ASTM D7459-2008(2016) 2797 Standard Practice for Collection of Integrated Samples for the Speciation of Biomass (Biogenic) and Fossil-Derived Carbon Dioxide Emitted from Stationary.pdf
《ASTM D7459-2008(2016) 2797 Standard Practice for Collection of Integrated Samples for the Speciation of Biomass (Biogenic) and Fossil-Derived Carbon Dioxide Emitted from Stationary.pdf》由会员分享,可在线阅读,更多相关《ASTM D7459-2008(2016) 2797 Standard Practice for Collection of Integrated Samples for the Speciation of Biomass (Biogenic) and Fossil-Derived Carbon Dioxide Emitted from Stationary.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7459 08 (Reapproved 2016)Standard Practice forCollection of Integrated Samples for the Speciation ofBiomass (Biogenic) and Fossil-Derived Carbon DioxideEmitted from Stationary Emissions Sources1This standard is issued under the fixed designation D7459; the number immediately following
2、the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice defines
3、specific procedures for the collec-tion of gas samples from stationary emission sources forsubsequent laboratory determination of the ratio of biomass(biogenic) carbon to total carbon (fossil derived carbon plusbiomass or biogenic carbon) in accordance with Test MethodsD6866.1.2 This practice applie
4、s to stationary sources that burnmunicipal solid waste or a combination of fossil fuel (forexample, coal, oil, natural gas) and biomass fuel (for example,wood, wood waste, paper, agricultural waste, biogas) inboilers, combustion turbines, incinerators, kilns, internal com-bustion engines and other c
5、ombustion devices.1.3 This practice applies to the collection of integratedsamples over periods from 1 hour to 24 hours, or longer.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.5 This standard does not purport to address
6、 all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1356 Terminology
7、 Relating to Sampling and Analysis ofAtmospheresD4840 Guide for Sample Chain-of-Custody ProceduresD6866 Test Methods for Determining the Biobased Contentof Solid, Liquid, and Gaseous Samples Using Radiocar-bon Analysis2.2 Federal Standards:340 CFR 60 Appendix B, Performance Specification40 CFR 60 Ap
8、pendix A, Reference MethodUncertainties In Non-Proportional Sampling Part 75 PolicyAnd Communication Efforts, EPAContract No. EP-W-07-064, Work Assignment No. 0-8, Task No. 6 (February 15,2008 Draft)3. Terminology3.1 DefinitionsFor additional definitions of terms used inthis practice, refer to Termi
9、nology D1356 and Test MethodsD6866.3.2 Definitions of Terms Specific to This Standard:3.2.1 biomass (biogenic) CO2,nCO2recently removedfrom the atmosphere by plants, then returned to the atmosphereby combustion or biogenic decay.3.2.1.1 DiscussionBiomass CO2emitted from combustiondevices is often re
10、ferred to as “carbon-neutral CO2.”3.2.1.2 DiscussionBiomass carbon contains the isotoperadiocarbon (carbon-14) in measurable quantities. Radiocarbonis a radioactive isotope of the element carbon, carbon-14,having 8 neutrons, 6 protons, and 6 electrons making up 1 10-12natural abundance of carbon on
11、earth. It decays exponen-tially with a half-life of about 5700 years and as such is notmeasurable in fossil materials derived from petroleum, coal,natural gas, or any other source more than about 50 000 yearsold.3.2.2 constant rate sampling, nsampling conducted at afixed sampling rate.3.2.3 Fossil C
12、O2,nCO2introduced into the atmospherethrough the combustion or thermal dissociation of fossilmaterials.3.2.3.1 DiscussionFossil-derived CO2is void of radiocar-bon and consists entirely of the “stable carbon” isotopes1This practice is under the jurisdiction ofASTM Committee D22 on Air Qualityand is t
13、he direct responsibility of Subcommittee D22.03 on Ambient Atmospheresand Source Emissions.Current edition approved March 1, 2016. Published March 2016. Originallyapproved in 2008. Last previous edition approved in 2008 as D7459 08. DOI:10.1520/D7459-08R16.2For referenced ASTM standards, visit the A
14、STM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Standardization Documents Order Desk, DODSSP, Bldg. 4,Section D, 700 Robbins Ave., Phila
15、delphia, PA 19111-5098, http:/www.dodssp.daps.mil.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1carbon-13 (having 7 neutrons, 6 protons, and 6 electrons)making up 1.2 % natural abundance carbon on earth andcarbon-12 (having 6 neutro
16、ns, 6 protons, and 6 electrons) andmaking up 98.8 % natural abundance carbon on earth.3.2.4 proportional sampling, nsampling conducted suchthat the ratio of the sampling rate to stack gas velocity orvolumetric flow rate is constant.3.2.5 speciation, nidentification of the biomass and fossil-derived
17、CO2components within bulk air effluents.3.2.6 sub-sampling, nthe process of taking a representa-tive smaller amount of sample volume from a large bulksample volume.4. Summary of Practice4.1 Representative gas samples are collected at a constantrate from stationary emission sources into portable cont
18、ainersfor shipment to off-site analytical facilities performing TestMethods D6866 analysis.NOTE 1The complexity of the analytical method requires analysis tobe performed off-site.4.2 If the variability of stack gas velocity or CO2concentration, or both, is beyond specified limits, proportionalrate s
19、ampling may need to be used. See Section 8.NOTE 2The majority of combustion sources are such that theiroperational conditions do not vary significantly and, hence, constant ratesampling would provide representative samples. However, there are somesources, for example, peaking units, whose effluent f
20、low rate (velocity)and CO2concentrations vary considerably. In such cases, it is necessary tosample proportionally. Guidelines are given on when proportional sam-pling is necessary.5. Significance and Use5.1 Greenhouse gases are reported to be a major contributorto global warming. Since “biomass CO2
21、” emitted from com-bustion devices represents a net-zero carbon contribution to theatmosphere (that is, plants remove CO2from the atmosphereand subsequent combustion returns it), it does not contributeadditional CO2to the atmosphere. The measurement of bio-mass (biogenic) CO2allows regulators and st
22、ationary sourceowners/operators to determine the ratio of fossil-derived CO2and biomass CO2in developing control strategies and to meetfederal, state, local and regional greenhouse gas reportingrequirements.5.2 The distinction of the two types of CO2has financial,control and regulatory implications.
23、6. Apparatus6.1 ProbeTubing of sufficient length, equipped with anin-stack or out-stack filter to remove particulate matter. Theprobe may be made of any material that is inert to CO2andresistant to temperature at sampling conditions, for example,stainless steel, borosilicate glass, quartz, or polyte
24、trafluoroeth-ylene.The filter may be a plug of glass wool. Samples may alsobe taken at the exhaust of any extractive continuous emissionmonitoring system (CEMS) used for monitoring pollutant ordiluent concentrations, including both full extractive and dilu-tion sampling systems.NOTE 3Samples may be
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7459200820162797STANDARDPRACTICEFORCOLLECTIONOFINTEGRATEDSAMPLESFORTHESPECIATIONOFBIOMASSBIOGENICANDFOSSILDERIVEDCARBONDIOXIDEEMITTEDFROMSTATIONARYPDF

链接地址:http://www.mydoc123.com/p-525542.html