《ASTM C665-2011 Standard Specification for Mineral-Fiber Blanket Thermal Insulation for Light Frame Construction and Manufactured Housing《轻型框架结构和预制房屋矿物纤维隔热毯的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C665-2011 Standard Specification for Mineral-Fiber Blanket Thermal Insulation for Light Frame Construction and Manufactured Housing《轻型框架结构和预制房屋矿物纤维隔热毯的标准规范》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C665 11Standard Specification forMineral-Fiber Blanket Thermal Insulation for Light FrameConstruction and Manufactured Housing1This standard is issued under the fixed designation C665; the number immediately following the designation indicates the year oforiginal adoption or, in the cas
2、e of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This speci
3、fication covers the composition and physicalproperties of mineral-fiber blanket insulation used to thermallyor acoustically insulate ceilings, floors, and walls in light frameconstruction and manufactured housing. The requirementscover fibrous blankets and facings. Values for water-vaporpermeance of
4、 facings are suggested for information that will behelpful to designers and installers.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standar
5、d.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced
6、 Documents2.1 ASTM Standards:2B152/B152M Specification for Copper Sheet, Strip, Plate,and Rolled BarC167 Test Methods for Thickness and Density of Blanket orBatt Thermal InsulationsC168 Terminology Relating to Thermal InsulationC177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Tr
7、ansmission Properties by Means ofthe Guarded-Hot-Plate ApparatusC390 Practice for Sampling and Acceptance of ThermalInsulation LotsC518 Test Method for Steady-State Thermal TransmissionProperties by Means of the Heat Flow Meter ApparatusC653 Guide for Determination of the Thermal Resistance ofLow-De
8、nsity Blanket-Type Mineral Fiber InsulationC1104/C1104M Test Method for Determining the WaterVapor Sorption of Unfaced Mineral Fiber InsulationC1304 Test Method for Assessing the Odor Emission ofThermal Insulation MaterialsC1338 Test Method for Determining Fungi Resistance ofInsulation Materials and
9、 FacingsC1617 Practice for Quantitative Accelerated LaboratoryEvaluation of Extraction Solutions Containing IonsLeached from Thermal Insulation on Aqueous Corrosionof MetalsE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE96/E96M Test Methods for Water Vapor Transmission ofMa
10、terialsE970 Test Method for Critical Radiant Flux of ExposedAttic Floor Insulation Using a Radiant Heat Energy SourceG1 Practice for Preparing, Cleaning, and Evaluating Corro-sion Test Specimens3. Terminology3.1 DefinitionsFor definitions of terms used in this speci-fication, see Terminology C168.4.
11、 Classification4.1 Typical mineral-fiber thermal insulation is classified intothe following types, classes, and categories:4.1.1 Type IBlankets without facings.4.1.2 Type IIBlankets with nonreflective facings.4.1.2.1 Class AFacing with a flame spread index of 25 orless.4.1.2.2 Class BFacing with a f
12、lame propagation resis-tance; critical radiant flux of 0.12 W/cm2(.11 Btu/ft2s) orgreater.4.1.2.3 Class CFacing not rated for flame propagationresistance (for use in nonexposed applications only).4.1.2.4 Category 1Facing is a vapor retarder.1This specification is under the jurisdiction of ASTM Commi
13、ttee C16 onThermal Insulation and is the direct responsibility of Subcommittee C16.23 onBlanket and Loose Fill Insulation.Current edition approved Nov. 15, 2011. Published December 2011. Originallyapproved in 1970. Last previous edition approved in 2006 as C665 06. DOI:10.1520/C0665-11.2For referenc
14、ed ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Co
15、nshohocken, PA 19428-2959, United States.4.1.2.5 Category 2Facing is not a vapor retarder.4.1.3 Type IIIBlankets with reflective facings:4.1.3.1 Class AFacing with a flame spread index of 25 orless.4.1.3.2 Class BFacing with a flame propagation resis-tance; critical radiant flux of 0.12 W/cm2(.11 Bt
16、u/ft2s) orgreater.4.1.3.3 Class CFacing not rated for flame propagationresistance (for use in nonexposed applications only).4.1.3.4 Category 1Facing is a vapor retarder.4.1.3.5 Category 2Facing is not a vapor retarder.5. Ordering Information5.1 For specific installations, thermal resistance, length,
17、width, and facing suited to the intended use shall be specifiedby the purchaser.6. Materials and Manufacture6.1 Basic Material The basic material shall be fibersmade from mineral substances such as rock, slag, or glassprocessed from the molten state into a fibrous form.6.2 Manufacture Insulation bla
18、nkets shall consist of flex-ible units composed of felted, bonded, or unbonded fibersformed into rolls or flat cut pieces (batts), with or withoutvarious adhered facings, and with or without a means forattachment of the blanket to applicable constructions.7. Physical Properties7.1 Thermal Resistance
19、The standard thermal resistancevalues in Fhft2/Btu (K m2/W) are: 4, 7, 11, 13, 19, 22,30, and 38 (0.7, 1.2, 1.9, 2.3, 3.3, 3.9, 5.3, and 6.7). R valuesother than those listed shall be agreed upon between thesupplier and the purchaser. The product must be produced tothe label R value. The thermal res
20、istance, R, for the average ofany four randomly selected samples shall not be more than 5 %below the listed R value when tested in accordance with 13.2,nor shall any single specimen be more than 10 % below thelisted R value.7.2 Surface Burning Characteristics:7.2.1 Insulation blankets exclusive of f
21、acing, when tested inaccordance with Test Method E84, shall have a flame spreadindex no greater than 25, and a smoke developed index nogreater than 50.7.2.2 Insulation blankets with facings intended for exposedapplication, when tested in accordance with Test Method E84,shall have a flame spread inde
22、x no greater than 25, and a smokedeveloped index no greater than 50.7.3 Critical Radiant FluxInsulation blankets, when testedin accordance with 13.4, shall have a critical radiant flux-flamepropagation resistance$0.12 W/cm2(0.11 Btu/ft2s). Blanketswith facing on both surfaces, shall be tested on the
23、 surface tobe left exposed and shall be marked on either surface.7.4 Water-Vapor PermeanceWhen tested in accordancewith 13.5, vapor retardant facings shall have a vapor per-meance of no more than 1 perm(5.7 3 1011kgPa1s1m2) and vapor-permeable facingshall have a vapor permeance of no less than 5 per
24、m(2.9 3 1010kgPa1s1m2).7.5 Water Vapor SorptionThe water vapor sorption of theinsulation without facing shall be not more than 5 % by weight,when tested in accordance with 13.6.7.6 Odor EmissionAdetectable odor of strong objection-able nature recorded by more than two of the five panelmembers shall
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC6652011STANDARDSPECIFICATIONFORMINERALFIBERBLANKETTHERMALINSULATIONFORLIGHTFRAMECONSTRUCTIONANDMANUFACTUREDHOUSING

链接地址:http://www.mydoc123.com/p-507955.html