NAVY UFGS-09 90 00-2011 PAINTS AND COATINGS《涂料和涂层》.pdf
《NAVY UFGS-09 90 00-2011 PAINTS AND COATINGS《涂料和涂层》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-09 90 00-2011 PAINTS AND COATINGS《涂料和涂层》.pdf(78页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-09 90 00 (May 2011)-Preparing Activity: NAVFAC SupersedingUFGS-09 90 00 (August 2010)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2011*SECTION TABLE OF CONTENTSDIVISION 09 - FINISHESSECTION 09 90 00PAINTS AND COATINGS05
2、/11PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 APPLICATORS QUALIFICATIONS1.3.1 Contractor Qualification1.3.2 SSPC QP 1 Certification1.4 QUALITY ASSURANCE1.4.1 Field Samples and Tests1.4.1.1 Sampling Procedure1.4.1.2 Testing Procedure1.4.2 Textured Wall Coating System1.4.3 Sample Textured Wall Coat
3、ing System Mock-Up1.4.4 Sustainable Design Certification1.5 REGULATORY REQUIREMENTS1.5.1 Environmental Protection1.5.2 Lead Content1.5.3 Chromate Content1.5.4 Asbestos Content1.5.5 Mercury Content1.5.6 Silica1.5.7 Human Carcinogens1.6 PACKAGING, LABELING, AND STORAGE1.7 SAFETY AND HEALTH1.7.1 Safety
4、 Methods Used During Coating Application1.7.2 Toxic Materials1.8 ENVIRONMENTAL CONDITIONS1.8.1 Coatings1.8.2 Post-Application1.9 SUSTAINABLE DESIGN REQUIREMENTS1.9.1 Local/Regional Materials1.9.2 Environmental Data1.10 SCHEDULING1.11 COLOR SELECTION1.12 LOCATION AND SURFACE TYPE TO BE PAINTED1.12.1
5、Painting IncludedSECTION 09 90 00 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1.12.1.1 Exterior Painting1.12.1.2 Interior Painting1.12.2 Painting Excluded1.12.3 Mechanical and Electrical Painting1.12.3.1 Fire Extinguishing Sprinkler Systems
6、1.12.4 Exterior Painting of Site Work Items1.12.5 MISCELLANEOUS PAINTING1.12.6 Definitions and Abbreviations1.12.6.1 Qualification Testing1.12.6.2 Batch Quality Conformance Testing1.12.6.3 Coating1.12.6.4 DFT or dft1.12.6.5 DSD1.12.6.6 EPP1.12.6.7 EXT1.12.6.8 INT1.12.6.9 micron / microns1.12.6.10 mi
7、l / mils1.12.6.11 mm1.12.6.12 MPI Gloss Levels1.12.6.13 MPI System Number1.12.6.14 Paint1.12.6.15 REX1.12.6.16 RINPART 2 PRODUCTS2.1 MATERIALSPART 3 EXECUTION3.1 PROTECTION OF AREAS AND SPACES NOT TO BE PAINTED3.2 REPUTTYING AND REGLAZING3.3 RESEALING OF EXISTING EXTERIOR JOINTS3.3.1 Surface Conditi
8、on3.3.2 Backstops3.3.3 Primer and Bond Breaker3.3.4 Ambient Temperature3.3.5 Exterior Sealant3.3.6 Cleaning3.4 SURFACE PREPARATION3.4.1 Additional Requirements for Preparation of Surfaces With Existing Coatings3.4.2 Existing Coated Surfaces with Minor Defects3.4.3 Removal of Existing Coatings3.4.4 S
9、ubstrate Repair3.5 PREPARATION OF METAL SURFACES3.5.1 Existing and New Ferrous Surfaces3.5.2 Final Ferrous Surface Condition:3.5.3 Galvanized Surfaces3.5.4 Non-Ferrous Metallic Surfaces3.5.5 Terne-Coated Metal Surfaces3.5.6 Existing Surfaces with a Bituminous or Mastic-Type Coating3.6 PREPARATION OF
10、 CONCRETE AND CEMENTITIOUS SURFACE3.6.1 Concrete and Masonry3.6.2 Gypsum Board, Plaster, and Stucco3.6.3 Existing Asbestos Cement Surfaces3.7 PREPARATION OF WOOD AND PLYWOOD SURFACES3.7.1 New , Existing Uncoated, and Existing Coated Plywood and SECTION 09 90 00 Page 2Provided by IHSNot for ResaleNo
11、reproduction or networking permitted without license from IHS-,-,-Wood Surfaces, Except Floors:3.7.2 Wood Floor Surfaces, Natural Finish3.7.3 Interior Wood Surfaces, Stain Finish3.7.4 Water Blasting of Existing Coated Wood Surfaces:3.8 APPLICATION3.8.1 Coating Application3.8.2 Mixing and Thinning of
12、 Paints3.8.3 Two-Component Systems3.8.4 Coating Systems3.9 COATING SYSTEMS FOR METAL3.10 COATING SYSTEMS FOR CONCRETE AND CEMENTITIOUS SUBSTRATES3.11 COATING SYSTEMS FOR WOOD AND PLYWOOD3.12 PIPING IDENTIFICATION3.13 INSPECTION AND ACCEPTANCE3.14 WASTE MANAGEMENT3.15 PAINT TABLES3.15.1 EXTERIOR PAIN
13、T TABLES3.15.2 INTERIOR PAINT TABLES- End of Section Table of Contents -SECTION 09 90 00 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-09 90 00 (May 2011)-Preparing Activity: NAVFAC SupersedingUFGS-09 90 0
14、0 (August 2010)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2011*SECTION 09 90 00PAINTS AND COATINGS05/11*NOTE: This guide specification covers the requirements for painting of new and existing, interior and exterior substrates, including masonry, concrete
15、, metal, wood and other miscellaneous materials.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, dele
16、ting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome
17、 and should be submitted as a Criteria Change Request (CCR).*NOTE: This Guide Specification is used in the preparation of project specifications for Department of Defense facilities: 1. Buildings;2. Related mechanical, electrical, and miscellaneous items; and3. Shore-to-ship utility connections.This
18、 guide specification WAS NOT prepared to address the requirements of routine maintenance painting although it could be modified to do so.This guide specification DOES NOT address SECTION 09 90 00 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-
19、high-performance or specialty coating requirements, or protective coating of industrial structures or facilities, including but not limited to:1. Towers;2. Pilings;3. Pavement markings;4. Items requiring specialized treatment due to peculiar usage;5. Petroleum storage facilities;6. Water storage fac
20、ilities;7. Waterfront facilities, except shore-to-ship utility connections; and 8. HangarsIf such items are in the project they should be included in a separate section or this section should be modified accordingly. The following guide specifications are examples of those available for specific ser
21、vice conditions noted, and may be modified to provide for related service conditions:1. Section 09 97 23 METALLIC TYPE CONDUCTIVE/SPARK RESISTANT CONCRETE FLOOR FINISH. This specification covers the painting of hydraulic structures located in fresh water such as locks and dams.2. Section 09 97 13.15
22、 EPOXY/FLUOROPOLYURETHANE INTERIOR COATING OF WELDED STEEL PETROLEUM FUEL TANKS3. Section 09 97 13.27 EXTERIOR COATING OF STEEL STRUCTURES. This specification is usable for any steel structure exposed to weather, and is usable for other purposes as well, such as hangar structures, enclosed swimming
23、pool structures, and most situations requiring high-performance protective coating systems.4. Section 09 97 13.16 INTERIOR COATING OF WELDED STEEL WATER TANKS5. Section 09 97 13.15 EPOXY/FLUOROPOLYURETHANE INTERIOR COATING OF WELDED STEEL PETROLEUM FUEL TANKS. This is a three-coat epoxy system that
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS0990002011PAINTSANDCOATINGS 涂料 涂层 PDF

链接地址:http://www.mydoc123.com/p-984762.html