1、T 1013 om-10 OFFICIAL TEST METHOD 1992 WITHDRAWN 2000 REVISED AND REINSTATED 2006 REAFFIRMED 2010 2010 TAPPI The information and data contained in this document were prepared by a technical committee of the Association. The committee and the Association assume no liability or responsibility in conne
2、ction with the use of such information or data, including but not limited to any liability under patent, copyright, or trade secret laws. The user is responsible for determining that this document is the most recent edition published. Approved by the Standard Specific Interest Group for this Test Me
3、thod TAPPI CAUTION: This Test Method may include safety precautions which are believed to be appropriate at the time of publication of the method. The intent of these is to alert the user of the method to safety issues related to such use. The user is responsible for determining that the safety prec
4、autions are complete and are appropriate to their use of the method, and for ensuring that suitable safety practices have not changed since publication of the method. This method may require the use, disposal, or both, of chemicals which may present serious health hazards to humans. Procedures for t
5、he handling of such substances are set forth on Material Safety Data Sheets which must be developed by all manufacturers and importers of potentially hazardous chemicals and maintained by all distributors of potentially hazardous chemicals. Prior to the use of this method, the user must determine wh
6、ether any of the chemicals to be used or disposed of are potentially hazardous and, if so, must follow strictly the procedures specified by both the manufacturer, as well as local, state, and federal authorities for safe use and disposal of these chemicals. Loss on ignition of fiber glass mats 1. Sc
7、ope This method covers the determination of the percent loss on ignition of fiber glass mats. This ignition loss can be considered to be the binder content. 2. Applicable documents 2.1 TAPPI T 658 “Properties of Diatomaceous Silica” (Section 5) (withdrawn 1998). 2.2 TAPPI T 1007 “Sample Location.” 3
8、. Summary of method Fiber glass mat is ignited in a muffle furnace at 1157 45F (625 25C) until only an ash and the glass fiber remain. The residue is weighed and the percent loss on ignition of the moisture-free mat is calculated. (Appropriate ventilation should be used when conducting this test to
9、avoid exposure to potentially hazardous products of combustion.) 4. Significance The loss on ignition of fiber glass mat may consist of: binders used to hold the glass fibers together, fibers with an ignition temperature lower than 1157F (625C), and materials used to coat the glass fibers. 5. Appara
10、tus 5.1 Balance, accurate to 0.001 g. 5.2 Drying oven, equipped with a means of constant temperature regulation and mechanical air convection. 5.3 Electric muffle furnace, capable of maintaining a temperature of 1157 45F (625 25C). 5.4 Crucible, high form, 250 mL. 5.5 Desiccator. T 1013 om-10 Loss o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIT1013OM2006LOSSONIGNITIONOFFIBERGLASSMATSPDF

链接地址:http://www.mydoc123.com/p-438051.html