EN 60086-3-2016 en Primary batteries - Part 3 Watch batteries.pdf
《EN 60086-3-2016 en Primary batteries - Part 3 Watch batteries.pdf》由会员分享,可在线阅读,更多相关《EN 60086-3-2016 en Primary batteries - Part 3 Watch batteries.pdf(32页珍藏版)》请在麦多课文档分享上搜索。
1、Primary batteriesPart 3: Watch batteriesBS EN 60086-3:2016BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06National forewordThis British Standard is the UK implementation of EN 60086-3:2016. It isidentical to IEC 60086-3:2016. It supersedes BS EN 60086-3:2011 which wi
2、llbe withdrawn 29 June 2019.The UK participation in its preparation was entrusted to TechnicalCommittee CPL/35, Primary cells.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa
3、 contract. Users are responsible for its correct application. The British Standards Institution 2016.Published by BSI Standards Limited 2016ISBN 978 0 580 90795 1ICS 29.220.10; 39.040.10Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was publishe
4、d under the authority of theStandards Policy and Strategy Committee on 31 December 2016.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 60086-3:2016EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 60086-3 September 2016 ICS 29.220.10; 39.040.10 Supersedes EN
5、 60086-3:2011 English Version Primary batteries - Part 3: Watch batteries (IEC 60086-3:2016) Piles lectriques - Partie 3 : Piles pour montres (IEC 60086-3:2016) Primrbatterien - Teil 3: Uhrenbatterien (IEC 60086-3:2016) This European Standard was approved by CENELEC on 2016-06-29. CENELEC members ar
6、e bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to
7、the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Manag
8、ement Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ire
9、land, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Ko
10、mitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 60086-3:2016 E BS EN 60086-3:2016EN 60086-3:2016 2 European foreword The text o
11、f document 35/1359/FDIS, future edition 4 of IEC 60086-3, prepared by IEC/TC 35 “Primary cells and batteries“ and by ISO/TC 114 “Horology“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60086-3:2016. The following dates are fixed: latest date by which the document has t
12、o be implemented at national level by publication of an identical national standard or by endorsement (dop) 2017-03-29 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2019-06-29 This document supersedes EN 60086-3:2011. Attention is drawn to the p
13、ossibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 60086-3:2016 was approved by CENELEC as a European
14、Standard without any modification. In the official version, for Bibliography, the following note has to be added for the standard indicated : IEC 60068-2-78:2001 NOTE Harmonized as EN 60068-2-78:2001 (not modified). BS EN 60086-3:2016EN 60086-3:2016 3 Annex ZA (normative) Normative references to int
15、ernational publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition
16、 of the referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is a
17、vailable here: www.cenelec.eu. Publication Year Title EN/HD Year IEC 60086-1 2015 Primary batteries - Part 1: General EN 60086-1 2015 IEC 60086-2 2015 Primary batteries - Part 2: Physical and electrical specifications EN 60086-2 2016 IEC 60086-4 2014 Primary batteries - Part 4: Safety of lithium bat
18、teries EN 60086-4 2015 IEC 60086-5 2016 Primary batteries - Part 5: Safety of batteries with aqueous electrolyte EN 60086-5 1)1) To be published. BS EN 60086-3:2016 2 IEC 60086-3:2016 IEC 2016 CONTENTS FOREWORD . 4 INTRODUCTION . 6 1 Scope 7 2 Normative references. 7 3 Terms and definitions 7 4 Phys
19、ical requirements 8 4.1 Battery dimensions, symbols and size codes . 8 4.2 Terminals 10 4.3 Projection of the negative terminal (h5) 10 4.4 Shape of negative terminal 10 4.5 Mechanical resistance to pressure . 11 4.6 Deformation 11 4.7 Leakage 11 4.8 Marking . 12 4.8.1 General . 12 4.8.2 Disposal 12
20、 5 Electrical requirements 12 5.1 Electrochemical system, nominal voltage, end-point voltage and open-circuit voltage 12 5.2 Closed circuit voltage Ucc(CCV), internal resistance and impedance . 13 5.3 Capacity . 13 5.4 Capacity retention . 13 6 Sampling and quality assurance . 13 7 Test methods . 13
21、 7.1 Shape and dimensions 13 7.1.1 Shape requirement . 13 7.2 Electrical characteristics 14 7.2.1 Environmental conditions . 14 7.2.2 Equivalent circuit effective internal resistance DC method . 14 7.2.3 Equipment . 15 7.2.4 Measurement of open-circuit voltage Uoc(OCV) and closed circuit voltage Ucc
22、 (CCV) . 15 7.2.5 Calculation of the internal resistance Ri16 7.2.6 Measurement of the capacity 16 7.2.7 Calculation of the internal resistance Riduring discharge in case of method A (optional) 18 7.3 Test methods for determining the resistance to leakage . 20 7.3.1 Preconditioning and initial visua
23、l examination . 20 7.3.2 High temperature and humidity test 20 7.3.3 Test by temperature cycles 20 8 Visual examination and acceptance conditions . 21 8.1 Preconditioning . 21 8.2 Magnification 21 8.3 Lighting . 21 8.4 Leakage levels and classification . 21 8.5 Acceptance conditions. 23 BS EN 60086-
24、3:2016IEC 60086-3:2016 IEC 2016 3 Annex A (normative) Designation . 24 Bibliography . 25 Figure 1 Dimensional drawing 8 Figure 2 Shape of negative terminal . 11 Figure 3 Shape requirement . 14 Figure 4 Schematic voltage transient 14 Figure 5 Curve: U = f(t) 15 Figure 6 Circuitry principle . 16 Figur
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN6008632016ENPRIMARYBATTERIESPART3WATCHBATTERIESPDF

链接地址:http://www.mydoc123.com/p-717595.html