1、Erection of electrical installationsin underground minesBS EN 50628:2016BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06National forewordThis British Standard is the UK implementation of EN 50628:2016. The UK participation in its preparation was entrusted to Technica
2、lCommittee EXL/31, Equipment for explosive atmospheres.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The Briti
3、sh Standards Institution 2016.Published by BSI Standards Limited 2016ISBN 978 0 580 88683 6ICS 29.260.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 July 201
4、6. Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 50628:2016EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 50628 July 2016 ICS 29.260.20 English Version Erection of electrical installations in underground mines Construction des installations lectriques da
5、ns les mines souterraines Errichten elektrischer Anlagen im Bergbau unter Tage This European Standard was approved by CENELEC on 2016-05-23. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a
6、national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German
7、). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium,
8、Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Swi
9、tzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CENELEC All rights of exploitation i
10、n any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 50628:2016 E BS EN 50628:2016EN 50628:2016 2 Contents Page European foreword 5 Introduction 6 1 Scope . 7 2 Normative references . 8 3 Terms and definitions 9 4 General . 21 4.1 General requirements . 21 4.2 Initial insp
11、ections 22 4.3 Competence of personnel 22 4.4 Documentation 22 5 Means of protection against electric- and electrostatic charging . 23 6 Rooms and Locations 23 6.1 Electrical service rooms 23 6.2 Closed electrical service rooms 23 6.3 Other rooms 23 7 Protection against fire spreading 24 7.1 General
12、 requirements . 24 8 Insulation, Insulation-resistance and its check . 24 8.1 Insulation . 24 8.2 Value of insulation resistance . 25 8.3 Insulation resistance check . 25 9 Signboards, labels, wiring diagrams, inscriptions 26 9.1 General requirements . 26 10 Nominal voltages 26 10.1 General requirem
13、ents . 26 10.2 Voltage ranges 27 11 Protection against electrical shock 27 11.1 Requirements for basic protection . 27 11.1.1 Protection by basic insulation of live parts . 27 11.1.2 Protection by barriers or enclosures 27 11.1.3 Protection by obstacles and placing out of reach 28 11.2 Requirements
14、for fault protection . 28 12 Protection in IT-Systems 28 12.1 General . 28 12.2 Earth fault detection in IT-systems . 29 12.3 Design of IT system 29 12.4 Insulation monitoring . 30 12.5 Protective conductor 31 12.6 Electrical protection devices in IT-systems . 33 12.7 Design of cables being monitore
15、d by a protection device . 36 13 Protection in TN-systems 37 BS EN 50628:2016EN 50628:2016 3 13.1 TN-S- systems with residual current devices (RCD) . 37 13.2 TN-S System without residual current devices (RCD) . 38 14 Other means of protection . 38 15 Protection against danger caused by mechanical in
16、fluence on non-intrinsically safe cables 38 15.1 General requirements . 38 15.2 Cables to supply mobile electrical equipment . 39 15.3 Cable in areas of mining activities or road heading areas till 50 m far from the road heading face . 40 16 Intrinsically safe electrical systems 40 16.1 General requ
17、irements for selection . 40 16.2 Descriptive system document . 40 16.3 Erection 40 16.4 Separation of intrinsically and non-intrinsically safe circuits 41 16.5 Separation of different intrinsically safe circuits . 42 16.6 Earthing 42 16.7 Cable for intrinsically safe systems 42 17 Installation of tr
18、ansformers 42 18 Substations 42 19 Disconnecting devices in line of each switch-gears . 43 20 Switchgears . 43 21 Couplers and connectors . 43 21.1 General requirements for use of couplers and connectors 43 21.2 Additional requirements using couplers 43 22 Luminaries and lighting installation 44 23
19、Cables . 44 23.1 Design of cables 44 23.2 Conductor materials 45 23.3 Current carrying capacity . 45 23.4 Coverings and outer protective covers. 45 23.5 Different circuits within one cable . 46 23.6 Laying out of cables 46 23.7 Glanding, terminating or making off . 47 23.8 Laying out of non-insulate
20、d conductors . 48 23.9 Additional requirements for the use of single core cable . 49 24 Protection of electrical equipment or installation against overcurrent . 49 24.1 Overcurrent protection devices . 49 24.2 Overload protection 50 24.3 Short circuit protection . 50 24.4 Minimum short circuit curre
21、nt . 51 25 Calculation of short circuit currents . 52 26 Additional requirements for systems and equipment with nominal voltage of more than 1 kV up to 6,6 kV in production areas and road heading 52 26.1 General requirements . 52 26.2 Switchgears . 52 26.3 Test of insulation resistance of non-alive
22、cable in production areas and road headings 52 26.4 Insulation monitoring of alive systems . 53 26.5 Earth protection in IT systems . 53 26.6 Monitoring of non-alive systems . 53 26.7 Electrical protection devices for feeding cables of electrical equipment . 54 BS EN 50628:2016EN 50628:2016 4 26.8 C
23、able design 54 27 Additional requirements for cable entry selection 54 Annex A (informative) Documentation . 55 Annex B (normative) Tables and figures regarding free space . 56 Annex C (informative) Example for a galvanically separated system (in production areas or road headings) . 58 Annex D (info
24、rmative) Example for calculation (according to 12.3.6) . 61 D.1 General . 61 D.2 Legend . 61 D.3 Necessary system parameters 61 D.4 Determination of the reference points of the system . 61 D.5 Calculation of the capacitive earth fault current and displaying in a figure (see Figure D.2) 62 D.6 Overla
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN506282016ERECTIONOFELECTRICALINSTALLATIONSINUNDERGROUNDMINES 地下 矿区 电气 装置 安装 PDF

链接地址:http://www.mydoc123.com/p-575081.html