ASTM D7260-2017 red 3125 Standard Practice for Optimization Calibration and Validation of Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) for Elemental Analysis o.pdf
《ASTM D7260-2017 red 3125 Standard Practice for Optimization Calibration and Validation of Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) for Elemental Analysis o.pdf》由会员分享,可在线阅读,更多相关《ASTM D7260-2017 red 3125 Standard Practice for Optimization Calibration and Validation of Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) for Elemental Analysis o.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7260 12D7260 17Standard Practice forOptimization, Calibration, and Validation of InductivelyCoupled Plasma-Atomic Emission Spectrometry (ICP-AES)for Elemental Analysis of Petroleum Products andLubricants1This standard is issued under the fixed designation D7260; the number immediately
2、following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practi
3、ce covers information on the calibration and operational guidance for the multi-element measurements usinginductively coupled plasma-atomic emission spectrometry (ICP-AES).1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibil
4、ityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.1.3 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decis
5、ion on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D4057 Practice for Manual Sampling of Petroleum and Petroleum ProductsD4307 Practi
6、ce for Preparation of Liquid Blends for Use as Analytical StandardsD6299 Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measure-ment System PerformanceD6792 Practice for Quality Management Systems in Petroleum Products, Liquid Fuels, and Lu
7、bricants Testing Laboratories2.2 ICP-AES Related Standards:C1111 Test Method for Determining Elements in Waste Streams by Inductively Coupled Plasma-Atomic Emission SpectroscopyC1109 Practice for Analysis of Aqueous Leachates from Nuclear Waste Materials Using Inductively Coupled Plasma-AtomicEmissi
8、on SpectroscopyD1976 Test Method for Elements in Water by Inductively-Coupled Argon Plasma Atomic Emission SpectroscopyD4951 Test Method for Determination of Additive Elements in Lubricating Oils by Inductively Coupled Plasma AtomicEmission SpectrometryD5184 Test Methods for Determination of Aluminu
9、m and Silicon in Fuel Oils by Ashing, Fusion, Inductively Coupled PlasmaAtomic Emission Spectrometry, and Atomic Absorption SpectrometryD5185 Test Method for Multielement Determination of Used and Unused Lubricating Oils and Base Oils by InductivelyCoupled Plasma Atomic Emission Spectrometry (ICP-AE
10、S)D5600 Test Method for Trace Metals in Petroleum Coke by Inductively Coupled Plasma Atomic Emission Spectrometry(ICP-AES)D5708 Test Methods for Determination of Nickel, Vanadium, and Iron in Crude Oils and Residual Fuels by Inductively CoupledPlasma (ICP) Atomic Emission SpectrometryD6130 Test Meth
11、od for Determination of Silicon and Other Elements in Engine Coolant by Inductively Coupled Plasma-AtomicEmission Spectroscopy1 This practice is under the jurisdiction of ASTM Committee D02 on Petroleum Products Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D
12、02.03 on Elemental Analysis.Current edition approved June 1, 2012June 1, 2017. Published August 2012June 2017. Originally approved in 2006. Last previous edition approved in 20062012 asD7260D7260 12.06. DOI: 10.1520/D7260-12.10.1520/D7260-17.2 For referencedASTM standards, visit theASTM website, www
13、.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of wha
14、t changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the
15、 official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1D6349 Test Method for Determination of Major and Minor Elements in Coal, Coke, and Solid Residues from
16、 Combustion ofCoal and Coke by Inductively Coupled PlasmaAtomic Emission SpectrometryD6357 Test Methods for Determination of Trace Elements in Coal, Coke, and Combustion Residues from Coal UtilizationProcesses by Inductively Coupled Plasma Atomic Emission Spectrometry, Inductively Coupled Plasma Mas
17、s Spectrometry,and Graphite Furnace Atomic AbD7040 Test Method for Determination of Low Levels of Phosphorus in ILSAC GF 4 and Similar Grade Engine Oils byInductively Coupled Plasma Atomic Emission SpectrometryD7111 Test Method for Determination of Trace Elements in Middle Distillate Fuels by Induct
18、ively Coupled Plasma AtomicEmission Spectrometry (ICP-AES)D7303 Test Method for Determination of Metals in Lubricating Greases by Inductively Coupled Plasma Atomic EmissionSpectrometryD7691 Test Method for MultielementAnalysis of Crude Oils Using Inductively Coupled PlasmaAtomic Emission Spectrometr
19、y(ICP-AES)D7876 Practice for Practice for Sample Decomposition Using Microwave Heating (With or Without Prior Ashing) for AtomicSpectroscopic Elemental Determination in Petroleum Products and LubricantsD8056 Guide for Elemental Analysis of Crude OilE1479 Practice for Describing and Specifying Induct
20、ively Coupled Plasma Atomic Emission Spectrometers2.3 Other Standards:IP 437 Determination of Additive Elements in Unused Lubricating Oils and Additive Packages by Inductively CoupledPlasma-Atomic Emission Spectrometry3ISO/TC 17/SC 1 N 883 Guidelines for the Preparation of Standard Methods of Analys
21、is Using Inductively CoupledPlasma-Atomic Emission Spectrometry and for Use of ICP Spectrometry for the Determination of Chemical Composition(1991)43. Summary of Practice3.1 An Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) instrument is one that is used to determineelemental comp
22、osition of various liquid matrices. Details of the instrument components are given in Practice E1479. This practicesummarizes the protocols to be followed during calibration and verification of the instrument performance.4. Significance and Use4.1 Accurate elemental analysis of petroleum products an
23、d lubricants is necessary for the determination of chemical properties,which are used to establish compliance with commercial and regulatory specifications.4.2 Inductively Coupled Plasma-Atomic Emission Spectrometry is one of the more widely used analytical techniques in the oilindustry for multi-el
24、ement analysis as evident from at least twelve standard test methods (for example, Test Methods C1111,D1976, D4951, D5184, D5185, D5600, D5708, D6130, D6349, D6357, D7040, D7111, D7303, and D7691) published for theanalysis of fossil fuels and related materials. These have been briefly summarized by
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD72602017RED3125STANDARDPRACTICEFOROPTIMIZATIONCALIBRATIONANDVALIDATIONOFINDUCTIVELYCOUPLEDPLASMAATOMICEMISSIONSPECTROMETRYICPAESFORELEMENTALANALYSISOPDF

链接地址:http://www.mydoc123.com/p-524971.html