《DLA MIL-DTL-24558 18 B-2011 TERMINAL BOXES CONNECTION SUBMERSIBLE (15-FOOT) 600 VOLTS 4-TERMINAL 8-WIRE SYMBOLS NO 400 1 AND NO 400 4 4-TERMINAL 12-WIRE SYMBOLS NO 400 2 AND NO 400.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-DTL-24558 18 B-2011 TERMINAL BOXES CONNECTION SUBMERSIBLE (15-FOOT) 600 VOLTS 4-TERMINAL 8-WIRE SYMBOLS NO 400 1 AND NO 400 4 4-TERMINAL 12-WIRE SYMBOLS NO 400 2 AND NO 400.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、AMSC N/A FSC 5940 INCH-POUND MIL-DTL-24558/18B 3 October 2011 SUPERSEDING MIL-DTL-24558/18A w/AMENDMENT 1 17 February 2006 DETAIL SPECIFICATION SHEET TERMINAL BOXES, CONNECTION, SUBMERSIBLE (15-FOOT), 600 VOLTS, 4-TERMINAL, 8-WIRE, SYMBOLS NO. 400.1 AND NO. 400.4, 4-TERMINAL, 12-WIRE, SYMBOLS NO. 40
2、0.2 AND NO. 400.3 This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the products described herein shall consist of this specification sheet and MIL-DTL-24558, “Terminal Boxes, Connection, for Electrical and Electronic
3、Systems, General Specification for“. REQUIREMENTS: The terminal boxes shall be as specified herein and in accordance with tables I and II, and figures 1 through 3. 1. Electrical rating. The terminal boxes shall have an electrical rating of 600 volts root mean square, and 600 volts direct current. Th
4、e maximum current shall not exceed 15 amperes per stud of terminal board. 2. Dimensions and configuration. For dimensions and configuration see figures 1 through 3. All dimensions in figures 1 through 3 are expressed in decimal inches. Overall terminal box dimensions are approximate. Exact dimension
5、s are shown in MIL-E-24142/5, “Enclosure for Electrical Fittings and Fixtures, Submersible, (15-Foot), Sizes 3R, 4R and 5R“, and in MIL-E-24142/11, “Enclosures-Plastic, Submersible, (15-Foot) 3 and 4 - Inches Round, Grounded“. 3. Tolerance. All tolerances not specified herein shall be in accordance
6、with MIL-DTL-24558. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24558/18B 2 4. Standard parts. The standard parts shown in table I shall be used in the construction of the connection boxes specified herein. The numbers in circles shown on
7、 figures 1 and 2 are the same as those shown in the “Item“ column of table I. 5. Enclosure. The enclosures shall be a 15-foot submersible type. 6. Finish. The interior of the enclosures may be painted or left unpainted at the contractors option. 7. Weight. The weight of the connection boxes shall no
8、t exceed the following: Symbol number 400.1 - 2.0 pounds Symbol number 400.3 - 3.0 pounds Symbol number 400.2 - 3.0 pounds Symbol number 400.4 - 2.0 pounds QUALITY ASSURANCE: First article inspection and quality conformance inspection shall be as specified in MIL-DTL-24558. NOTES: 1. Drawing. The te
9、rminal boxes specified by this specification sheet were formerly covered on NAVSHIPS drawing no. 9000-S6202-74027. 2. Part or identifying number (PIN). The PIN to be used for terminal boxes acquired to this specification is created as follows: M 24558/18 - XXXX Symbol number (see table II) Specifica
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL2455818B2011TERMINALBOXESCONNECTIONSUBMERSIBLE15FOOT600VOLTS4TERMINAL8WIRESYMBOLSNO4001ANDNO40044TERMINAL12WIRESYMBOLSNO4002ANDNO400PDF

链接地址:http://www.mydoc123.com/p-690197.html