NAVY MIL-DTL-19246 E-2007 CONNECTOR OXYGEN MASK HOSE TYPE MC-3A《MC-3A型氧气罩软管连接器》.pdf
《NAVY MIL-DTL-19246 E-2007 CONNECTOR OXYGEN MASK HOSE TYPE MC-3A《MC-3A型氧气罩软管连接器》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-DTL-19246 E-2007 CONNECTOR OXYGEN MASK HOSE TYPE MC-3A《MC-3A型氧气罩软管连接器》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、INCH-POUNDMIL-DTL-19246E 05 February 2007 SUPERSEDING MIL-DTL-19246D 27 December 2000 DETAIL SPECIFICATION CONNECTOR, OXYGEN MASK HOSE, TYPE MC-3A This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 This specification covers type MC-3A ox
2、ygen mask hose connector for connecting the oxygen mask hose to the oxygen regulator hose. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specif
3、ication or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3 and 4 of this specification, whether or not they ar
4、e listed. 2.2 Government documents. Comments, suggestions, or questions on this document should be addressed to: Commander, Naval Air Warfare Center Aircraft Division, Code 491000B120-3, Highway 547, Lakehurst, NJ 08733-5100 or emailed to thomas.omaranavy.mil. Since contact information can change, y
5、ou may want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil. Reactivated after 05 February 2007 and may be used for new and existing designs and acquisitions. AMSC N/A FSC 1660 Provided by IHSNot for ResaleNo reproduction or networking
6、 permitted without license from IHS-,-,-MIL-DTL-19246E 2 2.2.1 Specifications and standards. The following specifications and standards form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contra
7、ct. DEPARTMENT OF DEFENSE SPECIFICATIONS MS22016 - Connector, Oxygen Mask Hose, Type MC-3A. (Inactive for New Design) MS22058 - Connector, Oxygen Hose to Regulator MIL-PRF-27210 - Oxygen, Aviators Breathing, Liquid and Gas DEPARTMENT OF DEFENSE STANDARDS MIL-STD-129 - Military Marking for Shipment a
8、nd Storage MIL-STD-130 - Identification Marking of U.S. Military Property MIL-STD-810 - Environmental Engineering Considerations and Laboratory Tests MIL-STD-889 - Dissimilar Metals (Copies of these documents and standards are available online at http:/assist.daps.dla.mil/quicksearch/ or http:/assis
9、t.daps.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Bldg 4D, Philadelphia, PA 19111-5094.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents a
10、re those cited in the solicitation or contract. AMERICAN SOCIETY FOR QUALITY (ASQ) ASQ-Z1.4 - Procedures, Sampling and Tables for Inspection by Attributes. (DoD adopted) (Copies of the above document are available from the American Society for Quality, 600 North Plankinton Avenue, Milwaukee, WI 5320
11、1-4606 or http:/www.asq.org.) AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) ASTM-D1149 - Rubber Deterioration Surface Ozone Cracking in a Chamber. (DoD adopted) (Copies of the above document are available from the American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohock
12、en, PA 19428-2959 or http:/www.astm.org.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-19246E 3 2.4 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this documen
13、t takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Qualification. The connector furnished under this specification shall be a product that is authorized by the qualifying activity for li
14、sting on the applicable qualified products list before contract award (see 4.2 and 6.3). 3.2 First article. When specified (see 6.2), a sample shall be subjected to first article inspection in accordance with 4.3. 3.3 Materials. Materials shall be as specified herein and in MS22016 and MS22058. 3.3.
15、1 Nonmetallic materials. Nonmetallic materials, except for the poppet material as shown on MS22016, shall be of an ozone-resistant composition. 3.3.1.1 Age. Age of elastomer components shall be not greater than 12 months from the date of manufacture to the date of delivery to any Government service
16、or to any airframe or accessory manufacturer. 3.3.2 Metal Parts. All metal parts shall be of a corrosion resistant material or treated to render them resistant to corrosion. 3.3.2.1 Dissimilar metals. Unless protected against electrolytic corrosion, dissimilar metals, in accordance with MIL-STD-889,
17、 shall not be in intimate contact with each other. 3.3.3 Protective treatment. When materials used in the construction of the connector assembly are subject to deterioration when exposed to environmental conditions likely to occur during service usage, they shall be protected against such deteriorat
18、ion that shall in no way prevent compliance with the performance requirements (see 3.5) of this specification. Protective coatings which crack, chip, or scale during normal service life or under extremes of environmental conditions shall not be used. 3.4 Design and construction. The design and const
19、ruction of the connector assembly shall be in accordance with MS22016. 3.4.1 Connector assembly valves. Connector assembly valves shall make it possible for the user to breathe normally through the connector when the valve is inserted into a connector conforming to MS22058. When disconnected, the va
20、lve shall permit inhalation, but a noticeable Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-19246E 4 resistance shall be introduced to indicate that disconnection has occurred. A spring-loaded relief valve shall be located in the connector
21、body and adjusted to allow oxygen from the bailout cylinder to escape whenever the mask pressure exceeds a pressure equal to 12 inches of water greater than ambient pressure. The relief valve shall vent small flows before the mask pressure reaches 12 inches of water greater than ambient pressure. 3.
22、4.2 Bailout attachment. The side bailout attachment shall contain a check valve as shown on MS22016. 3.5 Performance. 3.5.1 Disconnection force. The connector shall disconnect between 12 and 20 pounds when tested as specified in 4.7.2. 3.5.2 Leakage (room temperature and extreme temperature). Leakag
23、e of the connector assembly shall be not greater than 0.01 liter per minute (Lpm) when tested as specified in 4.7.3, 4.7.9 and 4.7.10. 3.5.3 Relief valve setting. The connector shall meet the following requirements when tested as specified in 4.7.4: Flow (Lpm) Developed Pressure (inches of water) 2.
24、5 less than 12 12.0 between 11 and 15 50.0 between 12 and 18 3.5.4 Pressure drop through MC-3A connector. The pressure drop through the connector shall be not less than 4 inches nor greater than 6 inches of water when tested as specified in 4.7.5. 3.5.5 Pressure drop through MC-3A connector with MS2
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL19246E2007CONNECTOROXYGENMASKHOSETYPEMC3AMC3A 氧气 软管 连接器 PDF

链接地址:http://www.mydoc123.com/p-978491.html