《EN ISO 3822-4-1997 en Acoustics - Laboratory Tests on Noise Emission from Appliances and Equipment Used in Water Supply Installations - Part 4 Mounting and Operating Conditions for.pdf》由会员分享,可在线阅读,更多相关《EN ISO 3822-4-1997 en Acoustics - Laboratory Tests on Noise Emission from Appliances and Equipment Used in Water Supply Installations - Part 4 Mounting and Operating Conditions for.pdf(32页珍藏版)》请在麦多课文档分享上搜索。
1、STD-BSI BS EN IS0 3822-q-ENGL 1777 Lb24bbl Ob337bB T23 W BRITISH STANDARD Acoustics - Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 4. Mounting and operating conditions for special appliances The European Standard EN IS0 38224 : 1997 has the
2、 status of a British Standard BS EN IS0 3822-4 : 1997 ICs 17.140.20, 91.140.60 zzggii i 5El!j AGG 3.4.3.2; 3.4.3.3; 3.4.3.4 shall be camed out at flow pressures of 0,3 MPa and 0,5 MPa. Additional tests are necessary in some cases when flow adjusters are incorporated into the appliance. Stop valves i
3、ncorporated into the appliance shall be fully open unless they are intended to be used as flow adjusters. Float operated valves used in cistern type water heaters shall be tested in accordance with 3.2. 3.4.3.2 Storage water heaters of the closed type a) If the water heater incorporates an integral
4、draw-off tap or mixing valve, it shall be tested in accordance with EN IS0 3822-2, including requirements for flow adjusters. b) Water heaters without an integrd draw-off tap or mixing valve, but incorporating some device which influences the flow rate or pressure of the water, such as a flow adjust
5、er, shall be tested with an adjustable low-noise flow resistance (see example given in EN IS0 3822-3) connected to the outlet. The adjustable lownoise flow resistance shall be set so that at a flow pressure of 0,s g in th extreme cold position. If the mixing valve incorporates a flow adjuster in the
6、 cold inlet, it shall be left as supplied. 3.5.2.2The hot water side shall be tested in accordance with clauses 4.1, (excluding 4.1 S), and 4.2 of EN IS0 3822-2, with the temperature setting in the extreme hot position. When testing the hot water side the flow adjuster shall be set at a flow pressur
7、e of 0,3 MPa with the mixing valve flow control fully open in the hot position so that the maximum flow rate, expressed in litres per second, through the hot side of the valve is equal to IA20 of the nominal heating power, expressed in kilowatts, of the heater with which the mixing valve is expected
8、 to be used. where the mixing valve is to be used with heaters of various heating powers the tests shall be carried out with the flow adjuster set according to both the maximum and minimum nominal heating power. Flow adjusters with a fixed setting or automatic function shall be left as supplied. Bef
9、ore repeating the test at a flow pressure of 0,5 MPa the flow adjuster shall be set at a flow pressure of 0,3 MPa to the flow rate specified above. Then increase the flow pressure to 0,5 MPa. 3.6 Mixing valves for overflow (open outlet) type water heaters 3.6.1 Mixing valves for overflow (open outle
10、t) type storage water heaters 3.6.1.1 Mounting conditions Mixing valves for overflow (open ouet) type storage water heaters shall have their inlet connected directly to the test pipe (see 3.1). In place of the heater tank or vessel, a by-pass shall be used. This by-pass shall be constructed of any s
11、uitable material and in such a way that additional noise production is unlikely and with the least practicable influence on flow rate. The bore of the by-pass tube throughout its length shall be not less than the nominal bore of the connections for the heater. 6 STD-BSI BS EN IS0 3822-q-ENGL 1777 Ib
12、Z4bb9 Ob33781 4b7 EN IS0 3822-4 : 1997 3.6.1.2 Operating conditions Generally the mixing valve shall be tested in accordance with clauses 4.1, (excluding 4.1 .3), and 4.3 of EN IS0 3822-2. Mixing valves having a blending device for temperature adjustment downstream of the flow control shall be teste
13、d in accordance with clause 4.2 of EN IS0 3822-2, with the temperature adjustment device in the cold position. Then operate the temperature adjustment device over its full range of adjustment, with the flow control fully open, to determine the maximum sound pressure level. Mixing valves with more th
14、an one outlet (for example bath and shower mixing valves) shall be tested separately for each outlet. If the mixing valve is supplied with a removable outlet accessory such as a shower hose, shower head, flow straightener etc., the test shall be carried out with this in place. Otherwise nothing shal
15、l be connected to the mixing valve outlet during the test. 3.6.2 Mixing valves for overflow (open outlet) type instantaneous water heaters 3.6.2.1 Mounting conditions Mixing valves for overflow (open outlet) type instantaneous water heaters shall be mounted according to 3.6.1.1. 3.6.2.2 Operating co
16、nditions The mixing valve shall be tested in accordance with clauses 4.1, (excluding 4.1.3, 4.1 S), and 4.3 of EN IS0 3822-2. Mixing valves having a blending device for temperature adjustment downstream of the flow control shall be tested in accordance with clause 4.2 of EN IS0 3822-2, with the temp
17、erature adjustment device in the cold position. Then operate the temperature adjustment device over its full range of adjustment, with the flow control fully open, to determine the maximum sound pressure level. Flow adjusters incorporated into the mixing valve to limit the maximum flow of hot water
18、shall be set at a flow pressure of 0,3 MPa with the mixing valve flow control fully open in the hot position so that the maximum flow rate, expressed in litres per second, through the hot side of the valve is equal to U120 of the nominal heating power, expressed in kilowatts, of the heater with whic
19、h the mixing valve is expected to be used. Where the mixing valve is to be used with heaters of various heating powers the tests shall be camed out with the flow adjuster set according to both the maximum and minimum nominal heating power. Flow adjusters with a fixed setting or automatic function sh
20、all be left as supplied. If the mixing valve is supplied with a removable outlet accessory such as a shower hose, shower head, flow straightener etc., the test shall be carried out with this in place. Otherwise nothing shall be connected to the mixing valve outlet during the test. 3.7 Fittings for t
21、he connection of household equipment Fittings for the connection of household equipment (washing machines, dish-washers, etc.,) shall be tested as in-line valves (see EN IS0 3822-3) or as draw-off taps (see EN IS0 3822-2), as applicable. 7 STD.BS1 BS EN IS0 3822-q-ENGL 1777 1b24bb7 Ob33782 3T3 m EN
22、IS0 3822-4 : 1997 3.8 Outlet fings 3.8.1 Mounting conditions Shower handsets shall be connected to the test pipe using the arrangement shown in annex D. Shower heads shall be connected to the test pipe using a straight pipe of length 300 mm and of the same nominal bore as the shower head connection.
23、 Other outlet fittings such as aerators, diverters, ball joints, flow controls, anti-backsiphonage valves, etc., shall be connected directly to the test pipe (see 3.1) using an adaptor complying with anno C. 3.8.2 Operating conditions The sound pressure levels of outlet fittings shall be measured at
24、 flow pressures of 0,3 MPa and 0,5 MPa and the flow rates shall be recorded. Outlet fittings such as ball joints, diverters, flow controls, anti-backsiphonage valves etc., which do not incorporate an atmospheric discharge accessory such as an aerator, shower head or handset, etc., shall be tested wi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ENISO382241997ENACOUSTICSLABORATORYTESTSONNOISEEMISSIONFROMAPPLIANCESANDEQUIPMENTUSEDINWATERSUPPLYINSTALLATIONSPART4MOUNTINGANDOPERATINGCONDITIONSFORPDF

链接地址:http://www.mydoc123.com/p-722439.html