ASTM B174-2010(2015) Standard Specification for Bunch-Stranded Copper Conductors for Electrical Conductors《电导线用成束绞捻铜导线的标准规格》.pdf
《ASTM B174-2010(2015) Standard Specification for Bunch-Stranded Copper Conductors for Electrical Conductors《电导线用成束绞捻铜导线的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM B174-2010(2015) Standard Specification for Bunch-Stranded Copper Conductors for Electrical Conductors《电导线用成束绞捻铜导线的标准规格》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B174 10 (Reapproved 2015)Standard Specification forBunch-Stranded Copper Conductors for ElectricalConductors1This standard is issued under the fixed designation B174; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This specification cove
3、rs bare bunch-stranded conduc-tors made from round copper wires, either uncoated or coatedwith tin, lead, or lead-alloy for use as electrical conductors(Explanatory Note 1 and Explanatory Note 2).1.2 Coated wires shall include only those wires with fin-ished diameters and densities substantially equ
4、al to the respec-tive diameters and densities of uncoated wires.1.3 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combini
5、ngvalues from the two systems may result in non-conformancewith the standard.1.3.1 For conductor sizes designated by AWG or kcmil, therequirements in SI units have been numerically converted fromcorresponding values, stated or derived, in inch-pound units.For conductor sizes designated by SI units o
6、nly, the require-ments are stated or derived in SI units.2. Referenced Documents2.1 The following documents of the issue in effect at thetime of reference form a part of this specification to the extentreferenced herein:2.2 ASTM Standards:2B3 Specification for Soft or Annealed Copper WireB33 Specifi
7、cation for Tin-Coated Soft or Annealed CopperWire for Electrical PurposesB172 Specification for Rope-Lay-Stranded Copper Conduc-tors Having Bunch-Stranded Members, for Electrical Con-ductorsB189 Specification for Lead-Coated and Lead-Alloy-CoatedSoft Copper Wire for Electrical PurposesB193 Test Meth
8、od for Resistivity of Electrical ConductorMaterialsB263 Test Method for Determination of Cross-SectionalArea of Stranded ConductorsB354 Terminology Relating to Uninsulated Metallic Electri-cal Conductors2.3 American National Standard:ANSI C42.35 Definitions of Electrical Terms33. Classification3.1 F
9、or the purpose of this specification bunch-strandedconductors are classified as shown in Tables 1 and 2.4. Ordering Information4.1 Orders for material under this specification shall includethe following information:4.1.1 Quantity of each size and class,4.1.2 Conductor size: circular-mil area or AWG
10、(see 7.1),4.1.3 Class (Section 3 and Table 3),4.1.4 Whether coated or uncoated; if coated, designate typeof coating (see 11.1),4.1.5 Maximum length of lay (see 6.3),4.1.6 Whether separator is required (see 7.2),4.1.7 Package size (see section 14.1),4.1.8 Special package marking, if required (Section
11、 14), and4.1.9 Place of inspection (Section 13).5. Joints5.1 Necessary joints in wires shall be made in accordancewith accepted commercial practice.5.2 Joints shall be so constructed and so disposed through-out the conductor that the diameter or configuration of thecompleted conductor is not substan
12、tially affected, and so thatthe flexibility of the completed conductor is not adverselyaffected.1This specification is under the jurisdiction of ASTM Committee B01 onElectrical Conductors and is the direct responsibility of Subcommittee B01.04 onConductors of Copper and Copper Alloys.Current edition
13、 approved April 1, 2015. Published April 2015. Originallyapproved in 1941. Last previous edition approved in 2010 as B174 10. DOI:10.1520/B0174-10R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStand
14、ards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken,
15、 PA 19428-2959. United States16. Lay6.1 Conductors of the same size and description furnishedon one order shall have the same lay.6.2 The direction of lay shall be at the option of themanufacturer unless otherwise specified.TABLE 1 A Classification and Construction Requirements of Bunch-Stranded Con
16、ductorsAClass I Bunch Stranded ConductorsArea ofCross SectionClassification,Size,andMinimumNumberof WiresUncoated Copper Coated CopperSize,AWGClass INominalWireDiameter0.0201 In.(0.511 mm)Nominal dcresistance20CMaximum dcresistance20CNominal dcresistance20CMaximum dcresistance20CNominal dcresistance
17、20CMaximum dcresistance20CNominal dcresistance20CMaximum dcresistance20Ccmil mm 24 AWG ohm/kft ohm/kft ohm/km ohm/km ohm/kft ohm/kft ohm/km ohm/km20820 10.5 7 52 0.508 0.518 1.67 1.70 0.528 0.539 1.73 1.7716510 8.37 8 41 0.641 0.654 2.10 2.14 0.666 0.679 2.19 2.2313090 6.63 9 33 0.808 0.824 2.65 2.7
18、0 0.840 0.857 2.76 2.8110380 5.26 10 26 1.02 1.04 3.34 3.41 1.06 1.08 3.48 3.55TABLE1BClassification and Construction Requirements of Bunch-Stranded ConductorsClass J Bunch Stranded ConductorsAArea ofCross SectionClassification,Size,andMinimumNumberof WiresUncoated Copper Coated CopperSize,AWGClass
19、JNominalWireDiameter0.0126 In.(0.320 mm)Nominaldcresistance20CMaximumdcresistance20CNominaldcresistance20CMaximumdcresistance20CNominaldcresistance20CMaximumdcresistance20CNominaldcresistance20CMaximumdcresistance20Ccmil mm 28 AWG ohm/kft ohm/kft ohm/km ohm/km ohm/kft ohm/kft ohm/km ohm/km10380 5.26
20、 10 65 1.02 1.04 3.34 3.41 1.08 1.10 3.54 3.616530 3.31 12 41 1.62 1.65 5.31 5.42 1.72 1.75 5.64 5.764110 2.08 14 26 2.57 2.62 8.44 8.61 2.73 2.79 8.96 9.142580 1.31 16 16 4.10 4.18 13.5 13.7 4.35 4.44 14.3 14.61620 0.821 18 10 6.53 6.66 21.4 21.9 6.94 7.07 22.8 23.21020 0.517 20 7 10.4 10.6 34.0 34
21、.7 11.0 11.2 36.1 36.8TABLE1CClassification and Construction Requirements of Bunch-Stranded ConductorsClass K Bunch Stranded ConductorsAArea ofCross SectionClassification,Size,andMinimumNumberof WiresUncoated Copper Coated CopperSize,AWGClass KNominalWireDiameter0.0100 In.(0.254 mm)Nominaldcresistan
22、ce20CMaximumdcresistance20CNominaldcresistance20CMaximumdcresistance20CNominaldcresistance20CMaximumdcresistance20CNominaldcresistance20CMaximumdcresistance20Ccmil mm 30 AWG ohm/kft ohm/kft ohm/km ohm/km ohm/kft ohm/kft ohm/km ohm/km10380 5.26 10 104 1.02 1.04 3.35 3.41 1.09 1.12 3.58 3.656530 3.31
23、12 65 1.62 1.65 5.31 5.42 1.74 1.77 5.71 5.824110 2.08 14 41 2.57 2.62 8.43 8.60 2.76 2.82 9.06 9.242580 1.31 16 26 4.10 4.18 13.5 13.7 4.40 4.49 14.4 14.71620 0.821 18 16 6.53 6.66 21.4 21.9 7.01 7.15 23.0 23.51020 0.517 20 10B10.4 10.6 34.1 34.8 11.1 11.4 36.4 37.1640 0.324 22 7 16.5 16.9 54.1 55.
24、2 17.7 18.1 58.1 59.2AThe constructions shown in these tables are typical of those used in the industry. It is intended that these tables preclude other constructions which may be desirablefor specific applications. The constructions shown provide for a finished stranded conductor approximately of t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB17420102015STANDARDSPECIFICATIONFORBUNCHSTRANDEDCOPPERCONDUCTORSFORELECTRICALCONDUCTORS 导线 用成束绞捻铜

链接地址:http://www.mydoc123.com/p-460532.html