ASTM C1372-2017 Standard Specification for Dry-Cast Segmental Retaining Wall Units《干铸拼装式挡土墙部件的标准规格》.pdf
《ASTM C1372-2017 Standard Specification for Dry-Cast Segmental Retaining Wall Units《干铸拼装式挡土墙部件的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1372-2017 Standard Specification for Dry-Cast Segmental Retaining Wall Units《干铸拼装式挡土墙部件的标准规格》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1372 16C1372 17Standard Specification forDry-Cast Segmental Retaining Wall Units1This standard is issued under the fixed designation C1372; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers dry-cast segmental retaining wall units of concrete, machinemade from hydraulic cement, water,and suitable m
3、ineral aggregates with or without the inclusion of other materials. The units are intended for use in the constructionof mortarless segmental retaining walls.NOTE 1When particular features are desired, such as density classification, higher compressive strength, surface texture, finish, color, or ot
4、her specialfeatures, such properties should be specified separately by the purchaser. Suppliers should be consulted as to availability of units having the desiredfeatures.1.2 The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes(excludi
5、ng those in tables and figures) shall not be considered as requirements of the standard.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered stan
6、dard.1.4 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers
7、to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C33 Specification for Concrete AggregatesC140 Test Methods for Sampling and Testing Concrete Masonry Units and Related UnitsC150 Specification for Portland CementC331 Specification for Lightweight Aggregates for Concrete Masonry Uni
8、tsC595 Specification for Blended Hydraulic CementsC618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in ConcreteC989 Specification for Slag Cement for Use in Concrete and MortarsC1157 Performance Specification for Hydraulic CementC1232 Terminology for MasonryC1262 Test
9、Method for Evaluating the Freeze-Thaw Durability of Dry-Cast Segmental Retaining Wall Units and RelatedConcrete Units3. Terminology3.1 Terminology defined in Terminology C1232 shall apply for this specification.3.2 Definitions:3.2.1 Dry-cast, adjmanufacturing concrete products using low frequency, h
10、igh amplitude vibration to consolidate concrete ofstiff or extremely dry consistency in a form.3.2.2 segmental retaining wall unit, nunit manufactured of concrete for the construction of dry-stacked earth retaining walls.1 This specification is under the jurisdiction of ASTM Committee C15 on Manufac
11、tured Masonry Units and is the direct responsibility of C15.03 on Concrete MasonryUnits and Related Units.Current edition approved June 1, 2016Aug. 1, 2017. Published July 2016August 2017. Originally approved in 1997. Last previous edition approved in 20142016 asC1372 14a.C1372 16. DOI: 10.1520/C137
12、2-16.10.1520/C1372-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard a
13、nd is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only
14、 the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.3 segmental retain
15、ing wall unit, dry-cast, na segmental retaining wall unit manufactured of concrete using a dry-castprocess.4. Materials4.1 Cementitious MaterialsMaterials shall conform to the following applicable specifications:4.1.1 Portland CementsSpecification C150.4.1.2 Modified Portland CementPortland cement c
16、onforming to Specification C150, modified as follows:4.1.2.1 LimestoneLimestone, with a minimum 85 % Calcium Carbonate (CaCO3) content, shall be permitted to be added tothe cement, provided these requirements of Specification C150 as modified are met:(1) Limitation on Insoluble Residue1.5 %.(2) Limi
17、tation on Air Content of MortarVolume percent, 22 % max.(3) Limitation on Loss of Ignition7 %.4.1.3 Blended Hydraulic CementsSpecification C595.4.1.4 Hydraulic CementSpecification C1157.4.1.5 PozzolansSpecification C618.4.1.6 Blast Furnace Slag CementSpecification C989.4.2 AggregatesAggregates shall
18、 conform to the following specifications, except that grading requirements shall notnecessarily apply:4.2.1 Normal Weight AggregatesSpecification C33.4.2.2 Lightweight AggregatesSpecification C331.4.3 Other ConstituentsAir-entraining agents, coloring pigments, integral water repellents, finely groun
19、d silica, and otherconstituents shall be previously established as suitable for use in segmental retaining wall units and shall conform to applicableASTM standards or shall be shown by test or experience to be not detrimental to the durability of the segmental retaining wallunits or any material cus
20、tomarily used in segmental retaining wall construction.5. Physical Requirements5.1 At the time of delivery to the work site, the units shall conform to the physical requirements of Table 1 when tested inaccordance with 8.2. All units shall be sound and free of cracks or other defects that interfere
21、with the proper placement of theunits or significantly impair the strength or permanence of the construction. Minor cracks incidental to the usual method ofmanufacture or minor chipping resulting from customary methods of handling in shipment and delivery are not grounds forrejection.5.1.1 When high
22、er compressive strengths than those listed in Table 1 are specified, the tested average net area compressivestrength of three units shall equal or exceed the specified compressive strength, and the following single unit strength requirementsshall apply.5.1.1.1 When the specified compressive strength
23、 is less than 5000 psi, no single unit net area compressive strength test resultshall be less than the specified compressive strength minus 500 psi.5.1.1.2 When the specified compressive strength is 5000 psi or greater, no single unit net area compressive strength test resultshall be less than 90 %
24、of the specified compressive strength.5.2 Freeze-Thaw DurabilityIn areas where repeated freezing and thawing under saturated conditions occur, freeze-thawdurability shall be demonstrated by test or by proven field performance that the segmental retaining wall units have adequatedurability for the in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC13722017STANDARDSPECIFICATIONFORDRYCASTSEGMENTALRETAININGWALLUNITS 拼装 挡土墙 部件 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-464393.html