ASTM D926-2004 Standard Test Method for Rubber Property&8212 Plasticity and Recovery (Parallel Plate Method)《橡胶特性的标准试验方法 塑性和回复性(平行板测量法)》.pdf
《ASTM D926-2004 Standard Test Method for Rubber Property&8212 Plasticity and Recovery (Parallel Plate Method)《橡胶特性的标准试验方法 塑性和回复性(平行板测量法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D926-2004 Standard Test Method for Rubber Property&8212 Plasticity and Recovery (Parallel Plate Method)《橡胶特性的标准试验方法 塑性和回复性(平行板测量法)》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 926 04Standard Test Method forRubber PropertyPlasticity and Recovery (Parallel PlateMethod)1This standard is issued under the fixed designation D 926; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers the determination
3、 of plasticityand recovery of unvulcanized rubber by means of the parallelplate plastometer. Uncompounded, compounded, and reclaimrubber may be tested.NOTE 1ISO 2007 and D 3194 use a principle similar to this testmethod although the apparatus, test conditions, and procedure are differ-ent.1.2 The va
4、lues stated in SI units are to be regarded as thestandard. The values in parentheses are for information only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safet
5、y and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 3194 Test Method for Rubber From Natural SourcesPlasticity Retention Index (PRI)D 3767 Practice for Rubber-Measurement of DimensionsD 4483 Practice for Determin
6、ing Precision for Test MethodStandards in the Rubber and Carbon Black IndustriesE 145 Specification for Gravity-Convection and Forced-Ventilation Ovens2.2 ISO Standard:32007 Rubber UnvulcanizedDetermination of PlasticityRapid Plastimeter Method3. Summary of Test Method3.1 Plasticity:3.1.1 A specimen
7、 of specific volume and height is tested atroom temperature or heated to a specified test temperature for15 min and then subjected to a compressive force of 49 N fora specified time.3.1.2 At the end of this time, the height of the specimen ismeasured, and the plasticity number is calculated.3.2 Reco
8、veryThere are two recovery procedures.3.2.1 Procedure AThe test specimen is removed from theplastometer immediately after the determination of plasticityand allowed to cool and recover some of its original height for1 min. The height is measured again and the recovery iscalculated.3.2.2 Procedure BT
9、he test specimen is compressed to aheight of 5 mm for 30 s and then allowed to recover at the testtemperature for 5 min. The height is measured again and therecovery is calculated.4. Significance and Use4.1 The plasticity number and the recovery of the testspecimen are related to the flow properties
10、 and the elasticproperties, respectively, and may be useful in predictingprocessing characteristics, such as ease of forming and extru-sion characteristics.4.1.1 In this test method, plasticity is measured in an inversemanner, as noted by the final height of the specimen. Thus,high plasticity rubber
11、s (high degree of flow during test) areindicated by a low plasticity number.5. Apparatus5.1 The essential features of the parallel plate plastometer,illustrated in Fig. 1, are as follows:5.1.1 Two metal plates, not less than 10 mm in thicknessand 40 mm in diameter, shall be mounted on a suitable fra
12、meso that one plate moves with respect to the other, and so that thetwo plates are parallel within 0.017 rad (1) at all times.5.1.2 The apparatus shall be so designed that a specimenbetween the parallel plates is subjected to a force of 49 6 0.5N, including the effect of the spring in the dial gage
13、during test.1This test method is under the jurisdiction of ASTM committee D11 on Rubberand is the direct responsibility of Subcommittee D11.12 in Processability Tests.Current edition approved June 1, 2004. Published June 2004. Originallyapproved in 1956. Last previous edition approved in 2002 as D 9
14、26 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute,
15、25 West 43rd St., 4thFloor, New York, NY 10036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.1.3 A digital or dial indicator gage calibrated in hun-dredths of a millimetre (0.01 mm) shall be mounted on theapparatus in such a mann
16、er that the distance between the platescan be determined at all times.5.1.4 When required, the apparatus shall be operated in anyoven, as described in Specification E 145, that is capable ofcontaining the plastometer.5.1.5 A separate dimensional measurement gage is requiredfor performing recovery me
17、asurements. The apparatus andmethodology described in Practice D 3767, Procedure A, shallbe employed when performing these measurements.5.2 Test SurfacesFilms or material with low coefficientsof friction to prevent sticking of the test specimen to the plates.The most commonly used test surface is po
18、lyester film.4NOTE 2The test surface used can affect the plasticity number. Evendifferent grades of the same type of polyester film can cause differentresults. When comparing results, the same test surface must be used.6. Sampling6.1 Samples may be taken from raw rubber or unvulcanizedrubber compoun
19、ds undergoing processing operations.7. Test Specimens7.1 The specimen shall be a right cylinder 2.00 6 0.02 cm3in volume and be free from air pockets. (A cylinder 16 mm indiameter and 10 mm in height is appropriate.) The specimenmay be prepared from either a solid piece or plied sheets ofunvulcanize
20、d rubber approximately 1.5 mm in thickness, carebeing taken to exclude air pockets in the sheet. The specimensmay be cut from the sheet either by means of two mating diesconforming to Fig. 2, which produce cylinders of the correctvolume, or a rotating die having an internal diameter ofapproximately
21、16 mm. If a rotating die is used, the height of thecylinder shall be adjusted until the volume is 2.00 6 0.02 cm3.If the density is known, weighing may be used to adjust to thecorrect volume. If necessary, the specimen shall be placed in asuitable holder so that it is not appreciably deformed before
22、testing.8. Test Conditions8.1 The plasticity and recovery values obtained for a givensample will depend largely upon the manner in which the testspecimen is prepared. It is therefore imperative that whencomparisons are made between similar materials, the testspecimen preparation should be in accorda
23、nce with somerigidly specified method. This is necessary because the plas-ticity and recovery may be affected by the amount of mechani-cal working and the conditions under which such work is done.This effect is not constant for all materials. The time intervalbetween test specimen preparation and te
24、sting is important andshould be the same for test specimens between which com-parisons are to be made.8.2 The test temperature shall be 23 (room temperature), 40,70, 85, or 100C unless another temperature is agreed upon.The most frequently used temperature is 23C.8.3 Readings may be taken at any des
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD9262004STANDARDTESTMETHODFORRUBBERPROPERTY8212PLASTICITYANDRECOVERYPARALLELPLATEMETHOD 橡胶 特性 标准

链接地址:http://www.mydoc123.com/p-512518.html