ANSI UL 14C-2006 UL Standard for Safety Swinging Hardware for Standard Tin-Clad Fire Doors Mounted Singly and in Pairs (Eighth Edition Reprint with Revisions Through and Including .pdf
《ANSI UL 14C-2006 UL Standard for Safety Swinging Hardware for Standard Tin-Clad Fire Doors Mounted Singly and in Pairs (Eighth Edition Reprint with Revisions Through and Including .pdf》由会员分享,可在线阅读,更多相关《ANSI UL 14C-2006 UL Standard for Safety Swinging Hardware for Standard Tin-Clad Fire Doors Mounted Singly and in Pairs (Eighth Edition Reprint with Revisions Through and Including .pdf(35页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 14C Swinging Hardware for Standard Tin-Clad Fire Doors Mounted Singly and in Pairs STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT
2、PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Swinging Hardware for Standard Tin-Clad Fire Doors Mounted Singly and in Pairs, UL 14C Eighth Edition, Dated October 27, 2006 Summary of Topics This
3、 revision of ANSI/UL 14C is being issued to update the title page to reect the reaffirmation of the ANSI approval. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. The requirements are substantially in accordance w
4、ith Proposal(s) on this subject dated May 26, 2017. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this
5、 Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots,
6、 lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Stan
7、dard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviati
8、on introduced while purchaser is storing an electronic Standard on the purchasers computer system. JULY 17, 2017 UL 14C tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JULY 17, 2017 UL 14C tr2 No Text on This PageUL COPYRIGHTED MATERIAL N
9、OT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 27, 2006 (Title Page Reprinted: July 17, 2017) 1 UL 14C Standard for Swinging Hardware for Standard Tin-Clad Fire Doors Mounted Singly and in Pairs First Edition March, 1917 Second Edition May, 1943 Third Editi
10、on September, 1968 Fourth Edition June, 1973 Fifth Edition January, 1979 Sixth Edition December, 1993 Seventh Edition January, 1999 Eighth Edition October 27, 2006 This ANSI/UL Standard for Safety consists of the Eighth edition including revisions through July 17, 2017. The most recent designation o
11、f ANSI/UL 14C as a Reaffirmed American National Standard (ANS) occurred on July 17, 2017. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, and Title Page. The Department of Defense (DoD) has adopted UL 14C on October 29, 1984. The publication of revised pages or a new
12、 edition of this Standard will not invalidate the DoD adoption. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs St
13、andards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2017 UNDERWRITERS LABORA
14、TORIES INC. ANSI/UL 14C-2008 (R2017)UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OCTOBER 27, 2006 UL 14C 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONT
15、ENTS INTRODUCTION 1 Scope .5 2 Units of Measurement .6 3 Undated References 6 CONSTRUCTION 4 General 6 5 Hinges for Doors Mounted Singly and in Pairs .6 5.1 Hinge straps 6 5.2 Hinge brackets .8 5.3 Hinge wall strips 8 5.4 Hinge wall strip bolts 8 5.5 Bolts for attaching hinge straps to doors .8 5.6
16、Washers .9 5.7 Hinge locations .9 6 Locking Mechanisms for Doors Mounted Singly and in Pairs .10 6.1 Latch straps .10 6.2 Pivot plates .12 6.3 Latch guides 12 6.4 Latch connecting bars 12 6.5 Latch catches .13 6.6 Latch catch wall strips 15 6.7 Latch catches for doors mounted in pairs .15 6.8 Bolts
17、for attaching catches doors mounted in pairs .15 6.9 Operating handle mechanisms 15 6.10 Handles .15 6.11 Spindles .16 6.12 Operating levers 16 6.13 Center latch guides 16 6.14 Latch springs .16 6.15 Number of latches .17 7 Nonautomatic Double-Acting Bolt Mechanisms for Standing Doors of Doors in Pa
18、irs .17 7.1 General .17 7.2 Top and bottom bolts 19 7.3 Top and bottom bolt keepers .19 7.4 Connecting rods .19 7.5 Connecting rod guides .19 7.6 Operating plate and handle .20 7.7 Bottom bolt catches for double-acting bolts .20 7.8 Top bolt catches for double-acting bolts 22 8 Installation Instruct
19、ions .24 9 Painting 24 MARKING 10 General 24 OCTOBER 27, 2006 UL 14C 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL APPENDIX A APPENDIX B OCTOBER 27, 2006 UL 14C 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUT
20、ION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements apply to hardware for swinging re doors which have demonstrated in re tests re-resistive properties warranting their use with two-ply and three-ply tin-clad re doors tested in accordance with the Standard for Fire Tests of Do
21、or Assemblies, UL 10B (NFPA No. 252). 1.1 revised December 15, 2008 1.2 Requirements for the location and time rating required for re doors are contained in the International Building Code (IBC). Requirements for the installation of swinging two-ply and three-ply tin-clad re doors are included in th
22、e Standard for Fire Doors and Other Opening Protectives, NFPA No. 80. 1.2 revised December 15, 2008 1.3 The hardware included in these requirements is intended for mounting standard two-ply and three-ply tin-clad swinging re doors for protection of openings not exceeding the dimensions for the hourl
23、y classications indicated in Table 1.1. Table 1.1 Limitations in types and dimensions Type of door Maximum area, Maximum width, Maximum height, Hourly rating or class designation square feet (m 2 ) feet (m) feet (m) 3-ply, single 6 1.8 12 3.6 3, 1-1/2, 1, 3/4 3-ply, in pairs 10 3.1 12 3.6 3, 1-1/2,
24、1, 3/4 2-ply, single 6 1.8 10 3.1 1-1/2, 1, 3/4 2-ply, in pairs 80 7.4 10 3.1 10 3.1 1-1/2, 1, 3/4 1.4 These requirements do not cover automatic releasing or closing mechanisms. 1.5 Deleted December 15, 2008 DECEMBER 15, 2008 UL 14C 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL14C2006ULSTANDARDFORSAFETYSWINGINGHARDWAREFORSTANDARDTINCLADFIREDOORSMOUNTEDSINGLYANDINPAIRSEIGHTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGPDF

链接地址:http://www.mydoc123.com/p-438907.html