ASTM D1824-1995(2010) Standard Test Method for Apparent Viscosity of Plastisols and Organosols at Low Shear Rates《在低剪切速率下塑料溶胶和有机溶胶的表观粘度的标准试验方法》.pdf
《ASTM D1824-1995(2010) Standard Test Method for Apparent Viscosity of Plastisols and Organosols at Low Shear Rates《在低剪切速率下塑料溶胶和有机溶胶的表观粘度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1824-1995(2010) Standard Test Method for Apparent Viscosity of Plastisols and Organosols at Low Shear Rates《在低剪切速率下塑料溶胶和有机溶胶的表观粘度的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1824 95 (Reapproved 2010)Standard Test Method forApparent Viscosity of Plastisols and Organosols at LowShear Rates1This standard is issued under the fixed designation D1824; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revis
2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method cov
3、ers the measurement of plastisoland organosol viscosity at low shear rates.1.2 Apparent viscosity at high shear rates is covered in TestMethod D1823.1.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not
4、 purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1This test method resembles ISO 3219
5、-1977 in title only. Thecontent is significantly different.2. Referenced Documents2.1 ASTM Standards:2D1755 Specification for Poly(Vinyl Chloride) ResinsD1823 Test Method forApparent Viscosity of Plastisols andOrganosols at High Shear Rates by Extrusion ViscometerE1 Specification for ASTM Liquid-in-
6、Glass ThermometersE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 ISO Standard:ISO 3219-1977: Polymers in the Liquid, Emulsified, orDispersed StateDetermination of Viscosity With a Ro-tational Viscometer Working at a Defined Shear Rate33. Summary o
7、f Test Method3.1 The sample is conditioned to the proper temperature andits viscosity is determined.4. Significance and Use4.1 The suitability of a dispersion resin for any givenapplication process is dependent upon its viscosity character-istics.4.2 The viscosity defines the flow behavior of a plas
8、tisol ororganosol under low shear. This viscosity relates to theconditions encountered in pouring, casting, molding, anddipping processes.5. Apparatus5.1 Viscometer.45.2 Sample Containers, Tin Cans, or Glass Jars, 1-pt(500-mL) capacity. Minimum dimensions of containers shouldbe 80-mm (3.15-in.) insi
9、de diameter by 80 mm (3.15 in.) deep.5.3 Thermometer, ASTM Solvents Distillation Thermom-eter having a range from 2 to + 52C (28 to 126F) andconforming to the requirements for Thermometer 37C asprescribed in Specification E1.5.4 Timer.6. Conditioning6.1 Maintain the plastisol or organosol samples at
10、 23 6 1C(73 6 2F) and 50 6 5 % relative humidity at all times aftermixing and throughout the period of viscosity determinations.1This test method is under the jurisdiction ofASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.15 on Thermoplastic Materi-als.Current edit
11、ion approved Dec. 15, 2010. Published March 2011. Originallyapproved in 1961. Last previous edition approved in 2002 as D1824 - 95(2002).DOI:10.1520/D1824-95R10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book o
12、f ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.4Brookfield model RVF or LVF, or equivalent has been found satisfactory f
13、orthis purpose. Brookfield Engnrg. Labs, Inc., Stoughton, MA 02072.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7. Procedure7.1 Select a spindle that will read in the middle or upperportion of the viscometer dial at the highest ro
14、tational speed tobe used. Insert the spindle into the sample at approximately a45 angle. Withdraw the spindle and attach it to the viscometer.Taking care not to entrap an air bubble, lower the viscometer toimmerse the spindle near the edge of the sample. Move thesample so as to center the spindle. A
15、djust its depth to theimmersion mark.7.2 Start the viscometer at its lowest speed. Allow it to run2 min. Record the scale reading during the next rotation.Without stopping the viscometer, switch to the next higherspeed. Record the scale readings after 2 min at each speed inorder from the lowest to t
16、he highest speeds.7.3 Record the sample temperature at the conclusion ofviscosity readings.8. Calculation8.1 Calculate the viscosity using the factors provided withthe viscometer.9. Report9.1 Report the following information:9.1.1 Complete sample identification.9.1.2 Temperature of the sample.9.1.3
17、Viscometer model and spindle number used for test.9.1.4 Viscosity at each spindle speed used.9.1.5 Sample conditioning time.NOTE 2If only one viscosity is to be reported, record as the viscosity,the poises at 20 rpm for Model RVF, or at 60 rpm for Model LVF, togetherwith the aging period, viscometer
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD182419952010STANDARDTESTMETHODFORAPPARENTVISCOSITYOFPLASTISOLSANDORGANOSOLSATLOWSHEARRATES 剪切 速率

链接地址:http://www.mydoc123.com/p-510521.html