ASTM E2430 E2430M-2013(2018) Standard Specification for Expanded Polystyrene (&x201c EPS&x201d ) Thermal Insulation Boards for Use in Exterior Insulation and Finish Systems (&x201c.pdf
《ASTM E2430 E2430M-2013(2018) Standard Specification for Expanded Polystyrene (&x201c EPS&x201d ) Thermal Insulation Boards for Use in Exterior Insulation and Finish Systems (&x201c.pdf》由会员分享,可在线阅读,更多相关《ASTM E2430 E2430M-2013(2018) Standard Specification for Expanded Polystyrene (&x201c EPS&x201d ) Thermal Insulation Boards for Use in Exterior Insulation and Finish Systems (&x201c.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2430/E2430M 13 (Reapproved 2018)Standard Specification forExpanded Polystyrene (“EPS”) Thermal Insulation Boardsfor Use in Exterior Insulation and Finish Systems (“EIFS”)1This standard is issued under the fixed designation E2430/E2430M; the number immediately following the designation
2、indicates the yearof original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification is for flat, uncoat
3、ed expanded poly-styrene thermal insulation boards for use in exterior insulationand finish systems (EIFS).1.2 EIFS producers may have requirements in addition to,or different than, those in this specification.1.3 The values stated in either SI units or inch-pound unitsare to be regarded separately
4、as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.4 This standard does not purport to address all of thesafety concerns, if a
5、ny, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accor-dance with internatio
6、nally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C578 Speci
7、fication for Rigid, Cellular Polystyrene ThermalInsulationE631 Terminology of Building ConstructionsE2110 Terminology for Exterior Insulation and Finish Sys-tems (EIFS)3. Terminology3.1 For general terminology regarding EIFS and building ingeneral, see Terminology E2110 (for EIFS terms) and Termi-no
8、logy E631 (for buildings in general).4. Ordering Information4.1 The following information shall be provided whenshipping materials under this specification.4.1.1 Thickness, width and length,4.1.2 Number of pieces,4.1.3 Shipping address,4.1.4 Required delivery date,4.1.5 Billing information,4.1.6 Cer
9、tificate of compliance with this specification, and4.1.7 EIFS producer name and product name for whichinsulation is to be used.5. Requirements5.1 The thermal insulation boards shall meet the followingrequirements.5.1.1 Insulation boards shall meet the properties listed inTable 1 of Specification C57
10、8 for Type I.5.1.2 Insulation boards shall be made of 100 % virgin EPS.5.1.3 Length1219 mm 48 in. 6 1.6 mm 6116 in.5.1.4 Width610 mm 24 in. 6 1.6 mm 6116 in.5.1.5 Thickness:5.1.5.1 Minimum: 20 mm 34 in. + 1.6 mm 116 in.5.1.5.2 Maximum: as specified.5.1.6 Edge TruenessWhen measured with a straight ed
11、ge,edges shall not deviate more that 0.8 mm 132 in. in 305 mm12 in.5.1.7 Face FlatnessWhen measured across the face with astraight edge, the maximum deviation for the straight edgeshall not exceed more than 0.8 mm 132 in.5.1.8 SquarenessWhen measured on the large flat facefrom one corner to the oppo
12、sing corner, the dimensionalvariations shall not exceed more than 0.8 mm 132 in. in305 mm 12 in.5.1.9 AgingPrior to cutting into individual boards, theinsulation billet shall remain in one of the following states:5.1.9.1 For a minimum of six weeks at ambient tempera-tures and humidity conditions of
13、the storage locations.1This specification is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.58on Exterior Insulation and Finish Systems (EIFS).Current edition approved Sept. 1, 2018. Published September 2018. Originallyapp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME2430E2430M20132018STANDARDSPECIFICATIONFOREXPANDEDPOLYSTYRENEX201CEPSX201DTHERMALINSULATIONBOARDSFORUSEINEXTERIORINSULATIONANDFINISHSYSTEMSX201CPDF

链接地址:http://www.mydoc123.com/p-531114.html