1、 WORLDWIDE ENGINEERING STANDARDS Test Procedure GMW15432 Irradiation Testing Copyright 2012 General Motors Company All Rights Reserved May 2012 Originating Department: GME Specification Center Page 1 of 5 1 Scope Note: Nothing in this standard supercedes applicable laws and regulations. Note: In the
2、 event of conflict between the English and domestic language, the English language shall take precedence. 1.1 Purpose. This standard measures the stability of interior trim part, e.g., instrument panel; when exposed to elevated surface temperatures. 1.2 Foreword. Not applicable. 1.3 Applicability. I
3、nterior trim parts (e.g., instrument panel) exposed to elevated surface temperatures. 2 References Note: Only the latest approved standards are applicable unless otherwise specified. 2.1 External Standards/Specifications. None 2.2 GM Standards/Specifications. None 3 Resources 3.1 Facilities. Not app
4、licable. 3.2 Equipment. 3.2.1 Assembly and all final assembly components. 3.2.2 Holding Fixture. This fixture should be sturdy construction capable of sustaining temperatures of +150 C for extended periods of time. The fixture must support the part with attachment points simulating the in-car positi
5、on. 3.2.3 Production fasteners and torque values to attach assembly to the fixture. 3.2.4 Vertical height measuring gage accurate to 0.03 mm. 3.2.5 “T” type thermocouples and Leeds Northrup recorder, or equivalent, for monitoring temperatures associated with the test. 3.2.6 Heat chamber with infrare
6、d (IR) heaters capable of producing the classification temperature (surface temperature in horizontal area) per Table 1 Chamber Temperatures on the surface of the part and a control system that prevents over-shooting the desired temperature. Example test equipment set up see Appendix A, Figures A1 a
7、nd A2. The box with air circulation shall also be able to maintain an ambient air temperature per Table 1. Copyright General Motors Company Provided by IHS under license with General Motors CompanyNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-GM WORLDWIDE ENGINEE
8、RING STANDARDS GMW15432 Copyright 2012 General Motors Company All Rights Reserved May 2012 Page 2 of 5 Table 1: Chamber Temperatures Code Classification Temperature in C Ambient Temperature in C A +130 r 3 +90 r 3 B +102 r 3 +74 r 3 C According to special data 3.2.7 Marble table or other stable, fla
9、t, level surface for base on which to take measurements. 3.2.8 Climatic chamber capable of producing the environmental cycle according to Table 2. Table 2: Environmental Cycle Time Condition +24 r 1 h +40 r 3C, 93 r 5% RH Note 1 +24 r 1 h -30 r 3C +24 r 1 h +110 r 3C Note 1: RH = Relative humidity 3
10、.3 Test Vehicle/Test Piece. 3.3.1 Tempilabels (heat sensitive labels). 3.3.2 Cyanoacrylate adhesive and primer for bonding the thermocouples to the part. The usage of an applicable adhesive tape is also allowed. 3.4 Test Time. Not applicable. 3.5 Test Required Information. Not applicable. 3.6 Person
11、nel/Skills. Not applicable. 4 Procedure 4.1 Preparation. Not applicable. 4.2 Conditions. 4.2.1 Environmental Conditions. 4.2.2 Test Conditions. Deviations from the requirements of this standard shall have been agreed upon. Such requirements shall be specified on component drawings, test certificates
12、, reports, etc. 4.3 Instructions. 4.3.1 Mount the part or assembly on the appropriate holding fixture using production fasteners and torques. 4.3.2 The dimensionally monitored points may be chosen by the test engineer in order of best description of the test parts surface or as requested by the subm
13、itter. 4.3.3 Place the fixture and assembly on the marble table. 4.3.4 Observe the assembly closely. Note and record any irregularities or imperfections. 4.3.5 Measure and record the vertical height dimensions of the points marked in paragraph 4.3.2 to an accuracy of 0.03 mm. 4.3.6 Place the assembl
14、y in the heat chamber taking care to center it below the IR heaters. 4.3.7 Using primer and cyanoacrylate adhesive respective the adhesive tape, attach a minimum of five (5) thermocouples across the top surface of the part. Ensure that there are thermocouples on the highest points of tested part, e.
15、g. on the instrument hood of an instrument panel. The other thermocouples may be evenly distributed over the surface of the part. They should be centered from front to back. The thermocouples must be completely covered by the adhesive and tape respectively. The number of heaters may vary. It is impo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMWGMW154322012IRRADIATIONTESTINGISSUE2ENGLISHPDF

链接地址:http://www.mydoc123.com/p-757652.html