at theprescribed imme
22、rsion depth to ensure compliance with 6.4.1.With respect to an ice bath, Practice E563 provides guidanceon the preparation and use of an ice bath. However, for this use,variance from the specific steps, such as water source, ispermitted provided preparation is consistent. The basis for thevariance i
23、s due to the ice bath reference being used for trackingchange in calibration not verification.NOTE 3When a DCTs calibration drifts in one direction over severalcalibration checks, that is, ice point, it may be an indication of deteriora-tion of the DCT.6.4.2 An ASTM Low Softening Point Thermometer h
24、avinga range from 2 C to 80 C and conforming to therequirements for Thermometer 15 as described in SpecificationE1 or E2251.6.4.2.1 Calibration CheckVerify thermometer at least an-nually against a reference thermometer in a constant tempera-ture bath or an ice bath. The thermometer is to be inserted
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD612015STANDARDTESTMETHODFORSOFTENINGPOINTOFPITCHESCUBEINWATERMETHOD 硬沥青 软化 标准 试验 方法 水中 方块 PDF

链接地址:http://www.mydoc123.com/p-511946.html