ASTM C665-2012 Standard Specification for Mineral-Fiber Blanket Thermal Insulation for Light Frame Construction and Manufactured Housing 《轻型框架结构和预制房屋矿物纤维隔热毯的标准规格》.pdf
《ASTM C665-2012 Standard Specification for Mineral-Fiber Blanket Thermal Insulation for Light Frame Construction and Manufactured Housing 《轻型框架结构和预制房屋矿物纤维隔热毯的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C665-2012 Standard Specification for Mineral-Fiber Blanket Thermal Insulation for Light Frame Construction and Manufactured Housing 《轻型框架结构和预制房屋矿物纤维隔热毯的标准规格》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C665 12Standard Specification forMineral-Fiber Blanket Thermal Insulation for Light FrameConstruction and Manufactured Housing1This standard is issued under the fixed designation C665; the number immediately following the designation indicates the year oforiginal adoption or, in the cas
2、e of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This speci
3、fication covers the composition and physicalproperties of mineral-fiber blanket insulation used to thermallyor acoustically insulate ceilings, floors, and walls in light frameconstruction and manufactured housing. The requirementscover fibrous blankets and facings. Values for water-vaporpermeance of
4、 facings are suggested for information that will behelpful to designers and installers.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standar
5、d.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced
6、 Documents2.1 ASTM Standards:2B152/B152M Specification for Copper Sheet, Strip, Plate,and Rolled BarC167 Test Methods for Thickness and Density of Blanket orBatt Thermal InsulationsC168 Terminology Relating to Thermal InsulationC177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Tr
7、ansmission Properties by Means ofthe Guarded-Hot-Plate ApparatusC390 Practice for Sampling and Acceptance of ThermalInsulation LotsC518 Test Method for Steady-State Thermal TransmissionProperties by Means of the Heat Flow Meter ApparatusC653 Guide for Determination of the Thermal Resistance ofLow-De
8、nsity Blanket-Type Mineral Fiber InsulationC1104/C1104M Test Method for Determining the WaterVapor Sorption of Unfaced Mineral Fiber InsulationC1304 Test Method for Assessing the Odor Emission ofThermal Insulation MaterialsC1338 Test Method for Determining Fungi Resistance ofInsulation Materials and
9、 FacingsC1617 Practice for Quantitative Accelerated LaboratoryEvaluation of Extraction Solutions Containing IonsLeached from Thermal Insulation on Aqueous Corrosionof MetalsE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE96/E96M Test Methods for Water Vapor Transmission ofMa
10、terialsE970 Test Method for Critical Radiant Flux of ExposedAttic Floor Insulation Using a Radiant Heat Energy SourceG1 Practice for Preparing, Cleaning, and Evaluating Corro-sion Test Specimens3. Terminology3.1 DefinitionsFor definitions of terms used in this speci-fication, see Terminology C168.4.
11、 Classification4.1 Typical mineral-fiber thermal insulation is classified intothe following types, classes, and categories:4.1.1 Type IBlankets without facings.4.1.2 Type IIBlankets with nonreflective facings.4.1.2.1 Class AFacing with a flame spread index of 25 orless.(1) Category 1Facing is a vapo
12、r retarder.(2) Category 2Facing is not a vapor retarder.4.1.2.2 Class BFacing with a flame propagation resis-tance; critical radiant flux of 0.12 W/cm2(.11 Btu/ft2s) orgreater.(1) Category 1Facing is a vapor retarder.1This specification is under the jurisdiction of ASTM Committee C16 onThermal Insul
13、ation and is the direct responsibility of Subcommittee C16.23 onBlanket and Loose Fill Insulation.Current edition approved May 1, 2012. Published June 2012. Originallyapproved in 1970. Last previous edition approved in 2006 as C665 06. DOI:10.1520/C0665-11.2For referenced ASTM standards, visit the A
14、STM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, Uni
15、ted States.(2) Category 2Facing is not a vapor retarder.4.1.2.3 Class CFacing not rated for flame propagationresistance (for use in nonexposed applications only).(1) Category 1Facing is a vapor retarder.(2) Category 2Facing is not a vapor retarder.4.1.3 Type IIIBlankets with reflective facings:4.1.3
16、.1 Class AFacing with a flame spread index of 25 orless.(1) Category 1Facing is a vapor retarder.(2) Category 2Facing is not a vapor retarder.4.1.3.2 Class BFacing with a flame propagation resis-tance; critical radiant flux of 0.12 W/cm2(.11 Btu/ft2s) orgreater.(1) Category 1Facing is a vapor retard
17、er.(2) Category 2Facing is not a vapor retarder.4.1.3.3 Class CFacing not rated for flame propagationresistance (for use in nonexposed applications only).(1) Category 1Facing is a vapor retarder.(2) Category 2Facing is not a vapor retarder.4.2 Mechanically attached field installed facing shall becla
18、ssified into Type/Class/Category as follows:(1) Type I insulation used in conjunction with a fieldinstalled non-reflective facing having a 25 flame spread or lesson both sides is considered functionally equivalent to a TypeII/Class A/Category 1 insulation composite.(2) Type I insulation used in conj
19、unction with a field-installed perforated, or vapor breathable, nonreflective facinghaving a 25 flame spread or less on both sides is consideredfunctionally equivalent to Type II/Class A/Category 2 insula-tion composite.(3) Type I insulation used in conjunction with a field-installed reflective faci
20、ng (reflective side exposed) having a 25flame spread or less on both sides is considered equivalent toa Type III/Class A/Category 1 insulation composite.(4) Type I insulation used in conjunction with a field-installed perforated, or vapor breathable, reflective facing(reflective side exposed) having
21、 a 25 flame spread or less onboth sides is considered functionally equivalent to a TypeIII/Class A/Category 2 insulation composite.5. Ordering Information5.1 For specific installations, thermal resistance, length,width, and facing suited to the intended use shall be specifiedby the purchaser.6. Mate
22、rials and Manufacture6.1 Basic MaterialThe basic material shall be fibers madefrom mineral substances such as rock, slag, or glass processedfrom the molten state into a fibrous form.6.2 ManufactureInsulation blankets shall consist of flex-ible units composed of felted, bonded, or unbonded fibersform
23、ed into rolls or flat cut pieces (batts), with or withoutvarious adhered facings, and with or without a means forattachment of the blanket to applicable constructions.7. Physical Properties7.1 Thermal ResistanceThe standard thermal resistancevalues in Fhft2/Btu (K m2/W) are: 4, 7, 11, 13, 19, 22,30,
24、 and 38 (0.7, 1.2, 1.9, 2.3, 3.3, 3.9, 5.3, and 6.7). R valuesother than those listed shall be agreed upon between thesupplier and the purchaser. The product must be produced tothe label R value. The thermal resistance, R, for the average ofany four randomly selected samples shall not be more than 5
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC6652012STANDARDSPECIFICATIONFORMINERALFIBERBLANKETTHERMALINSULATIONFORLIGHTFRAMECONSTRUCTIONANDMANUFACTUREDHOUSING

链接地址:http://www.mydoc123.com/p-507956.html