ASTM C665-2006 Standard Specification for Mineral-Fiber Blanket Thermal Insulation for Light Frame Construction and Manufactured Housing《轻型结构和人造框架用矿质纤维毡绝热材料标准规范》.pdf
《ASTM C665-2006 Standard Specification for Mineral-Fiber Blanket Thermal Insulation for Light Frame Construction and Manufactured Housing《轻型结构和人造框架用矿质纤维毡绝热材料标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C665-2006 Standard Specification for Mineral-Fiber Blanket Thermal Insulation for Light Frame Construction and Manufactured Housing《轻型结构和人造框架用矿质纤维毡绝热材料标准规范》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 665 06Standard Specification forMineral-Fiber Blanket Thermal Insulation for Light FrameConstruction and Manufactured Housing1This standard is issued under the fixed designation C 665; the number immediately following the designation indicates the year oforiginal adoption or, in the c
2、ase of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This sp
3、ecification covers the composition and physicalproperties of mineral-fiber blanket insulation used to thermallyor acoustically insulate ceilings, floors, and walls in light frameconstruction and manufactured housing. The requirementscover fibrous blankets and facings. Values for water-vaporpermeance
4、 of facings are suggested for information that will behelpful to designers and installers.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are providedfor information only.1.3 This standard does not purport to address all of thesafety conce
5、rns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2B 152/B 152M Specification for Copper Sh
6、eet, Strip, Plate,and Rolled BarC 167 Test Methods for Thickness and Density of Blanketor Batt Thermal InsulationsC 168 Terminology Relating to Thermal InsulationC 177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded-Hot-Plate ApparatusC
7、 390 Practice for Sampling and Acceptance of ThermalInsulation LotsC 518 Test Method for Steady-State Thermal TransmissionProperties by Means of the Heat Flow Meter ApparatusC 653 Guide for Determination of the Thermal Resistanceof Low-Density Blanket-Type Mineral Fiber InsulationC 1104/C 1104M Test
8、 Method for Determining the WaterVapor Sorption of Unfaced Mineral Fiber InsulationC 1304 Test Method for Assessing the Odor Emission ofThermal Insulation MaterialsC 1338 Test Method for Determining Fungi Resistance ofInsulation Materials and FacingsE84 Test Method for Surface Burning Characteristic
9、s ofBuilding MaterialsE 96/E 96M Test Methods for Water Vapor Transmission ofMaterialsE 970 Test Method for Critical Radiant Flux of ExposedAttic Floor Insulation Using a Radiant Heat Energy SourceG1 Practice for Preparing, Cleaning, and Evaluating Cor-rosion Test Specimens3. Terminology3.1 Definiti
10、onsFor definitions of terms used in this speci-fication, see Terminology C 168.4. Classification4.1 Typical mineral-fiber thermal insulation is classified intothe following types, classes, and categories:4.1.1 Type IBlankets without facings.4.1.2 Type IIBlankets with nonreflective facings.4.1.2.1 Cl
11、ass AFacing with a flame spread index of 25 orless.4.1.2.2 Class BFacing with a flame propagation resis-tance; critical radiant flux of 0.12 W/cm2(.11 Btu/ft2s) orgreater.4.1.2.3 Class CFacing not rated for flame propagationresistance (for use in nonexposed applications only).4.1.2.4 Category 1Facin
12、g is a vapor retarder.4.1.2.5 Category 2Facing is not a vapor retarder.4.1.3 Type IIIBlankets with reflective facings:4.1.3.1 Class AFacing with a flame spread index of 25 orless.4.1.3.2 Class BFacing with a flame propagation resis-tance; critical radiant flux of 0.12 W/cm2(.11 Btu/ft2s) orgreater.4
13、.1.3.3 Class CFacing not rated for flame propagationresistance (for use in nonexposed applications only).1This specification is under the jurisdiction of ASTM Committee C16 onThermal Insulation and is the direct responsibility of Subcommittee C16.23 onBlanket and Loose Fill Insulation.Current editio
14、n approved May 1, 2006. Published May 2006. Originallyapproved in 1970. Last previous edition approved in 2001 as C 665 01e1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information,
15、refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.1.3.4 Category 1Facing is a vapor retarder.4.1.3.5 Category 2Facing is not a vapor retarder.5. Ordering Information5.1
16、For specific installations, thermal resistance, length,width, and facing suited to the intended use shall be specifiedby the purchaser.6. Materials and Manufacture6.1 Basic Material The basic material shall be fibersmade from mineral substances such as rock, slag, or glassprocessed from the molten s
17、tate into a fibrous form.6.2 Manufacture Insulation blankets shall consist of flex-ible units composed of felted, bonded, or unbonded fibersformed into rolls or flat cut pieces (batts), with or withoutvarious adhered facings, and with or without a means forattachment of the blanket to applicable con
18、structions.7. Physical Properties7.1 Thermal ResistanceThe standard thermal resistancevalues in Fhft2/Btu (K m2/W) are: 4, 7, 11, 13, 19, 22,30, and 38 (0.7, 1.2, 1.9, 2.3, 3.3, 3.9, 5.3, and 6.7). R valuesother than those listed shall be agreed upon between thesupplier and the purchaser. The produc
19、t must be produced tothe label R value. The thermal resistance, R, for the average ofany four randomly selected samples shall not be more than 5 %below the listed R value when tested in accordance with 13.2,nor shall any single specimen be more than 10 % below thelisted R value.7.2 Surface Burning C
20、haracteristics:7.2.1 Insulation blankets exclusive of facing, when tested inaccordance with Test Method E84, shall have a flame spreadindex no greater than 25, and a smoke developed index nogreater than 50.7.2.2 Insulation blankets with facings intended for exposedapplication, when tested in accorda
21、nce with Test Method E84,shall have a flame spread index no greater than 25, and a smokedeveloped index no greater than 50.7.3 Critical Radiant FluxInsulation blankets, when testedin accordance with 13.4, shall have a critical radiant flux-flamepropagation resistance$0.12 W/cm2(0.11 Btu/ft2s). Blank
22、etswith facing on both surfaces, shall be tested on the surface tobe left exposed and shall be marked on either surface.7.4 Water-Vapor PermeanceWhen tested in accordancewith 13.5, vapor retardant facings shall have a vapor per-meance of no more than 1 perm(5.7 3 1011kgPa1s1m2) and vapor-permeable f
23、acingshall have a vapor permeance of no less than 5 perm(2.9 3 1010kgPa1s1m2).7.5 Water Vapor SorptionThe water vapor sorption of theinsulation without facing shall be not more than 5 % by weight,when tested in accordance with 13.6.7.6 Odor Emission A detectable odor of strong objection-able nature
24、recorded by more than two of the five panelmembers shall constitute rejection of the material when testedin accordance with 13.7.7.7 Corrosiveness When tested in accordance with 13.8,the metal plates in contact with the insulation shall show nocorrosion greater than that observed on the comparative
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC6652006STANDARDSPECIFICATIONFORMINERALFIBERBLANKETTHERMALINSULATIONFORLIGHTFRAMECONSTRUCTIONANDMANUFACTUREDHOUSING

链接地址:http://www.mydoc123.com/p-507954.html