《ASTM B971-2010 Standard Specification for Silver-Coated Braid and Ribbon Flat Copper Wire intended for use in Electronic Application《预用作电子设施的镀银织带和缎带扁铜线的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM B971-2010 Standard Specification for Silver-Coated Braid and Ribbon Flat Copper Wire intended for use in Electronic Application《预用作电子设施的镀银织带和缎带扁铜线的标准规范》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B971 10Standard Specification forSilver-Coated Braid and Ribbon Flat Copper Wire intendedfor use in Electronic Application1This standard is issued under the fixed designation B971; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers silver-coated copper braid andribbon flat wire intended for electroni
3、c application (Explana-tory Note 1).1.2 Two classes of silver-coated braid and ribbon flat copperwire are covered as follows:1.2.1 Class AAnnealed temper.1.2.2 Class HHard-drawn.1.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalc
4、onversions to SI units that are provided for information onlyand are not considered standard.1.3.1 ExceptionsThe SI values for density, resistivity, andvolume are to be regarded as standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It i
5、s theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2B1 Specification for Hard-Drawn Copper WireB3 Specification for Soft or Annealed C
6、opper WireB49 Specification for Copper Rod Drawing Stock for Elec-trical PurposesB193 Test Method for Resistivity of Electrical ConductorMaterialsB258 Specification for Nominal Diameters and Cross-Sectional Areas of AWG Sizes of Solid Round Wires Usedas Electrical Conductors2.2 Other Standards:3NBS
7、Handbook 100 Copper Wire Tables3. Ordering Information3.1 Orders for material under this specification shall includethe following information:3.1.1 Quantity of each size,3.1.2 Wire size-thickness and width in inches (see 5.4),3.1.3 Class of wire (see 1.2),3.1.4 Type of copper, if special (see 4.2),3
8、.1.5 Package size (see 10.1),3.1.6 Special packaging marking, if required, and3.1.7 Place of inspection (see 7.1).4. Material4.1 The material shall be silver-coated flat wire (Explana-tory Note 1) of such quality and purity that the finished productshall meet the properties and characteristics presc
9、ribed in thisspecification.4.2 Copper-Base MetalThe base metal shall be copper ofsuch quality and purity that the finished product shall haveproperties and characteristics prescribed in this specification.NOTE 1Specifications B1, B3,orB49 define copper suitable for use.5. General Requirements (See S
10、ection 8)5.1 TemperThe silver-coated flat wire conductor shall beprovided in either hard-drawn condition (Class H) or annealedcondition (Class A) as agreed upon between the manufacturerand purchaser.5.2 Tensile and Elongation (Explanatory Note 2):5.2.1 Class AThe silver-coated copper flat wire in th
11、eannealed condition shall conform to the elongation require-ments prescribed in Table 1. See Explanatory Note 3 forequivalent round diameter calculations based on given thick-ness and width dimensions for the flat wire. For flat wire whosenominal equivalent round diameter is more than 0.001 in.(0.02
12、5 mm) greater than a size listed in Table 1, but less thanthat of the next larger size, the requirements of the next largersize shall apply. No requirements for tensile strength arespecified.1This test method is under the jurisdiction of ASTM Committee B01 onElectrical Conductors and is the direct r
13、esponsibility of Subcommittee B01.04 onConductors of Copper and Copper Alloys.Current edition approved April 1, 2010. Published May 2010.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume i
14、nformation, refer to the standards Document Summary page onthe ASTM website.3Available from National Technical Information Service (NTIS), 5285 PortRoyal Rd., Springfield, VA 22161, http:/www.ntis.gov.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959
15、, United States.5.2.2 Class HThe silver-coated copper flat wire in thehard-drawn condition shall conform to elongation requirementsof 1% minimum to 5% maximum. The tensile strength shall be55,000 psi (379 MPa) minimum.5.3 Resistivity (Explanatory Note 4)The electrical resis-tivity of the coated wire
16、 at a temperature of 20C shall notexceed the values prescribed in Table 2.5.4 Dimensions and Permissible VariationsThe flat wiresizes shall be expressed as the thickness and width of the wirein decimal fractions of an inch to the nearest 0.0001 in. (0.0025mm). The silver-coated flat wire shall not v
17、ary from thespecified thickness and width by more than the amountsspecified in Table 3 and Table 4, respectively.5.5 Continuity of CoatingThe silver coating shall becontinuous. The continuity of coating on the flat wire shall bedetermined on representative samples taken before braidingapplications o
18、r insulating. The continuity of coating shall bedetermined by the hydrochloric acid-sodium polysulfide test inaccordance with 6.4. Wire whose coating weight correspondsto a thickness less than 40 in. (0.00004 in.) shall not besubject to this test (Explanatory Note 5). The thickness ofcoating shall b
19、e determined in accordance with Test Method Aas prescribed in Appendix X1.5.6 JointsNecessary joints in the wire and rods prior tofinal coating and drawing shall be made in accordance with thebest commercial practice. There shall be no uncoated joints inthe final product.5.7 FinishThe coating shall
20、consist of a smooth continu-ous layer, firmly adherent to the surface of the copper. The wireshall be free of all imperfections not consistent with the bestcommercial practice.6. Test Methods6.1 Tensile Strength and Elongation (Explanatory Note 6):6.1.1 The tensile strength, expressed in pounds per
21、squareinch, shall be obtained by dividing the maximum load carriedby the specimen during the tension test by the originalcross-sectional area of the specimen. Tensile strength andelongation may be determined simultaneously on the samespecimen.6.1.2 The elongation shall be determined as the permanent
22、increase in length, expressed in percent of the original length,due to the wire breaking in tension. The elongation of the flatwire may be determined by measurements made between thejaws of the tensile testing machine. The zero length shall be thedistance between the jaws at the start of the tension
23、 test and beas near 10 in. (254 mm) as practicable. The final length shall bethe distance between the jaws at the time of rupture. Thefracture shall be between the jaws of the testing machine andnot closer than 1 in. (25.4 mm) to the jaw.6.2 Resistivity (Explanatory Note 4)The electrical resis-tivit
24、y of the material shall be determined in accordance withTest Method B193. The purchaser may accept certification thatthe wire was drawn from rod stock meeting the internationalstandard for annealed copper instead of resistivity tests on thefinished wire.6.3 Dimensional MeasurementsDimensional measur
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB9712010STANDARDSPECIFICATIONFORSILVERCOATEDBRAIDANDRIBBONFLATCOPPERWIREINTENDEDFORUSEINELECTRONICAPPLICATION

链接地址:http://www.mydoc123.com/p-462964.html