BS 6353-1983 Specification for underground loudspeaker communication systems in coal mines《煤矿用地下扩音通信系统规范》.pdf
《BS 6353-1983 Specification for underground loudspeaker communication systems in coal mines《煤矿用地下扩音通信系统规范》.pdf》由会员分享,可在线阅读,更多相关《BS 6353-1983 Specification for underground loudspeaker communication systems in coal mines《煤矿用地下扩音通信系统规范》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS6353:1983 Specification for Underground loudspeaker communication systems in coal mines UDC 654.939.1:621.395.623.7/.8:622.23BS6353:1983 This BritishStandard, having been prepared under the directionof the Mining and Quarrying Requisites Standards Committee, was published underthe
2、 authority of the BoardofBSI and comes intoeffecton 29April1983 BSI 12-1999 The following BSI references relate to the work on this standard: Committee reference MQE/25 Draft for comment81/75758 DC ISBN 0 580 11939 4 Committees responsible for this BritishStandard This BritishStandard was published
3、under the direction of the Mining and Quarrying Requisites Standards Committee MQE/-. Its preparation was entrusted to Technical Committee MQE/25 upon which the following bodies were represented: Association of British Mining Equipment Companies Council for Electrical Equipment for Flammable Atmosph
4、eres (BEAMA) Health and Safety Executive National Association of Colliery Overmen, Deputies and Shotfirers (NACODS) National Coal Board National Union of Mineworkers Amendments issued since publication Amd. No. Date of issue CommentsBS6353:1983 BSI 12-1999 i Contents Page Committees responsible Insi
5、de front cover Foreword ii 1 Scope 1 2 Definitions 1 3 Electrical interface characteristics 1 4 Interconnection facilities 1 5 Tone signals 1 6 Transmission distance 1 7 Marking 2 8 Documentation 2 Appendix A Design of safety couplers and barriers 4 Appendix B Cable 4 Figure 1 Underground loudspeake
6、r communication system 3 Figure 2 System electrical parameters 3 Figure 3 Safety coupler 4 Figure 4 Safety barrier 5 Table 1 Electrical interface characteristics 2 Publications referred to Inside back coverBS6353:1983 ii BSI 12-1999 Foreword This BritishStandard has been prepared under the direction
7、 of the Mining and Quarrying Requisites Standards Committee. Underground loudspeaker communication systems provide local speech communication and broadcast alarm signals for the safe and efficient operation ofassociated machinery. The systems are generally fitted with facilities for communication wi
8、th the surface and/or for interconnection with other underground communication systems. It is envisaged that it will be necessary to interconnect systems made by different manufacturers and if problems arising from such interconnection are to be avoided, systems have to be compatible. The purpose of
9、 this standard is therefore to promote compatibility between loudspeaker communications systems of different manufacture. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance wi
10、th a British Standard does not of itself confer immunity from legal obligations. Attention is drawn to the Health and Safety at Work etc. Act1974, the Mines and Quarries Act1954, the Regulations made under these Acts, and also any other appropriate statutory requirements or byelaws. These place resp
11、onsibility for complying with certain specific safety requirements on the manufacturer and the user. The address of the recognized certification authority in the United Kingdom for Group1 (coal mining) apparatus for intrinsic safety purposes is as follows: Health and Safety Executive HSE (M) Certifi
12、cation Support Unit Harpur Hill Buxton Derbyshire SK179JN. Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, pages1 to6, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. Thi
13、s will be indicated in the amendment table on the inside front cover.BS6353:1983 BSI 12-1999 1 1 Scope This BritishStandard specifies requirements for underground loudspeaker communication systems that are equipped with the facility for connecting speech and other audio signals to another loudspeake
14、r communication system and/or to an appropriate surface switchboard to form a loudspeaker communication network. Electrical input and output characteristics of underground loudspeaker communication systems necessary to achieve operational compatibility when they are interconnected are specified. The
15、 requirements for tone signals specified in clause5 do not apply to signals that are not transmitted to another system. This standard is applicable to underground loudspeaker communication systems that are intended to be certified intrinsically safe for use in coal mines in accordance with BS5501-9
16、for group I category “ia” systems. This standard is not applicable to mine telephone systems. NOTE 1Further requirements for intrinsic safety are specified in BS1259 and BS5501-7. NOTE 2The titles of the publications referred to in this standard are listed on the inside back cover. 2 Definitions For
17、 the purposes of this BritishStandard the following definitions apply. 2.1 loudspeaker communication system a system incorporating loudspeaker units enabling speech and other audio signals to be broadcast NOTEA typical system is shown in Figure 1. 2.2 loudspeaker unit a device normally comprising a
18、loudspeaker, microphone, amplifying/signalling circuits, and an internal power source 2.3 surface switchboard a manned control desk into which various separate underground loudspeaker communication systems may be extended to allow communication between underground and surface, and enable operator in
19、terconnection of separate systems 2.4 input impedance the electrical impedance presented to a received signal measured at the interconnection between systems 2.5 output impedance the electrical source impedance of a transmitted signal measured at the interconnection between systems 2.6 safety couple
20、r and safety barrier safety devices that are used to limit the transfer of electrical energy between interconnected systems 3 Electrical interface characteristics The electrical interface characteristics of the loudspeaker communication system and the surface switchboard system shall be as given in
21、Table 1. 4 Interconnection facilities 4.1 Each loudspeaker communication system shall include a safety coupler of the type specified in A.1, to allow the connection of audio signals to another loudspeaker communication system and/or to a surface switchboard. NOTEThe safety coupler should be incorpor
22、ated within the enclosure of one of the units forming part of the loudspeaker communication system. 4.2 The surface switchboard shall include safety barriers of the type specified inA.2 to allow the connection of audio signals to each underground loudspeaker communication system. If the surface swit
23、chboard is certified intrinsically safe, it shall include either safety barriers of the type specified inA.2 or safety couplers of the type specified inA.1. 5 Tone signals 5.1 General. Each system shall be designed to prevent the transmission of unwanted signals between systems. 5.2 Call tone. The c
24、all tone, which is used for calling the surface switchboard from underground loudspeaker communication systems, shall meet the following requirements. a) The amplitude shall be as given in Table 1. b) The waveform shall be sinusoidal. c) The frequency shall be either194Hz3% or5kHz3%. The surface swi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS63531983SPECIFICATIONFORUNDERGROUNDLOUDSPEAKERCOMMUNICATIONSYSTEMSINCOALMINES 煤矿 用地 扩音 通信 系统 规范 PDF

链接地址:http://www.mydoc123.com/p-545963.html