1、Designation: B174 10 (Reapproved 2015)B174 17Standard Specification forBunch-Stranded Copper Conductors for ElectricalConductors1This standard is issued under the fixed designation B174; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisi
2、on, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This specificati
3、on covers bare bunch-stranded conductors made from round copper wires, either uncoated or coated with tin,lead, or lead-alloy for use as electrical conductors (Explanatory Note 1 and Explanatory Note 2).1.2 Coated wires shall include only those wires with finished diameters and densities substantial
4、ly equal to the respectivediameters and densities of uncoated wires.1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in eachsystem may not be exact equivalents; therefore, each system shall be used independently of the other. C
5、ombining values from thetwo systems may result in non-conformance with the standard.1.3.1 For conductor sizes designated by AWG or kcmil, the requirements in SI units have been numerically converted fromcorresponding values, stated or derived, in inch-pound units. For conductor sizes designated by S
6、I units only, the requirements arestated or derived in SI units.1.4 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendation
7、s issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 The following documents of the issue in effect at the time of reference form a part of this specification to the extentreferenced herein:2.2 ASTM Standards:2B3 Specification for Soft or Ann
8、ealed Copper WireB33 Specification for Tin-Coated Soft or Annealed Copper Wire for Electrical PurposesB172 Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical ConductorsB189 Specification for Lead-Coated and Lead-Alloy-Coated Soft Copper Wire for Elect
9、rical PurposesB193 Test Method for Resistivity of Electrical Conductor MaterialsB263 Test Method for Determination of Cross-Sectional Area of Stranded ConductorsB354 Terminology Relating to Uninsulated Metallic Electrical Conductors2.3 American National Standard:ANSI C42.35 Definitions of Electrical
10、 Terms33. Classification3.1 For the purpose of this specification bunch-stranded conductors are classified as shown in Tables 1 and 2.1 This specification is under the jurisdiction of ASTM Committee B01 on Electrical Conductors and is the direct responsibility of Subcommittee B01.04 on Conductorsof
11、Copper and Copper Alloys.Current edition approved April 1, 2015April 1, 2017. Published April 2015April 2017. Originally approved in 1941. Last previous edition approved in 20102015 as B174 10. 10 (2015). DOI: 10.1520/B0174-10R15.10.1520/B0174-17.2 For referencedASTM standards, visit theASTM website
12、, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http
13、:/www.ansi.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users co
14、nsult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1TABLE 1 A Classification and Cons
15、truction Requirements of Bunch-Stranded ConductorsA Class I Bunch Stranded ConductorsArea ofCross SectionClassification,Size,andMinimumNumberof WiresUncoated Copper Coated CopperSize,AWGClass INominalWireDiameter0.0201 In.(0.511 mm)Nominal dcresistance20CMaximum dcresistance20CNominal dcresistance20
16、CMaximum dcresistance20CNominal dcresistance20CMaximum dcresistance20CNominal dcresistance20CMaximum dcresistance20Ccmil mm 24 AWG ohm/kft ohm/kft ohm/km ohm/km ohm/kft ohm/kft ohm/km ohm/km20820 10.5 7 52 0.508 0.518 1.67 1.70 0.528 0.539 1.73 1.7716510 8.37 8 41 0.641 0.654 2.10 2.14 0.666 0.679 2
17、.19 2.2313090 6.63 9 33 0.808 0.824 2.65 2.70 0.840 0.857 2.76 2.8110380 5.26 10 26 1.02 1.04 3.34 3.41 1.06 1.08 3.48 3.55TABLE 1 B Classification and Construction Requirements of Bunch-Stranded ConductorsClass J Bunch Stranded ConductorsAArea ofCross SectionClassification,Size,andMinimumNumberof W
18、iresUncoated Copper Coated CopperSize,AWGClass JNominalWireDiameter0.0126 In.(0.320 mm)Nominaldcresistance20CMaximumdcresistance20CNominaldcresistance20CMaximumdcresistance20CNominaldcresistance20CMaximumdcresistance20CNominaldcresistance20CMaximumdcresistance20Ccmil mm 28 AWG ohm/kft ohm/kft ohm/km
19、 ohm/km ohm/kft ohm/kft ohm/km ohm/km10380 5.26 10 65 1.02 1.04 3.34 3.41 1.08 1.10 3.54 3.616530 3.31 12 41 1.62 1.65 5.31 5.42 1.72 1.75 5.64 5.764110 2.08 14 26 2.57 2.62 8.44 8.61 2.73 2.79 8.96 9.142580 1.31 16 16 4.10 4.18 13.5 13.7 4.35 4.44 14.3 14.61620 0.821 18 10 6.53 6.66 21.4 21.9 6.94
20、7.07 22.8 23.21020 0.517 20 7 10.4 10.6 34.0 34.7 11.0 11.2 36.1 36.8TABLE 1 C Classification and Construction Requirements of Bunch-Stranded ConductorsClass K Bunch Stranded ConductorsAArea ofCross SectionClassification,Size,andMinimumNumberof WiresUncoated Copper Coated CopperArea ofCross SectionC
21、lassification,Size,andinimumNumberof WiresUncoated Copper Coated CopperSize,AWGClass KNominalWireDiameter0.0100 In.(0.254 mm)Nominaldcresistance20CMaximumdcresistance20CNominaldcresistance20CMaximumdcresistance20CNominaldcresistance20CMaximumdcresistance20CNominaldcresistance20CMaximumdcresistance20
22、Ccmil mm 30 AWG ohm/kft ohm/kft ohm/km ohm/km ohm/kft ohm/kft ohm/km ohm/km10380 5.26 10 104 1.02 1.04 3.35 3.41 1.09 1.12 3.58 3.656530 3.31 12 65 1.62 1.65 5.31 5.42 1.74 1.77 5.71 5.824110 2.08 14 41 2.57 2.62 8.43 8.60 2.76 2.82 9.06 9.242580 1.31 16 26 4.10 4.18 13.5 13.7 4.40 4.49 14.4 14.7162
23、0 0.821 18 16 6.53 6.66 21.4 21.9 7.01 7.15 23.0 23.51020 0.517 20 10B 10.4 10.6 34.1 34.8 11.1 11.4 36.4 37.1640 0.324 22 7 16.5 16.9 54.1 55.2 17.7 18.1 58.1 59.2A The constructions shown in these tables are typical of those used in the industry. It is intended that these tables preclude other con
24、structions which may be desirablefor specific applications. The constructions shown provide for a finished stranded conductor approximately of the area indicated. When specified by the purchaser, thenumber or sizes of wire may be increased to provide additional area to compensate for draw-down durin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB1742017STANDARDSPECIFICATIONFORBUNCHSTRANDEDCOPPERCONDUCTORSFORELECTRICALCONDUCTORS 导线 用成束绞捻铜 标准

链接地址:http://www.mydoc123.com/p-460533.html