EN 60086-2-2011 en Primary batteries - Part 2 Physical and electrical specifications (Remains Current)《原电池 第2部分 物理和电气规范》.pdf
《EN 60086-2-2011 en Primary batteries - Part 2 Physical and electrical specifications (Remains Current)《原电池 第2部分 物理和电气规范》.pdf》由会员分享,可在线阅读,更多相关《EN 60086-2-2011 en Primary batteries - Part 2 Physical and electrical specifications (Remains Current)《原电池 第2部分 物理和电气规范》.pdf(66页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationPrimary batteriesPart 2: Physical and electrical specificationsBS EN 60086-2:2011National forewordThis British Standard is the UK implementation of EN 60086-2:2011. It is identic
2、al to IEC 60086-2:2011. It supersedes BS EN 60086-2:2007, which will be withdrawn on 24 March 2014.The UK participation in its preparation was entrusted to Technical Committee CPL/35, Primary cells.A list of organizations represented on this committee can be obtained on request to its secretary.This
3、 publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. BSI 2011ISBN 978 0 580 69237 6 ICS 29.220.10Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published und
4、er the authority of the Standards Policy and Strategy Committee on 30 June 2011.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 60086-2:2011EUROPEAN STANDARD EN 60086-2 NORME EUROPENNE EUROPISCHE NORM March 2011 CENELEC European Committee for Electrotechnical Stan
5、dardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60086-2:2011
6、E ICS 29.220.10 Supersedes EN 60086-2:2007English version Primary batteries - Part 2: Physical and electrical specifications (IEC 60086-2:2011) Piles primaires - Partie 2: Spcifications physiques et lectriques (CEI 60086-2:2011) Primrbatterien - Teil 2: Physikalische und elektrische Spezifikationen
7、(IEC 60086-2:2011) This European Standard was approved by CENELEC on 2011-03-24. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists a
8、nd bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the respo
9、nsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France
10、, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 60086-2:2011 - 2 - Foreword The text of document 35/1271/CDV, future edition 12 of
11、IEC 60086-2, prepared by IEC TC 35, Primary cells and batteries, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60086-2 on 2011-03-24. This European Standard supersedes EN 60086-2:2007. Significant changes from EN 60086-2:2007 are the deletion of eight battery types
12、 from this standard, the addition of an air hole placement diagram and deletion of the resistive hearing aid tests for the P-system (zinc air) hearing aid batteries, standardization of a new form of alkaline (L-system) 9 volt battery (6LP3146), addition of a common designation reference as Annex D a
13、nd general adjustment of application tests and their minimum average duration values to reflect changes in battery usage. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifyin
14、g any or all such patent rights. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2011-12-24 latest date by which the national standards conflicting with the EN have to be with
15、drawn (dow) 2014-03-24 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 60086-2:2011 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the sta
16、ndards indicated: IEC 60086-3 NOTE Harmonized as EN 60086-3. IEC 60086-4 NOTE Harmonized as EN 60086-4. IEC 60086-5 NOTE Harmonized as EN 60086-5. IEC 62281 NOTE Harmonized as EN 62281. _ - 3 - EN 60086-2:2011 Annex ZA (normative) Normative references to international publications with their corresp
17、onding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an interna
18、tional publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60086-1 2011 Primary batteries - Part 1: General EN 60086-1 2011 ISO 1101 2004 Geometrical Product Specifications (GPS) - Geometrical tolerancing - Tole
19、rances of form, orientation, location and run-out EN ISO 1101 - 2 60086-2 IEC:2011 CONTENTS FOREWORD . 4 INTRODUCTION . 6 1 Scope . 7 2 Normative references . 7 3 Terms, definitions, symbols and abbreviations 7 3.1 Terms and definitions 7 3.2 Symbols and abbreviations 8 4 Battery dimensions, symbols
20、 9 5 Constitution of the battery specification tables 9 6 Physical and electrical specifications 11 6.1 Category 1 batteries 11 6.1.1 Category 1 Physical and electrical specifications 11 6.2 Category 2 batteries 18 6.2.1 Category 2 Physical and electrical specifications 18 6.3 Category 3 batteries 2
21、0 6.3.1 Category 3 Physical and electrical specifications 20 6.4 Category 4 batteries 21 6.4.1 Category 4 Physical and electrical specifications 21 6.5 Category 5 batteries 30 6.5.1 Category 5 Physical and electrical specifications 30 6.6 Category 6 batteries 34 6.6.1 Category 6 Physical and electri
22、cal specifications 34 Annex A (informative) Tabulation of batteries by application 48 Annex B (informative) Cross-reference index . 54 Annex C (informative) Index . 57 Annex D (informative) Common designation 58 Bibliography 59 Figure 1 Category 1 dimensional drawings . 11 Figure 2 Category 2 dimens
23、ional drawing 18 Figure 3 Category 3 dimensional drawings . 20 Figure 4 Category 4 dimensional drawing 21 Figure 5 Gauge drawing for P system batteries 24 Figure 6 Airhole placement diagram . 25 Figure 7 Dimensional drawings: R40 30 Figure 8 Dimensional drawing: 4LR44, 2CR13252, 4SR44 . 32 Figure 9
24、Dimensional drawings: 3R12P, 3R12S, 3LR12 . 34 Figure 10 Dimensional drawings: 4LR61 36 Figure 11 Dimensional drawings: CR-P2 37 Figure 12 Dimensional drawings: 2CR5 . 38 Figure 13 Dimensional drawings: 2EP3863 39 Figure 14 Dimensional drawings: 4R25X, 4LR25X . 40 Figure 15 Dimensional drawings: 4R2
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN6008622011ENPRIMARYBATTERIESPART2PHYSICALANDELECTRICALSPECIFICATIONSREMAINSCURRENT 原电池 部分 物理 电气 规范

链接地址:http://www.mydoc123.com/p-717592.html