DLA DSCC-DWG-84148 REV E-2005 CONNECTORS PLUGS AND RECEPTACLES ELECTRICAL COAXIAL TWINAXIAL AND TRIAXIAL RADIO FREQUENCY《射频的 双轴和三轴电缆的电子储器和插头的连接器》.pdf
《DLA DSCC-DWG-84148 REV E-2005 CONNECTORS PLUGS AND RECEPTACLES ELECTRICAL COAXIAL TWINAXIAL AND TRIAXIAL RADIO FREQUENCY《射频的 双轴和三轴电缆的电子储器和插头的连接器》.pdf》由会员分享,可在线阅读,更多相关《DLA DSCC-DWG-84148 REV E-2005 CONNECTORS PLUGS AND RECEPTACLES ELECTRICAL COAXIAL TWINAXIAL AND TRIAXIAL RADIO FREQUENCY《射频的 双轴和三轴电缆的电子储器和插头的连接器》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、REV STATUS CHECKED BY Clarence Brezius APPROVEDBY L. Olzsewski SIZE CAGE CODE 03723 REV E A I TITLE CONNECTORS, PLUGS AND RECEPTACLES, ELECTRICAL, COAXIAL, TWINAXIAL AND TRIAXIAL, RADIO FREQUENCY 841 48 DWG. NO. PAGE 1 OF 6 Original date of drawing 5 November 1984 PREPARED BY Ron Gary DEFENSE SUPPLY
2、 CENTER, COLUMBUS 1 COLUMBUS, OHIO 43218-3990 AMSC NIA 5935-E753 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1 .I Scope. This drawing covers the general requirements and tests for radio frequency connectors used with flexible RF cables and certai
3、n other types of coaxial transmission lines. 1.2 Part or Identifvinci Number (PIN). The complete PIN shall be as specified on the requirements drawing and constructed using the following format: xxxxx IL DSCC Connector Material i Finish 4 Cable requirement series (1.2.3) (1.2.4) accommodation s draw
4、ing (1.2.2) (1.2.5) (1.2.1) 1.2.1 DSCC requirements drawing. The DSCC requirements drawing shall state the requirement values and design modifications required of the connectors to be procured by the Government. 1.2.2 Connector series. The connector series shall be identified in the following manner
5、: (Interfaces shall be in accordance with MIL-STD-348.) Desiqnation Series N N C C B BNC T TNC M SMB D SMC S SMA Z Defined on the requirements drawing 1.2.3 Material. Connector body material shall be identified in the following manner: I .2.4 Finish. Connector body finish material shall be identifie
6、d in the following manner: CAGE CODE DWG NO. 03723 841 48 A DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 4321 8-3990 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1 1.2.5 Cable accommodation. Connectors shall accommodate cables as specified in the
7、requirements drawing. Accommodations shall be identified in the following manner: Example: A - -_ MI 7/133-RG405 B - -_-_ M 17/113-RG316 2. APPLICABLE DOCUMENTS 2.1 Government document. 2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part o
8、f this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-DTL-3655 MIL-PRF-39012 - Connectors, Coaxial, Radio Frequency, General Specification For. MIL-PRF-49142
9、- Connectors, Triaxial, Radio Frequency, General Specification For. MIL-C-83517 - Connectors, Plug and Receptacle, Electrical (Coaxial Series Twin) and Associated Fittings, General Specification For. - Connector, Coaxial, Radio Frequency for Coaxial, Strip or Microstrip Transmission Line, General Sp
10、ecification For. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-202 - Test Methods for Electronic and Electrical Component Parts. MIL-STD-348 - Interface standard, Radio Frequency, Connector, Interfaces For. (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ or http:/
11、assist.daps.dla.mil or from the Standardization Documents Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 191 11-5094.) 3. REQUIREMENTS 3.1 DSCC requirements drawing. The individual item requirements shall be in accordance with the applicable specification listed in 2.1, except as spec
12、ified in the requirements drawing and herein. In case of conflict between this drawing and the requirements drawing, the latter shall govern. 3.2 Desiqn, construction. and physical dimensions. The design, construction, and physical dimensions shall be as specified in the applicable specification lis
13、ted in 2.1, except as specified in the requirements drawing and herein. 3.2.1 Desiqn documentation. The design documentation shall be in accordance with the applicable specification listed in 2.1, and unless otherwise specified in the acquisition document, shall be retained by the manufacturer but b
14、e available for review by the contracting activity or contractor upon request. 3.3 Electrical Derformance characteristics. The electrical performance characteristics are as specified in table I and the requirements drawing and apply over the entire operating temperature, unless otherwise specified.
15、3.4 Marking. Marking shall be in accordance with the applicable specification listed in 2.1, except the PIN shall be in accordance with 1.2 herein. CAGE CODE DWG NO. A DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 Provided by IHSNot for ResaleNo reproduction or networking permitted without
16、 license from IHS-,-,-3.5 Quality assurance requirements. Connectors furnished under this drawing shall have been subjected to, and passed all the requirements, tests, and inspections detailed herein including quality conformance inspections. TABLE I. Electrical performance characteristics. Examinat
17、ion or test Examination or test I Requirements value IR Ilnsulation resistance) I 5.000 meaohms Requirement value 3.6 Environmental and mechanical performance characteristics. The environmental and mechanical performance characteristics are as specified in table II. TABLE II. Environmental and mecha
18、nical performance characteristics. Corrosion Durability 48 hrs, 5% salt solution (MIL-STD-202, method 101) 500 cycles 3.7 Qualification. Qualification inspection for connectors specified herein shall not be required. 3.7.1 Qualitv conformance inspection. Quality conformance inspection shall be in ac
19、cordance with the applicable specification listed in 2.1 and 4.3 herein. 3.8 Certification as an approved source of supply. In order to be listed as an approved source of supply for connectors manufactured to this drawing, a manufacturer shall: a. Agree to make available to DSCC, upon request, all p
20、ertinent test data on its production of the subject part. b. Provide to DSCC-VAI or its designated agent, upon request, free of change and without obligation, a current production sample from its production of the subject part. c. Meet one of the following criteria: (1) Currently possess part I list
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLADSCCDWG84148REVE2005CONNECTORSPLUGSANDRECEPTACLESELECTRICALCOAXIALTWINAXIALANDTRIAXIALRADIOFREQUENCY

链接地址:http://www.mydoc123.com/p-688771.html