DIN 2559-4-1994 Preparation of welds part 4 matching of inside diameters for circumferential welds on seamless pipes of stainless steels《焊缝预加工 第4部分 不锈钢无缝管圆焊缝内径配合》.pdf
《DIN 2559-4-1994 Preparation of welds part 4 matching of inside diameters for circumferential welds on seamless pipes of stainless steels《焊缝预加工 第4部分 不锈钢无缝管圆焊缝内径配合》.pdf》由会员分享,可在线阅读,更多相关《DIN 2559-4-1994 Preparation of welds part 4 matching of inside diameters for circumferential welds on seamless pipes of stainless steels《焊缝预加工 第4部分 不锈钢无缝管圆焊缝内径配合》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Weld preparation Inside diameters of seamless stainless steel pipes In keeping with current practice in standards published by the International Organization for Standardization (ISO), a comma has been used throughout as the decimal marker. DIN - 2559-4 Dimensions in mm d, 1 Scope and field of appli
2、cation This standard illustrates how to calculate the inside diameters required to make seamless steel pipes in compliance with DIN 2462-1 match and form grooves shaped as specified in DIN 2559-1 suitable for one-sided welding. It is to be used for butt-welding pipes supplied by different manufactur
3、ers which have the same nominal diameter but differ in their actual dimensions, and may be applied as appropriate to other cylindrical hollow bodies. Limit deviations 2 Dimensions The matching inside diameter, d, as a function of the nominal wall thickness, t (cf. figures 1 and 2) shall be calculate
4、d using the formulae numbered 1 through 23 in tables 2 to 6, which are based on the following equation: Matching inside diameters which are subject to the limit deviations specified in table 1 are given in tables 7 to 10 as a function of the pipe outside diameter. dp = da iniii - 2 x min Formula No.
5、 1 2 3 4 Pipe outside Nominal wall Formula) used IS0 tolerance class2) diameter, da thickness, t*) to calculate d, da t Up to 48,3 Up to 1,6 da - 0,5 - 2(t - 0,2) Up to 48,3 2 to 11 da - 0,5 - 1,8 t 51 to 219,l Up to 1,6 0,99 da - 2(t - 0,2) 51 to 219,l D2: * 1 %; T3: * 1 %; 0,5 min. 0,2 min. 2 to 1
6、4,2 0,99 da - 1,8 t I Upto120 I Over 120 up to 320 Over 320 Table 2: Cold formed pipes with standard tolerances for da not exceeding 219,l mm I I I I I Rele- vant table 7 l) The values used in the formulae are based on the tolerances for pipe outside diameters and wall thicknesses specified in DIN 2
7、462-1. The values specified for d, in tables 7 to 10 have been specified to the nearest 0,5 or 1 millimetre. *) Taken from DIN 2462-1. Continued on pages 2 to 7. !uth Verlag GmbH, Berlin, hac the exclusive right of cale for German Standards (DIN-Normen). DIN 2559-4 Eng/. Price group 09.96 Sales No.
8、O107 Page2 DIN 2559-4 Formula No. 13 14 15 16 Table 3 Cold formed pipes subject to closer tolerances for da not exceeding 219,l mm Pipe outside Nominal wall Formula) used IS0 tolerance class) diameter, da thickness, t to calculate d, da t 44,5 to 48,3 Up to 3,6 da - 0,75 - 2(t - 0,6) 44,5 to 48,3 4
9、to 11 da - 0,75 - 1,7 t 51 to 21 9,l Up to 3,6 0,985 da - 2(t - 0,6) 51 to 21 9,l 4 to 14,2 0,985 d, - 1,7 t D1: *1,5%; T1: *15%; I0,75 min. I0,60 min. Nominal wall For ) and ), see table 2. Formula No. 17 18 19 20 Rele- vant table Pipe outside Nominal wall Formula) used IS0 tolerance class) diamete
10、r, da thickness, t to calculate d, t da 44,5 to 48,3 Up to 2,9 da - 0,5 - 2(t - 0,4) 44,5 to 48,3 3,2 to 11 da - 0,5 - 1,75 t 51 to 21 9,l Up to 2,9 0,99 d, - 2(t - 0,4) 51 to 21 9,l 3,2 to 14,2 0,99 da - 1,75 t D2: * 1 %; I0,50 min. I0,40 min. T2: * 123%; 3, Use the given formulae to calculate spec
11、ial sizes. The values given for d, have been given to the nearest half or whole millimetre. Table 4: Hot reduced pipes subject to standard tolerances for d, between 44,5 mm and 219,l mm Rele- vant table 8 Table 5: Hot reduced pipes subject to closer tolerances for d, above 4,5 mm Up to 219,l mm Rele
12、- vant table DIN 2559-4 Page3 Formula No. 21 22 23 Table 6: Hot reduced pipes subject to standard tolerances for da above 219,l mm Up to 610 mm Pipe outside Nominal wall Formula) used ISO tolerance ciass2) diameter, da4) thickness, t4) to calculate d, vant t table da - 9 D1: I1,5%; +22,5%; * 0,75 mi
13、n. - 15 % min, D1: I1,5%; T1: I15%; f 0,75 min. f 0,60 min. D1: k 13 %; T2: k 12,5 %; f 0,75 min. f 0,4 min. 219,l to 610 Up to 14,25) 0,985 da - 1,7 t 9 0,985 d, - 1,7 t 219,l to 610 219,l to 610 Up to 14,26) Up to 14,27) 0,985 d, - 1,7 t For l) and 2), see table 2. 4, Refer to DIN 2448 when orderi
14、ng larger diameters and wall thicknesses not covered by DIN 2462-1. 5, t less or equal to 0,05 da. 6, t above 0,05 d, up to 0,09 d,. 7, t greater than 0,09 da. The shapes and dimensions of grooves shall be in compliance with DIN 2559-1. Examples are illustrated below. Figure 1: DIN 2559-21 groove (a
15、fter matching pipes) Figure 2: DIN 2559-4 groove (after matching pipes) 3 Designation The designation for a DIN 2559-21 groove, formed by the matching ends of pipes with an outside diameter, da, of 32 mm and a nominal wall thickness, t, of 2,9 mm, d, having been brought to 26 mm in accordance with t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DIN255941994PREPARATIONOFWELDSPART4MATCHINGOFINSIDEDIAMETERSFORCIRCUMFERENTIALWELDSONSEAMLESSPIPESOFSTAINLESSSTEELS

链接地址:http://www.mydoc123.com/p-655413.html