1、Designation: C1372 14aC1372 16Standard Specification forDry-Cast Segmental Retaining Wall Units1This standard is issued under the fixed designation C1372; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、 number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers dry-cast segmental retaining wall units of concrete, machinemade from hydraulic cement, water,and suitable
3、mineral aggregates with or without the inclusion of other materials. The units are intended for use in the constructionof mortarless segmental retaining walls.NOTE 1When particular features are desired, such as density classification, higher compressive strength, surface texture, finish, color, or o
4、ther specialfeatures, such properties should be specified separately by the purchaser. Suppliers should be consulted as to availability of units having the desiredfeatures.1.2 The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes(exclud
5、ing those in tables and figures) shall not be considered as requirements of the standard.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered sta
6、ndard.2. Referenced Documents2.1 ASTM Standards:2C33 Specification for Concrete AggregatesC140 Test Methods for Sampling and Testing Concrete Masonry Units and Related UnitsC150 Specification for Portland CementC331 Specification for Lightweight Aggregates for Concrete Masonry UnitsC595 Specificatio
7、n for Blended Hydraulic CementsC618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in ConcreteC989 Specification for Slag Cement for Use in Concrete and MortarsC1157 Performance Specification for Hydraulic CementC1232 Terminology of MasonryC1262 Test Method for Evaluatin
8、g the Freeze-Thaw Durability of Dry-Cast Segmental Retaining Wall Units and RelatedConcrete Units3. Terminology3.1 Terminology defined in Terminology C1232 shall apply for this specification.3.2 Definitions:3.2.1 Dry-cast, adjmanufacturing concrete products using low frequency, high amplitude vibrat
9、ion to consolidate concrete ofstiff or extremely dry consistency in a form.3.2.2 segmental retaining wall unit, nunit manufactured of concrete for the construction of dry-stacked earth retaining walls.3.2.3 segmental retaining wall unit, dry-cast, na segmental retaining wall unit manufactured of con
10、crete using a dry-castprocess.4. Materials4.1 Cementitious MaterialsMaterials shall conform to the following applicable specifications:4.1.1 Portland CementsSpecification C150.1 This specification is under the jurisdiction of ASTM Committee C15 on Manufactured Masonry Units and is the direct respons
11、ibility of C15.03 on Concrete MasonryUnits and Related UnitsCurrent edition approved Dec. 1, 2014June 1, 2016. Published January 2015July 2016. Originally approved in 1997. Last previous edition approved in 2014 asC1372 14.C1372 14a. DOI: 10.1520/C1372-14A.10.1520/C1372-16.2 For referencedASTM stand
12、ards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an AS
13、TM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published
14、 by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.1.2 Modified Portland CementPortland cement conforming to Specificat
15、ion C150, modified as follows:4.1.2.1 LimestoneLimestone, with a minimum 85 % Calcium Carbonate (CaCO3) content, shall be permitted to be added tothe cement, provided these requirements of Specification C150 as modified are met:(1) Limitation on Insoluble Residue1.5 %.(1) Limitation on Insoluble Res
16、idue1.5 %.(2) Limitation on Air Content of MortarVolume percent, 22 % max.(3) Limitation on Loss of Ignition7 %.(2) Limitation on Air Content of MortarVolume percent, 22 % max.(3) Limitation on Loss of Ignition7 %.4.1.3 Blended Hydraulic CementsSpecification C595.4.1.4 Hydraulic CementSpecification
17、C1157.4.1.5 PozzolansSpecification C618.4.1.6 Blast Furnace Slag CementSpecification C989.4.2 AggregatesAggregates shall conform to the following specifications, except that grading requirements shall notnecessarily apply:4.2.1 Normal Weight AggregatesSpecification C33.4.2.2 Lightweight AggregatesSp
18、ecification C331.4.3 Other ConstituentsAir-entraining agents, coloring pigments, integral water repellents, finely ground silica, and otherconstituents shall be previously established as suitable for use in segmental retaining wall units and shall conform to applicableASTM standards or shall be show
19、n by test or experience to be not detrimental to the durability of the segmental retaining wallunits or any material customarily used in segmental retaining wall construction.5. Physical Requirements5.1 At the time of delivery to the work site, the units shall conform to the physical requirements of
20、 Table 1 when tested inaccordance with 8.2. All units shall be sound and free of cracks or other defects that interfere with the proper placement of theunits or significantly impair the strength or permanence of the construction. Minor cracks incidental to the usual method ofmanufacture or minor chi
21、pping resulting from customary methods of handling in shipment and delivery are not grounds forrejection.5.1.1 When higher compressive strengths than those listed in Table 1 are specified, the tested average net area compressivestrength of three units shall equal or exceed the specified compressive
22、strength, and the following single unit strength requirementsshall apply.5.1.1.1 When the specified compressive strength is less than 5000 psi, no single unit net area compressive strength test resultshall be less than the specified compressive strength minus 500 psi.5.1.1.2 When the specified compr
23、essive strength is 5000 psi or greater, no single unit net area compressive strength test resultshall be less than 90 % of the specified compressive strength.5.2 Freeze-Thaw DurabilityIn areas where repeated freezing and thawing under saturated conditions occur, freeze-thawdurability shall be demons
24、trated by test or by proven field performance that the segmental retaining wall units have adequatedurability for the intended use. When testing is required by the specifier to demonstrate freeze-thaw durability, the units shall betested in accordance with 8.3.5.2.1 Specimens shall comply with eithe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC13722016STANDARDSPECIFICATIONFORDRYCASTSEGMENTALRETAININGWALLUNITS 拼装 挡土墙 部件 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-464392.html