BS IEC 62548-2016 Photovoltaic (PV) arrays Design requirements《光伏 (PV) 阵列 设计要求》.pdf
《BS IEC 62548-2016 Photovoltaic (PV) arrays Design requirements《光伏 (PV) 阵列 设计要求》.pdf》由会员分享,可在线阅读,更多相关《BS IEC 62548-2016 Photovoltaic (PV) arrays Design requirements《光伏 (PV) 阵列 设计要求》.pdf(72页珍藏版)》请在麦多课文档分享上搜索。
1、Photovoltaic (PV) arrays Design requirementsBS IEC 62548:2016BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06National forewordThis British Standard is the UK implementation of IEC 62548:2016. It supersedes PD IEC/TS 62548:2013 which is withdrawn.The UK participation
2、in its preparation was entrusted to TechnicalCommittee GEL/82, Photovoltaic Energy Systems.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible fo
3、r its correct application. The British Standards Institution 2016.Published by BSI Standards Limited 2016ISBN 978 0 580 88317 0ICS 27.160Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and
4、Strategy Committee on 31 October 2016.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS IEC 62548:2016IEC 62548 Edition 1.0 2016-09 INTERNATIONAL STANDARD NORME INTERNATIONALE Photovoltaic (PV) arrays Design requirements Groupes photovoltaques (PV) Exigences de conce
5、ption INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION ELECTROTECHNIQUE INTERNATIONALE ICS 27.160 ISBN 978-2-8322-3635-2 Registered trademark of the International Electrotechnical Commission Marque dpose de la Commission Electrotechnique Internationale Warning! Make sure that you obtained this p
6、ublication from an authorized distributor. Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agr. colourinsideBS IEC 62548:2016 2 IEC 62548:2016 IEC 2016 CONTENTS FOREWORD . 5 1 Scope and object . 7 2 Normative references. 7 3 Terms, definitions, symbols and
7、 abbreviated terms . 9 3.1 Terms, definitions and symbols 9 3.2 Abbreviations 16 4 Compliance with IEC 60364 (all parts) 16 5 PV array system configuration 16 5.1 General . 16 5.1.1 Functional configuration of a PV system . 16 5.1.2 PV system architectures . 17 5.1.3 Array electrical diagrams 17 5.1
8、.4 Use of PCE with multiple DC inputs 22 5.1.5 Strings constructed using DC conditioning units 23 5.1.6 Series-parallel configuration . 24 5.1.7 Batteries in systems . 25 5.1.8 Considerations due to prospective fault conditions within a PV array . 25 5.1.9 Considerations due to operating temperature
9、 25 5.1.10 Performance issues . 26 5.2 Mechanical design 26 5.2.1 General . 26 5.2.2 Thermal aspects 27 5.2.3 Mechanical loads on PV structures . 27 5.2.4 Corrosion . 27 6 Safety issues . 28 6.1 General . 28 6.1.1 Overview . 28 6.1.2 Separation of PV array from main AC power output circuits . 28 6.2
10、 Protection against electric shock . 29 6.2.1 General . 29 6.2.2 Protective measure: double or reinforced insulation 29 6.2.3 Protective measure: extra-low-voltage provided by SELV or PELV 29 6.3 Protection against thermal effects 29 6.4 Protection against the effects of insulation faults 29 6.4.1 G
11、eneral . 29 6.4.2 Detection and fault indication requirements 30 6.5 Protection against overcurrent . 34 6.5.1 General . 34 6.5.2 Requirement for overcurrent protection . 34 6.5.3 Requirement for string overcurrent protection . 34 6.5.4 Requirement for sub-array overcurrent protection . 35 6.5.5 Ove
12、rcurrent protection sizing 35 6.5.6 Overcurrent protection in PV systems connected to batteries 37 6.5.7 Overcurrent protection location . 37 6.6 Protection against effects of lightning and overvoltage . 38 6.6.1 General . 38 BS IEC 62548:2016IEC 62548:2016 IEC 2016 3 6.6.2 Protection against overvo
13、ltage . 38 7 Selection and erection of electrical equipment 39 7.1 General . 39 7.2 PV array maximum voltage 40 7.3 Component requirements 40 7.3.1 General . 40 7.3.2 PV modules . 41 7.3.3 PV array and PV string combiner boxes 41 7.3.4 Circuit breakers . 42 7.3.5 Fuses 42 7.3.6 Disconnectors and swi
14、tch-disconnectors . 42 7.3.7 Cables . 43 7.3.8 Segregation of AC and DC circuits . 46 7.3.9 Plugs, sockets and connectors . 46 7.3.10 Wiring in combiner boxes . 47 7.3.11 Bypass diodes . 47 7.3.12 Blocking diodes 47 7.3.13 Power conversion equipment (PCE) including DC conditioning units (DCUs) 47 7.
15、4 Location and installation requirements . 48 7.4.1 Disconnecting means . 48 7.4.2 Earthing and bonding arrangements . 49 7.4.3 Wiring system 54 8 Acceptance . 56 9 Operation/maintenance 56 10 Marking and documentation . 56 10.1 Equipment marking . 56 10.2 Requirements for signs 56 10.3 Identificati
16、on of a PV installation 57 10.4 Labelling of PV array and PV string combiner boxes 57 10.5 Labelling of disconnection devices . 57 10.5.1 General . 57 10.5.2 PV array disconnecting device 57 10.6 Documentation 57 Annex A (informative) Examples of signs 58 Annex B (informative) Examples of system fun
17、ctional earthing configurations in PV arrays . 59 Annex C (informative) Blocking diode . 61 C.1 Introduction . 61 C.2 Use of blocking diodes to prevent overcurrent/fault current in arrays 61 C.3 Examples of blocking diode use in fault situations 61 C.3.1 General . 61 C.3.2 Short circuit in PV string
18、 . 61 C.4 Specification of blocking diode 63 C.5 Heat dissipation design for blocking diode . 63 Annex D (informative) Arc fault detection and interruption in PV arrays . 65 Annex E (normative) DVC limits . 66 Bibliography . 67 BS IEC 62548:2016 4 IEC 62548:2016 IEC 2016 Figure 1 General functional
19、configuration of a PV powered system 17 Figure 2 PV array diagram single string example . 18 Figure 3 PV array diagram multiple parallel string example 19 Figure 4 PV array diagram multiple parallel string example with array divided into sub-arrays 20 Figure 5 PV array example using a PCE with multi
20、ple MPPT DC inputs . 21 Figure 6 PV array example using a PCE with multiple DC inputs internally connected to a common DC bus 22 Figure 7 PV string constructed using DC conditioning units . 24 Figure 8 Example of a PV array diagram where strings are grouped under one overcurrent protection device pe
21、r group 36 Figure 9 Examples of reinforced protection of wiring . 45 Figure 10 PV array exposed conductive parts functional earthing/bonding decision tree . 51 Figure 11 Exposed conductive parts earthing in a PV array . 52 Figure 12 Examples of PV string wiring with minimum loop area . 55 Figure A.1
22、 Example of sign required on PV array combiner boxes (10.4) . 58 Figure A.2 Example of switchboard sign for identification of PV on a building 58 Figure B.1 System functional earthing/grounding 59 Figure B.2 Examples different PV configurations in common use . 60 Figure C.1 Effect of blocking diode
23、where there is a short circuit in PV string 62 Figure C.2 Effect of blocking diode where there is an earth fault on a system with earthing on the minus side 62 Figure C.3 Effect of blocking diode where there is an earth fault on a system with positive side earthing 63 Figure D.1 Examples of types of
24、 arcs in PV arrays 65 Table 1 Requirements for different system types based on PCE isolation and PV array functional earthing . 31 Table 2 Minimum insulation resistance thresholds for detection of failure of insulation to earth . 32 Table 3 Rated current of automatic earth fault interrupting means .
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSIEC625482016PHOTOVOLTAICPVARRAYSDESIGNREQUIREMENTS PV 阵列 设计 要求 PDF

链接地址:http://www.mydoc123.com/p-583083.html