1、Designation: C1372 14aStandard Specification forDry-Cast Segmental Retaining Wall Units1This standard is issued under the fixed designation C1372; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number
2、in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers dry-cast segmental retainingwall units of concrete, machinemade from hydraulic cement,water, and suitable mineral a
3、ggregates with or without theinclusion of other materials. The units are intended for use inthe construction of mortarless segmental retaining walls.NOTE 1When particular features are desired, such as densityclassification, higher compressive strength, surface texture, finish, color,or other special
4、 features, such properties should be specified separately bythe purchaser. Suppliers should be consulted as to availability of unitshaving the desired features.1.2 The text of this standard references notes and footnotesthat provide explanatory material. These notes and footnotes(excluding those in
5、tables and figures) shall not be consideredas requirements of the standard.1.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.2. Referen
6、ced Documents2.1 ASTM Standards:2C33 Specification for Concrete AggregatesC140 Test Methods for Sampling and Testing ConcreteMasonry Units and Related UnitsC150 Specification for Portland CementC331 Specification for Lightweight Aggregates for ConcreteMasonry UnitsC595 Specification for Blended Hydr
7、aulic CementsC618 Specification for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in ConcreteC989 Specification for Slag Cement for Use in Concrete andMortarsC1157 Performance Specification for Hydraulic CementC1232 Terminology of MasonryC1262 Test Method for Evaluating the Freeze-Thaw Du
8、ra-bility of Dry-Cast Segmental Retaining Wall Units andRelated Concrete Units3. Terminology3.1 Terminology defined in Terminology C1232 shall applyfor this specification.3.2 Definitions:3.2.1 Dry-cast, adjmanufacturing concrete products usinglow frequency, high amplitude vibration to consolidate co
9、n-crete of stiff or extremely dry consistency in a form.3.2.2 segmental retaining wall unit, nunit manufacturedof concrete for the construction of dry-stacked earth retainingwalls.3.2.3 segmental retaining wall unit, dry-cast, na segmen-tal retaining wall unit manufactured of concrete using adry-cas
10、t process.4. Materials4.1 Cementitious MaterialsMaterials shall conform to thefollowing applicable specifications:4.1.1 Portland CementsSpecification C150.4.1.2 Modified Portland CementPortland cement con-forming to Specification C150, modified as follows:4.1.2.1 LimestoneLimestone, with a minimum 8
11、5 % Cal-cium Carbonate (CaCO3) content, shall be permitted to beadded to the cement, provided these requirements of Specifi-cation C150 as modified are met:(1) Limitation on Insoluble Residue1.5 %.(2) Limitation on Air Content of MortarVolume percent,22 % max.(3) Limitation on Loss of Ignition7 %.4.
12、1.3 Blended Hydraulic CementsSpecification C595.4.1.4 Hydraulic CementSpecification C1157.4.1.5 PozzolansSpecification C618.4.1.6 Blast Furnace Slag CementSpecification C989.4.2 AggregatesAggregates shall conform to the followingspecifications, except that grading requirements shall notnecessarily a
13、pply:4.2.1 Normal Weight AggregatesSpecification C33.4.2.2 Lightweight AggregatesSpecification C331.1This specification is under the jurisdiction of ASTM Committee C15 onManufactured Masonry Units and is the direct responsibility of C15.03 on ConcreteMasonry Units and Related UnitsCurrent edition ap
14、proved Dec. 1, 2014. Published January 2015. Originallyapproved in 1997. Last previous edition approved in 2014 as C1372 14. DOI:10.1520/C1372-14A.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandard
15、s volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.3 Other ConstituentsAir-entrainin
16、g agents, coloringpigments, integral water repellents, finely ground silica, andother constituents shall be previously established as suitable foruse in segmental retaining wall units and shall conform toapplicable ASTM standards or shall be shown by test orexperience to be not detrimental to the du
17、rability of thesegmental retaining wall units or any material customarily usedin segmental retaining wall construction.5. Physical Requirements5.1 At the time of delivery to the work site, the units shallconform to the physical requirements of Table 1 when tested inaccordance with 8.2.All units shal
18、l be sound and free of cracksor other defects that interfere with the proper placement of theunits or significantly impair the strength or permanence of theconstruction. Minor cracks incidental to the usual method ofmanufacture or minor chipping resulting from customarymethods of handling in shipmen
19、t and delivery are not groundsfor rejection.5.1.1 When higher compressive strengths than those listedin Table 1 are specified, the tested average net area compres-sive strength of three units shall equal or exceed the specifiedcompressive strength, and the following single unit strengthrequirements
20、shall apply.5.1.1.1 When the specified compressive strength is less than5000 psi, no single unit net area compressive strength testresult shall be less than the specified compressive strengthminus 500 psi.5.1.1.2 When the specified compressive strength is 5000 psior greater, no single unit net area
21、compressive strength testresult shall be less than 90 % of the specified compressivestrength.5.2 Freeze-Thaw DurabilityIn areas where repeated freez-ing and thawing under saturated conditions occur, freeze-thawdurability shall be demonstrated by test or by proven fieldperformance that the segmental
22、retaining wall units haveadequate durability for the intended use. When testing isrequired by the specifier to demonstrate freeze-thaw durability,the units shall be tested in accordance with 8.3.5.2.1 Specimens shall comply with either of the following:(1) the weight loss of each of five test specim
23、ens at theconclusion of 100 cycles shall not exceed1%ofitsinitialweight; or (2) the weight loss of each of four of the five testspecimens at the conclusion of 150 cycles shall not exceed1.5 % of its initial weight.6. Permissible Variations in Dimensions6.1 Overall dimensions for width, height, and l
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC13722014ASTANDARDSPECIFICATIONFORDRYCASTSEGMENTALRETAININGWALLUNITS 拼装 挡土墙 部件 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-464391.html