《BS 7456-1991 Code of practice for stabilization and thermal insulation of cavity walls (with masonry or concrete inner and outer leaves) by filling with polyurethane (PUR) foam sys.pdf》由会员分享,可在线阅读,更多相关《BS 7456-1991 Code of practice for stabilization and thermal insulation of cavity walls (with masonry or concrete inner and outer leaves) by filling with polyurethane (PUR) foam sys.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 7456:1991 Incorporating Amendment No. 1 Code of practice for Stabilization and thermal insulation of cavity walls (with masonry or concrete inner and outer leaves) by filling with polyurethane (PUR) foam systemsBS7456:1991 This British Standard, having been prepared under the dir
2、ection of the Plastics and Rubber Standards Policy Committee, was published underthe authority of the Standards Board and comes intoeffect on 30 September 1991 BSI 10-1999 The following BSI references relate to the work on this standard: Committee reference PRM/72 Draft for comment 88/43769 DC ISBN
3、0 580 19791 3 Committees responsible for this British Standard The preparation of this British Standard was entrusted by the Plastics and Rubber Standards Policy Committee (PRM/-) to Technical Committee PRM/72, upon which the following bodies were represented: Association of Building Component Manuf
4、acturers Brick Development Association British Board of Agrment British Plastics Federation British Rigid Urethane Foam Manufacturers Association Calcium Silicate Brick Association Limited Cavity Foam Bureau Chief and Assistant Chief Fire Officers Association Department of the Environment (Building
5、Research Establishment) Department of the Environment (Construction Directorate) Engineering Equipment and Materials Users Association Flat Roofing Contractors Advisory Board Loss Prevention Council Ministry of Defence National Cavity Insulation Association National Federation of Roofing Contractors
6、 National House-building Council Phenolic Foam Manufacturers Association Polyethylene Foam Insulation Association Royal Institute of British Architects The following bodies were also represented in the drafting of the standard, through subcommittees and panels: British Ceramic Research Ltd. British
7、Urethane Foam Contractors Association (BUFCA) Department of the Environment Department of the Environment (Property Services Agency) RAPRA Technology Ltd. Amendments issued since publication Amd. No. Date Comments 8143 April 1994 Indicated by a sideline in the marginBS7456:1991 BSI 10-1999 i Content
8、s Page Committees responsible Inside front cover Foreword ii 0 Introduction 1 1 Scope 1 2 Definitions 1 3 Suitability of cavity walls 2 4 Polyurethane foam system 2 5 Thermal performance of installed polyurethane foam 2 6 Pre-installation preparation of the building 3 7 Filling process 3 8 Installat
9、ion of the polyurethane foam system 4 9 Post-installation activities 5 10 Declaration 6 11 Records 6 Appendix A Criteria of suitability of external cavity walls 8 Appendix B Fire performance of polyurethane foam when installed in a wall cavity 9 Appendix C Notes for designers 10 Appendix D Flue chec
10、ks for appliances of rated input not exceeding 60 kW 10 Appendix E Methods for determining cavity width 11 Figure 1 Staggered drilling pattern (representing maximum spacing) 4 Figure 2 Elevations of semi-detached property: unit area plan for injection 6 Figure 3 Overall pattern of filling for a nomi
11、nal 50 mm wide cavity 7 Figure 4 Measurement of cavity width 12 Figure 5 Estimation of cavity width 12 Publication(s) referred to Inside back coverBS7456:1991 ii BSI 10-1999 Foreword This British Standard has been prepared under the direction of the Plastics and Rubber Standards Policy Committee fro
12、m a draft prepared by the British Rigid Urethane Foam Manufacturers Association. Greater use is being made of insulation in construction as a consequence of changes in building regulations. The use of polyurethane (PUR) foam provides a means of providing thermal insulation in buildings of cavity wal
13、l construction having inner and outer masonry or concrete leaves, as well as providing a method of restoring the integrity of walls where the wall ties have become inoperative due to corrosion. A system of this type was first certified by the Agrment Board in 1975. This British Standard indicates cr
14、iteria for the selection of suitable buildings and defines the procedures and precautions to be followed to provide for the satisfactory injection of a PUR foam system into the cavity wall. The procedural advice and the controls needed on site have been fully detailed. BS 7457:1994 specifies rigid p
15、olyurethane foam systems which are suitable for use as described in this code of practice. It is recommended that installers have a quality management system complying with the requirements of Part 2 of BS 5750. A British Standard does not purport to include all the necessary provisions of a contrac
16、t. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages1 to 12, an inside back cover
17、 and a back cover This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS7456:1991 BSI 10-1999 1 0 Introduction A suitable polyurethane foam system may be injected into a masonry cavity w
18、all by injecting the liquid polyurethane system through properly spaced holes in the outer leaf. The polyurethane foam system expands in the cavity and sets to become a substantially closed-celled cross-linked rigid polyurethane foam which is strongly adhered to the inner and outer leaves, so that t
19、hese leaves become bonded together. Such a system comprises an isocyanate, a polyol (an isocyanate reactive resin usually containing two or more hydroxyl groups) and an expanding agent, which is a liquid at normal UK ambient temperatures and is usually incorporated as a liquid into the polyol compon
20、ent. Thus the operation consists on site of continuously mixing the two components correctly and inserting the resultant foam system into the cavity. The expansion results from the vapourization of the expanding agent due to the heat generated by reaction of the polyol and isocyanate. Because the st
21、rength of the rigid polyurethane foam is significant the system has been widely used for the restoration of the integrity of cavity walls in which the wall ties have become ineffective due to corrosion. The installed rigid polyurethane foam thus confers two benefits namely insulation and interleaf b
22、onding. Provided that the precautions referred to in this code of practice are followed no hazard should arise during or after installation. It should be stressed that, while polyurethane foam is a satisfactory replacement for normal metal wall ties, it does not prevent corrosion of existing ties in
23、 a wall nor halt the deterioration caused by such corrosion. All installations in walls to deal with corroding wall ties have to be accompanied by a suitable treatment of the existing ties such as removal, isolation (see A.9). 1 Scope This British Standard gives recommendations for the installation
24、of rigid polyurethane (PUR) foam systems complying with BS 7457:1994, which are dispensed on site, to fill cavities of maximum width150 mm of suitably constructed external walls of maximum continuous cavity height 12 m which have masonry or concrete inner and outer leaves, thereby providing addition
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS74561991CODEOFPRACTICEFORSTABILIZATIONANDTHERMALINSULATIONOFCAVITYWALLSWITHMASONRYORCONCRETEINNERANDOUTERLEAVESBYFILLINGWITHPOLYURETHANEPURFOAMSYSPDF

链接地址:http://www.mydoc123.com/p-546819.html